cpuTwoStatus
CONTIVITY-TRAPS-V1-MIB ·
.1.3.6.1.4.1.2505.1.1.5
Object
scalar
RFC1213-MIBDisplayString
Status of second CPU.
Possible Values:
Alert: CPU 2: Program load failed;
Alert: CPU 2: Bootup did not complete;
Alert: CPU 2: Communication lost;
Alert: CPU 2: Failed. Reason unknown;
Each of these indicates that the application CPU is
not functioning correctly. The system will continue to
function without the application processor. This can only
be sent from a system with multiple CPUs. See the Admin
Guide for a list of systems that contain multiple CPUs.
The CES will emit an audible alarm and the networking
performance will be degraded. A Nortel support
representative should be contacted if rese ing the CES
does not correct the problem.
The effect is the same in each case. The system will be
running with only one CPU.
Context
- MIB
- CONTIVITY-TRAPS-V1-MIB
- OID
.1.3.6.1.4.1.2505.1.1.5- Type
- scalar
- Access
- readonly
- Status
- current
- Parent
- hardwareCESTrapInfo
- Siblings
- 25
Syntax
RFC1213-MIBDisplayString
- Source
- RFC1213-MIBDisplayString
- Base type
OctetString
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| hardDisk1Status Hard Disk Number 1 Status.
Possible Values:
Warning: Hard Disk 1 : Device /ide1/ not available
Warning: Hard Disk 1 : Utilization exceeds 75%% on /ide1/
Alert: Hard Disk 1 : Util… | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.2505.1.1.1 |
| fiveVoltsMinus Status of -5 Volt power.
Possible Values:
Alert: Voltage 5 V Minus: Voltage out of range;
The supplied voltage to the system is not within the
the specified… | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.2505.1.1.10 |
| threeVoltsPositive Status of +3 Volt power.
Possible Values:
Alert: Voltage 3.3 V Plus: Voltage out of range;
The supplied voltage to the system is not within the
the specifie… | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.2505.1.1.11 |
| twoDotFiveVA Status of 2.5VA power.
Possible Values:
Alert: Voltage 2.5 VA: Voltage out of range;
This is the voltage supplied to the primary processor.
The supplied vol… | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.2505.1.1.12 |
| twoDotFiveVB Status of 2.5VB power.
Possible Values:
Alert: Voltage 2.5 VB: Voltage out of range;
This is the voltage supplied to the seconary processor.
The supplied vo… | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.2505.1.1.13 |
| twelveVoltsPositive Status of +12 Volt power.
Possible Values:
Alert: Voltage 12 V Plus: Voltage out of range;
The supplied voltage to the system is not within the
the specifie… | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.2505.1.1.14 |
| twelveVoltsMinus Status of -12 Volt power.
Possible Values:
Alert: Voltage 12 V Minus: Voltage out of range;
The supplied voltage to the system is not within the
the specifi… | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.2505.1.1.15 |
| normalTemperature Status of normal temperature reading.
Possible Values:
Alert: Normal Temperature: Normal temperature out of range;
This indicates that the box is running above … | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.2505.1.1.16 |
| criticalTemperature Status of critical temperature reading.
Possible Values:
Alert: Critical Temperature: Critial temperature out of range;
This indicates that the box is running a… | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.2505.1.1.17 |
| chassisIntrusion The chassis intrusion sensor indicates that the unit has been opened.
Possible Values:
Alert: Intrusion: Box has been opened;
The cover to the CES ha… | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.2505.1.1.18 |
| dualPowerSupply Status of the redundant power supplies.
Possible Values:
Alert: Dual Power Supply: Redundant supply faulted
This indicates that, on systems with redundant power… | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.2505.1.1.19 |
| hardDisk0Status Hard Disk Number 0 Status.
Possible Values:
Warning: Hard Disk 0 : Device /ide0/ not available
Warning: Hard Disk 0 : Utilization exceeds 75%% on /ide0/
Alert: Hard Disk 0 : Util… | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.2505.1.1.2 |
| t1WANStatus Status of T1 WAN card(s).
Possible Values:
For Wanic support:
Alert: Invalid Device X
Warning: Device WanicX disabled
Alert: Device WanicX down
W… | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.2505.1.1.20 |
| t3WANStatus Status of T3 WAN card
Possible Values:
Alert: Invalid Index X
Warning: Device HSSIX disabled
Alert: Device HSSIX down
Warning: Device HSSIX not initialized
Alert: Device HSSIX PPP… | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.2505.1.1.21 |
| hwAccelStatus Status of hardware accelerator card. | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.2505.1.1.22 |
| v90WANStatus Status of V.90 Interface card
Possible Values:
Please note that X corresponds to the unit number of the card.
Alert: V.90 Invalid index X
Disabled: Device IntModem-X disabled
He… | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.2505.1.1.24 |
| briWANStatus Status of ISDN BRI Interface card
Possible Values:
Please note that X corresponds to the unit number of the card.
Alert: BRI Invalid index X
Alert: Device BRI-X not Responding. … | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.2505.1.1.25 |
| serUartStatus Status of Serial (COM) port/interface
Possible Values:
Please note that X corresponds to the unit number of the serial interface
Alert: COM port Invalid index X
Healthy: Device … | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.2505.1.1.26 |
| adslWANStatus Status of ADI ADSL card
Possible Values:
Please note that X corresponds to the unit number of the serial interface
Alert: Invalid index X
Alert: Device ADIADSLX off line
Disable… | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.2505.1.1.27 |
| memoryUsage Memory Usage Status.
Possible Values:
Warning: Memory Usage : Utilization exceeds 75%
Alert: Memory Usage : Utilization exceeds 87.5% | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.2505.1.1.3 |
| lanCardStatus Status of any LAN cards on the system.
Possible Values:
Please note that X corresponds to the Xth slot in the system.
Please note that Y corresponds to the relative positi… | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.2505.1.1.4 |
| fanOneStatus Status of the first CPU fan.
Possible Values:
Alert: CPU One Fan: Fan not functioning;
This indicates that the fan on the primary processor is
running either below the … | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.2505.1.1.6 |
| fanTwoStatus Status of the second CPU fan
Possible Values:
Alert: CPU Two Fan: Fan not functioning;
This indicates that the fan on the auxiliary processor is
running either below th… | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.2505.1.1.7 |
| chassisFanStatus Status of the chassis fan.
Possible Values:
Alert: Chassis Fan: Fan not functioning;
Alert: Chassis Fan 2: Fan not functioning;
This indicates that one of t… | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.2505.1.1.8 |
| fiveVoltsPositive Status of +5 Volt power.
Possible Values:
Alert: Voltage 5 V Plus: Voltage out of range;
The supplied voltage to the system is not within the
the specified … | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.2505.1.1.9 |