WebGraph-AnalogIO-57762-US-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
10
Rows
10
Columns
100
.1.3.6.1.4.1.5040.1.2.29.1.2
·
1 row entry
·
1 columns
List of sensors.
List of sensor numbers.
Indexes
wtWebGraphAnalog57762SensorNo
| Column | Syntax | OID |
|---|---|---|
|
wtWebGraphAnalog57762SensorNo
mandatory
Sensor number.
|
Integer32 Constraints: range: 1-2 |
.1.3.6.1.4.1.5040.1.2.29.1.2.1.1 |
.1.3.6.1.4.1.5040.1.2.29.1.3
·
1 row entry
·
1 columns
List of measurement values corresponding to the channel numbers.
Measurement values of the sensors.
Indexes
wtWebGraphAnalog57762SensorNo
| Column | Syntax | OID |
|---|---|---|
|
wtWebGraphAnalog57762Values
mandatory
Measurement value of the sensor, ASCII.
This value will be translated according to the ports settings for the read and write operations. |
OctetStringr/w Constraints: range: 5-5 |
.1.3.6.1.4.1.5040.1.2.29.1.3.1.1 |
.1.3.6.1.4.1.5040.1.2.29.1.4
·
1 row entry
·
1 columns
List of binary measurement values corresponding to the channel numbers.
Binary measurement values of the sensors.
Indexes
wtWebGraphAnalog57762SensorNo
| Column | Syntax | OID |
|---|---|---|
|
wtWebGraphAnalog57762BinaryValues
mandatory
Binary measurement value of the sensor in 1/1000,
signed number, 0x7FFFFFFF indicates an invalid value. This value will be translated according to the ports settings for the read and write operations. |
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.5040.1.2.29.1.4.1.1 |
.1.3.6.1.4.1.5040.1.2.29.1.8
·
1 row entry
·
1 columns
List of measurement values corresponding to the channel numbers.
Measurement values of the sensors.
Indexes
wtWebGraphAnalog57762SensorNo
| Column | Syntax | OID |
|---|---|---|
|
wtWebGraphAnalog57762ValuesPoint
mandatory
Measurement value of the sensor, ASCII.
This value will be translated according to the ports settings for the read and write operations. |
OctetStringr/w Constraints: range: 5-5 |
.1.3.6.1.4.1.5040.1.2.29.1.8.1.1 |
.1.3.6.1.4.1.5040.1.2.29.3.1.3.9.2
·
1 row entry
·
1 columns
Table of indices.
Indices of the binary channels.
Indexes
wtWebGraphAnalog57762BinaryModeNo
| Column | Syntax | OID |
|---|---|---|
|
wtWebGraphAnalog57762BinaryModeNo
mandatory
Number of the binary channel.
|
Integer32 Constraints: range: 1-2 |
.1.3.6.1.4.1.5040.1.2.29.3.1.3.9.2.1.1 |
.1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3
·
1 row entry
·
29 columns
Table of properties of the binary mode.
Binary properties.
Indexes
wtWebGraphAnalog57762BinaryModeNo
| Column | Syntax | OID |
|---|---|---|
|
wtWebGraphAnalog57762BinaryOperationMode
mandatory
Selection of the operation mode:
The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : UDP Peer Bit 1 : TCP Client … |
OctetStringr/w Constraints: range: 4-4 |
.1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.1 |
|
wtWebGraphAnalog57762BinaryTcpServerLocalPort
mandatory
Local TCP port for data exchange in this server mode.
This port number must be unique within the device. Reserved port number must not be used (refere to the manual). |
Integer32r/w Constraints: range: 1-65535 |
.1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.2 |
|
wtWebGraphAnalog57762BinaryTcpServerInputTrigger
mandatory
Every change on the inputs causes their state to be transmitted to the
remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input … |
OctetStringr/w Constraints: range: 4-4 |
.1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.3 |
|
wtWebGraphAnalog57762BinaryTcpServerApplicationMode
mandatory
Selection of the application mode:
The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 4-7: unused Bit 3 : OPC Device Bit 2 : Box2Box S… |
OctetStringr/w Constraints: range: 4-4 |
.1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.4 |
|
wtWebGraphAnalog57762BinaryTcpClientLocalPort
mandatory
Local TCP port for data exchange in this client mode.
