fanTwoStatus
CONTIVITY-TRAPS-V1-MIB ·
.1.3.6.1.4.1.2505.1.1.7
Object
scalar
RFC1213-MIBDisplayString
Status of the second CPU fan
Possible Values:
Alert: CPU Two Fan: Fan not functioning;
This indicates that the fan on the auxiliary processor is
running either below the specified speed or not running
at all. If a fan is not working correctly, it must be
fixed as soon as possible or damage may result.
This is a high priority event which can prove catastrophic
to the processor as well as the system. This trap can only
be sent by systems which contain an actual fan on the
auxiliary CPU.
Context
- MIB
- CONTIVITY-TRAPS-V1-MIB
- OID
.1.3.6.1.4.1.2505.1.1.7- Type
- scalar
- Access
- readonly
- Status
- current
- Parent
- hardwareCESTrapInfo
- Siblings
- 25
Syntax
RFC1213-MIBDisplayString
- Source
- RFC1213-MIBDisplayString
- Base type
OctetString
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| hardDisk1Status Hard Disk Number 1 Status.
Possible Values:
Warning: Hard Disk 1 : Device /ide1/ not available
Warning: Hard Disk 1 : Utilization exceeds 75%% on /ide1/
Alert: Hard Disk 1 : Util… | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.2505.1.1.1 |
| fiveVoltsMinus Status of -5 Volt power.
Possible Values:
Alert: Voltage 5 V Minus: Voltage out of range;
The supplied voltage to the system is not within the
the specified… | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.2505.1.1.10 |
| threeVoltsPositive Status of +3 Volt power.
Possible Values:
Alert: Voltage 3.3 V Plus: Voltage out of range;
The supplied voltage to the system is not within the
the specifie… | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.2505.1.1.11 |
| twoDotFiveVA Status of 2.5VA power.
Possible Values:
Alert: Voltage 2.5 VA: Voltage out of range;
This is the voltage supplied to the primary processor.
The supplied vol… | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.2505.1.1.12 |
| twoDotFiveVB Status of 2.5VB power.
Possible Values:
Alert: Voltage 2.5 VB: Voltage out of range;
This is the voltage supplied to the seconary processor.
The supplied vo… | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.2505.1.1.13 |
| twelveVoltsPositive Status of +12 Volt power.
Possible Values:
Alert: Voltage 12 V Plus: Voltage out of range;
The supplied voltage to the system is not within the
the specifie… | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.2505.1.1.14 |
| twelveVoltsMinus Status of -12 Volt power.
Possible Values:
Alert: Voltage 12 V Minus: Voltage out of range;
The supplied voltage to the system is not within the
the specifi… | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.2505.1.1.15 |
| normalTemperature Status of normal temperature reading.
Possible Values:
Alert: Normal Temperature: Normal temperature out of range;
This indicates that the box is running above … | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.2505.1.1.16 |
| criticalTemperature Status of critical temperature reading.
Possible Values:
Alert: Critical Temperature: Critial temperature out of range;
This indicates that the box is running a… | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.2505.1.1.17 |
| chassisIntrusion The chassis intrusion sensor indicates that the unit has been opened.
Possible Values:
Alert: Intrusion: Box has been opened;
The cover to the CES ha… | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.2505.1.1.18 |
| dualPowerSupply Status of the redundant power supplies.
Possible Values:
Alert: Dual Power Supply: Redundant supply faulted
This indicates that, on systems with redundant power… | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.2505.1.1.19 |
| hardDisk0Status Hard Disk Number 0 Status.
Possible Values:
Warning: Hard Disk 0 : Device /ide0/ not available
Warning: Hard Disk 0 : Utilization exceeds 75%% on /ide0/
Alert: Hard Disk 0 : Util… | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.2505.1.1.2 |
| t1WANStatus Status of T1 WAN card(s).
Possible Values:
For Wanic support:
Alert: Invalid Device X
Warning: Device WanicX disabled
Alert: Device WanicX down
W… | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.2505.1.1.20 |
| t3WANStatus Status of T3 WAN card
Possible Values:
Alert: Invalid Index X
Warning: Device HSSIX disabled
Alert: Device HSSIX down
Warning: Device HSSIX not initialized
Alert: Device HSSIX PPP… | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.2505.1.1.21 |
| hwAccelStatus Status of hardware accelerator card. | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.2505.1.1.22 |
| v90WANStatus Status of V.90 Interface card
Possible Values:
Please note that X corresponds to the unit number of the card.
Alert: V.90 Invalid index X
Disabled: Device IntModem-X disabled
He… | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.2505.1.1.24 |
| briWANStatus Status of ISDN BRI Interface card
Possible Values:
Please note that X corresponds to the unit number of the card.
