cpqFcaAccelBatteryStatus

CPQFCA-MIB · .1.3.6.1.4.1.232.16.2.2.2.1.6

Object

column mandatory Enumeration
Array Accelerator Board Battery Status.
              
This monitors the status of each battery pack on the board.  The
batteries can only recharge when the system has power applied.
              
The following values are valid:
              
Other (1)
  Indicates that the instrument agent does not recognize
  battery status.  You may need to update your software.
              
Ok (2)
  Indicates that a particular battery pack is fully charged.
              
Charging (3)
  The battery power is less than 75%.  The array controller
  is attempting to recharge the battery.  A battery can take
  as long as 36 hours to fully recharge.  After 36 hours,
  if the battery has not recharged, it is considered failed.
              
Failed (4)
  The battery pack is below the sufficient voltage level and
  has not recharged in 36 hours.  Your Array Accelerator board
  needs to be serviced.
              
Degraded (5)
  The battery is still operating, however, one of the batteries
  in the pack has failed to recharge properly.  Your Array
  Accelerator board should be serviced as soon as possible.
              
NotPresent (6)
  There are no batteries associated with this controller.

Context

MIB
CPQFCA-MIB
OID
.1.3.6.1.4.1.232.16.2.2.2.1.6
Type
column
Access
readonly
Status
mandatory
Parent
cpqFcaAccelEntry
Table
cpqFcaAccelTable
Siblings
13

Syntax

Enumeration

Values & Constraints

Enumerated Values
1other
2ok
3recharging
4failed
5degraded
6notPresent

Related Objects