This port number must be unique within the device. Reserved port number must not be used (refere to the manual). |
Integer32r/w Constraints: range: 1-65535 |
.1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.5 |
|
wtWebGraphAnalog57762BinaryTcpClientServerPort
mandatory
Port number of the server. A complete set of port number, IP address
and a valid input/output mask starts this mode. No data exchange take place when setting the server port to zero. |
Integer32r/w Constraints: range: 1-65535 |
.1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.6 |
|
wtWebGraphAnalog57762BinaryTcpClientServerIpAddr
mandatory
Ip address of the server. A complete set of port number, IP address
and a valid input/output mask starts this mode. No data exchange take place when setting the server IP address to 0.0.0.0. |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.7 |
|
wtWebGraphAnalog57762BinaryTcpClientServerPassword
mandatory
Building a connection may be protected by the
administrator password of the server. Enter the server password to establish the connection, if a server administrator password exists. |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.8 |
|
wtWebGraphAnalog57762BinaryTcpClientInactivity
mandatory
Connection timeout in 100ms. If no data are exchanged within the specified
time, the device closes the connection to the server. The value 0 deactivates the timer. Using the Box2Box mode this function is disabled. |
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.9 |
|
wtWebGraphAnalog57762BinaryTcpClientInputTrigger
mandatory
Every change on the inputs causes their state to be transmitted to the
remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input … |
OctetStringr/w Constraints: range: 4-4 |
.1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.10 |
|
wtWebGraphAnalog57762BinaryTcpClientInterval
mandatory
Configurable interval with a 100ms base, in which the Webio device sends
data to the configured application. A interval of zero stopps the periodical sending. |
Integer32r/w Constraints: range: 0-65535 |
.1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.11 |
|
wtWebGraphAnalog57762BinaryTcpClientApplicationMode
mandatory
Selection of the application mode:
The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : Box2Box Slave Bit 1 : Compat… |
OctetStringr/w Constraints: range: 4-4 |
.1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.12 |
|
wtWebGraphAnalog57762BinaryUdpPeerLocalPort
mandatory
Local UDP port for data exchange in this peer to peer mode.
This port number must be unique within the device. Reserved port number must not be used (refere to the manual). |
Integer32r/w Constraints: range: 1-65535 |
.1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.13 |
|
wtWebGraphAnalog57762BinaryUdpPeerRemotePort
mandatory
Port number of the remote device. A complete set of port number, IP address
and a valid input/output mask starts this mode. No data exchange take place when setting the remote port to zero. |
Integer32r/w Constraints: range: 1-65535 |
.1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.14 |
|
wtWebGraphAnalog57762BinaryUdpPeerRemoteIpAddr
mandatory
Ip address of the remote device. A complete set of port number, IP address
and a valid input/output mask starts this mode. No data exchange take place when setting the remote device IP address to 0.0.0.0. |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.15 |
|
wtWebGraphAnalog57762BinaryUdpPeerInputTrigger
mandatory
Every change on the inputs causes their state to be transmitted to the
remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input … |
OctetStringr/w Constraints: range: 4-4 |
.1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.16 |
|
wtWebGraphAnalog57762BinaryUdpPeerInterval
mandatory
Configurable interval with a 100ms base, in which the Webio device sends
data to the configured remote device. A interval of zero stopps the periodical sending. |
Integer32r/w Constraints: range: 0-65535 |
.1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.17 |
|
wtWebGraphAnalog57762BinaryUdpPeerApplicationMode
mandatory
Selection of the application mode:
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused… |
OctetStringr/w Constraints: range: 4-4 |
.1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.18 |
|
wtWebGraphAnalog57762BinaryConnectedPort
mandatory
Port number of the remote device, after connection has been established.
In case of no connection or missing port informations a zero will be read. |
Integer32 Constraints: range: 1-65535 |
.1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.19 |
|
wtWebGraphAnalog57762BinaryConnectedIpAddr
mandatory
IP address of the remote device, after connection has been established.
In case of no connection or missing port informations 0.0.0.0 will be read. |
RFC1155-SMIIpAddress Textual Convention: RFC1155-SMIIpAddress OctetStringType Constraints: range: 4 |
.1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.20 |
|
wtWebGraphAnalog57762BinaryTcpServerClientHttpPort
mandatory
HTTP port number of the remote device at TCP Server Mode. If an mailfunction occurs
status informations will be send to this port. Not used at mode Compatible 50xxx. |
Integer32r/w Constraints: range: 1-65535 |
.1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.21 |
|
wtWebGraphAnalog57762BinaryTcpClientServerHttpPort
mandatory
HTTP port number of the remote device at TCP Client Mode. In the operating mode
Box2Box connection status informations will be exchanged through this port. |
Integer32r/w Constraints: range: 1-65535 |
.1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.22 |
|
wtWebGraphAnalog57762BinaryTcpServerHysteresis1
mandatory
A change greater than this value initiate a transmission of the corresponding input value.