Alert: BRI Invalid index X
Alert: Device BRI-X not Responding. … | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.2505.1.1.25 |
| serUartStatus Status of Serial (COM) port/interface
Possible Values:
Please note that X corresponds to the unit number of the serial interface
Alert: COM port Invalid index X
Healthy: Device … | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.2505.1.1.26 |
| adslWANStatus Status of ADI ADSL card
Possible Values:
Please note that X corresponds to the unit number of the serial interface
Alert: Invalid index X
Alert: Device ADIADSLX off line
Disable… | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.2505.1.1.27 |
| memoryUsage Memory Usage Status.
Possible Values:
Warning: Memory Usage : Utilization exceeds 75%
Alert: Memory Usage : Utilization exceeds 87.5% | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.2505.1.1.3 |
| lanCardStatus Status of any LAN cards on the system.
Possible Values:
Please note that X corresponds to the Xth slot in the system.
Please note that Y corresponds to the relative positi… | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.2505.1.1.4 |
| cpuTwoStatus Status of second CPU.
Possible Values:
Alert: CPU 2: Program load failed;
Alert: CPU 2: Bootup did not complete;
Alert: CPU 2: Communication lost;
Alert: CPU 2: Failed. Reason unk… | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.2505.1.1.5 |
| fanOneStatus Status of the first CPU fan.
Possible Values:
Alert: CPU One Fan: Fan not functioning;
This indicates that the fan on the primary processor is
running either below the … | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.2505.1.1.6 |
| chassisFanStatus Status of the chassis fan.
Possible Values:
Alert: Chassis Fan: Fan not functioning;
Alert: Chassis Fan 2: Fan not functioning;
This indicates that one of t… | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.2505.1.1.8 |
| fiveVoltsPositive Status of +5 Volt power.
Possible Values:
Alert: Voltage 5 V Plus: Voltage out of range;
The supplied voltage to the system is not within the
the specified … | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.2505.1.1.9 |
Notification Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| RFC1213-MIBifIndex mandatory A unique value for each interface. Its value
ranges between 1 and the value of ifNumber. The
value for each interface must remain constant at
least from one re-initialization of… | column | Integer32 | .1.3.6.1.2.1.2.2.1.1 |
| RFC1213-MIBifAdminStatus mandatory The desired state of the interface. The
testing(3) state indicates that no operational
packets can be passed. | column | Enumeration | .1.3.6.1.2.1.2.2.1.7 |
| RFC1213-MIBifOperStatus mandatory The current operational state of the interface.
The testing(3) state indicates that no operational
packets can be passed. | column | Enumeration | .1.3.6.1.2.1.2.2.1.8 |
| RFC1213-MIBifDescr mandatory A textual string containing information about the
interface. This string should include the name of
the manufacturer, the product name and the version
of the hardware interface. | column | OctetString | .1.3.6.1.2.1.2.2.1.2 |
| RFC1213-MIBifType mandatory The type of interface, distinguished according to
the physical/link protocol(s) immediately `below'
the network layer in the protocol stack. | column | IANAifType-MIBIANAifType | .1.3.6.1.2.1.2.2.1.3 |
| ifReasonForStatus-ces The reason for the status change. These include:
unknown(1) -- the reason could not be determined.
timed-out(2) -- connection(tunne… | scalar | IfReasonForStatus-ces | .1.3.6.1.4.1.2505.1.14.2.1 |
| ifPhysLocation-ces The physical location of the port. This has the values of
motherBoardOrSlot0, slot1, slot2, slot3, slot4, slot5. | scalar | PortLocation-ces | .1.3.6.1.4.1.2505.1.14.2.2 |
| ifPhysRelPos-ces The relative position of the physical port at the
location defined by interfacePhysLocation. | scalar | Integer32 | .1.3.6.1.4.1.2505.1.14.2.3 |
| ifIpAddr-ces For physical ports this is the associated IP address.
For a tunnel connection it is the local IP address. | scalar | RFC1155-SMIIpAddress | .1.3.6.1.4.1.2505.1.14.2.4 |
| ifName-ces The name of the interface, same as ifName. | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.2505.1.14.2.5 |
| ifTunnelRemoteIpAddr-ces The remote IP address of a tunnel connection. | scalar | RFC1155-SMIIpAddress | .1.3.6.1.4.1.2505.1.14.2.6 |
| RFC1213-MIBsysObjectID mandatory The vendor's authoritative identification of the
network management subsystem contained in the
entity. This value is allocated within the SMI
enterprises subtree (1.3.6.1.4.1) an… | scalar | ObjectIdentifier | .1.3.6.1.2.1.1.2 |
| RFC1213-MIBsysName mandatory An administratively-assigned name for this
managed node. By convention, this is the node's
fully-qualified domain name. | scalar | OctetString | .1.3.6.1.2.1.1.5 |