cpqFcaAccelErrCode

CPQFCA-MIB · .1.3.6.1.4.1.232.16.2.2.2.1.5

Object

column mandatory Enumeration
Array Accelerator Board Error Code.
              
Use this to determine the status of the write cache operations.
              
The status can be:
              
Other (1)
  Indicates that the instrument agent does not recognize the
  error code.  You may need to update your software.
              
Invalid (2)
  Indicates that write cache operations are currently
  configured and enabled for at least one logical drive.
  No write cache errors have occurred.
              
Bad Configuration (3)
  Indicates that write cache operations are temporarily
  disabled.  The Array Accelerator board was configured for a
  different controller.  This error could be caused if boards
  were switched from one system to another.  Rerun the
  configuration utility and ensurethat the board has been
  properly configured for this system.
              
Low Battery Power (4)
  Indicates that write cache operations are temporarily
  disabled due to insufficient battery power.  Please view
  the Battery Status object instance for more information.
              
Disable Command Issued (5)
  Indicates that write cache operations are temporarily
  disabled.  The device driver issues this command when
  the server is taken down.  This condition should not
  exist when the system regains power.
              
No Resources Available (6)
  Indicates that write cache operations are temporarily
  disabled.  The controller does not have sufficient
  resources to perform write cache operations.
  For example, when a replaced drive is being rebuilt,
  there will not be sufficient resources.  Once the
  operation that requires the resources has completed,
  this condition will clear and write cache operations
  will resume.
              
Board Not Connected (7)
  Indicates that write cache operations are temporarily
  disabled.  The Array Accelerator board has been
  configured but is not currently attached to the
  controller. Check the alignment of the board and
  connections.
              
Bad Mirror Data (8)
  Indicates that write cache operations have been
  permanently disabled.  The Array Accelerator board stores
  mirrored copies of all data.  If data exists on the
  board when the system is first powered up, the board
  performs a data compare test between the mirrored copies.
  If the data does not match, an error has occurred.
  Data may have been lost.  Your board may need servicing.
              
Read Failure (9)
  Indicates that write cache operations have been permanently
  disabled.  The Array Accelerator board stores mirror copies
  of all data.  While reading the data from the board, memory
  parity errors have occurred.  Both copies were corrupted and
  cannot be retrieved.  Data has been lost, and you should
  service the board.
              
Write Failure (10)
  Indicates that write cache operations have been permanently
  disabled.  This error occurs when an unsuccessful attempt was
  made to write data to the Array Accelerator board.  Data could
  not be written to write cache memory in duplicate due to the
  detection of parity errors.  This error does not indicate data
  loss.  You should service the Array Accelerator board.
              
Config Command (11)
  Indicates that write cache operations have been permanently
  disabled.  The configuration of the logical drives has changed.
  You need to reconfigure the Array Accelerator board.
              
Expand In Progress (12)
  Indicates that cache operations are temporarily disabled
  due to an expand of a logical drive.  When the expand
  operation completes, the accelerator will be enabled.
              
Snapshot In Progress (13)
  Indicates that cache operations are temporarily disabled
  due to a snapshot operation that is queued up or in progress.
  When the snapshot operation completes, the accelerator will
  be enabled.
              
Redundant Low Battery (14)
  Indicates that cache operations are temporarily disabled.
  The redundant controller has insufficient cache battery power.
              
Redundant Size Mismatch (15)
  Indicates that cache operations are temporarily disabled.
  The cache sizes on the redundant controllers do not match.
              
Redundant Cache Failure (16)
  Indicates that cache operations are temporarily disabled.
  The cache on the redundant controller has failed.
              
Excessive ECC Errors (17)
  Indicates that write cache operations have been permanently
  disabled.  The number of cache lines experiencing excessive
  ECC errors has reached a preset limit.
              
Power On Self Test (Post) ECC Errors (19)
  Indicates that write cache operations have been permanently
  disabled.  The cache has been disabled due to a large number
  of ECC errors detected while testing the cache during Power
  On Self Test (Post).

Context

MIB
CPQFCA-MIB
OID
.1.3.6.1.4.1.232.16.2.2.2.1.5
Type
column
Access
readonly
Status
mandatory
Parent
cpqFcaAccelEntry
Table
cpqFcaAccelTable
Siblings
13

Syntax

Enumeration

Values & Constraints

Enumerated Values
1other
2invalid
3badConfig
4lowBattery
5disableCmd
6noResources
7notConnected
8badMirrorData
9readErr
10writeErr
11configCmd
12expandInProgress
13snapshotInProgress
14redundantLowBattery
15redundantSizeMismatch
16redundantCacheFailure
17excessiveEccErrors
19postEccErrors

Related Objects