The input 1 must be selected at wtWebGraphAnalog57762BinaryTcpServerInputTrigger. With a hysteresis of zero any change will be t… |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.23 |
|
wtWebGraphAnalog57762BinaryTcpServerHysteresis2
mandatory
A change greater than this value initiate a transmission of the corresponding input value.
The input 2 must be selected at wtWebGraphAnalog57762BinaryTcpServerInputTrigger. With a hysteresis of zero any change will be t… |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.24 |
|
wtWebGraphAnalog57762BinaryTcpClientHysteresis1
mandatory
A change greater than this value initiate a transmission of the corresponding input value.
The input 1 must be selected at wtWebGraphAnalog57762BinaryTcpClientInputTrigger. With a hysteresis of zero any change will be t… |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.25 |
|
wtWebGraphAnalog57762BinaryTcpClientHysteresis2
mandatory
A change greater than this value initiate a transmission of the corresponding input value.
The input 2 must be selected at wtWebGraphAnalog57762BinaryTcpClientInputTrigger. With a hysteresis of zero any change will be t… |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.26 |
|
wtWebGraphAnalog57762BinaryUdpPeerHysteresis1
mandatory
A change greater than this value initiate a transmission of the corresponding input value.
The input 1 must be selected at wtWebGraphAnalog57762BinaryUdpPeerInputTrigger. With a hysteresis of zero any change will be tra… |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.27 |
|
wtWebGraphAnalog57762BinaryUdpPeerHysteresis2
mandatory
A change greater than this value initiate a transmission of the corresponding input value.
The input 2 must be selected at wtWebGraphAnalog57762BinaryUdpPeerInputTrigger. With a hysteresis of zero any change will be tra… |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.28 |
|
wtWebGraphAnalog57762BinaryTcpClientServerUserName
mandatory
Building a connection may be protected by a specific
user name within the server. Enter the user name to establish the connection, if a user name entry exists. |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.29 |
.1.3.6.1.4.1.5040.1.2.29.3.1.5.2
·
1 row entry
·
1 columns
List of alarm indices.
Numbers of the alarms.
Indexes
wtWebGraphAnalog57762AlarmNo
| Column | Syntax | OID |
|---|---|---|
|
wtWebGraphAnalog57762AlarmNo
mandatory
Alarm number.
|
Integer32 Constraints: range: 1-8 |
.1.3.6.1.4.1.5040.1.2.29.3.1.5.2.1.1 |
.1.3.6.1.4.1.5040.1.2.29.3.1.5.3
·
1 row entry
·
49 columns
List of settings depending on the alarm number.
Alarm parameters of the individual alarms.
Indexes
wtWebGraphAnalog57762AlarmNo
| Column | Syntax | OID |
|---|---|---|
|
wtWebGraphAnalog57762AlarmTrigger
mandatory
Binary coded trigger conditions:
Octet 1: unused Octet 2: unused Octet 3: Bit 0: Timer Bit 1: ColdStart Bit 2: WarmStart Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2-7: unused |
OctetStringr/w Constraints: range: 4-4 |
.1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.1 |
|
wtWebGraphAnalog57762AlarmMin1
mandatory
Minimum sensor 1 with maximum 3 decimal places.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.2 |
|
wtWebGraphAnalog57762AlarmMax1
mandatory
Maximum sensor 1 with maximum 3 decimal places.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.3 |
|
wtWebGraphAnalog57762AlarmHysteresis1
mandatory
Reading changes of this size clears the alarm state (MAX-hyst, MIN+hyst.)
with maximum 3 decimal places. |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.4 |
|
wtWebGraphAnalog57762AlarmDelay
mandatory
Alarm will be delayed by setting this time while stable alarm
condition occur (time in minutes). |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.5 |
|
wtWebGraphAnalog57762AlarmInterval
mandatory
Send interval for alarm messages.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.6 |
|
wtWebGraphAnalog57762AlarmEnable
mandatory
Binary coded alarm enable:
Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Mail Enable Bit 1: SNMP Trap enable Bit 2: TCP Client enable |
OctetStringr/w Constraints: range: 4-4 |
.1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.7 |
|
wtWebGraphAnalog57762AlarmEMailAddr
mandatory
E-Mail address for sending the alarm mail to.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.8 |
|
wtWebGraphAnalog57762AlarmMailSubject
mandatory
Subject line for alarm mail.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.9 |
|
wtWebGraphAnalog57762AlarmMailText
mandatory
Alarm mail text: <Mn> provides the current temperature; n = 1..2.
<Z> provides the current time. |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.10 |
|
wtWebGraphAnalog57762AlarmManagerIP
mandatory
Name or IP address of the SNMP Manager which accepts the trap.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.11 |
|
wtWebGraphAnalog57762AlarmTrapText
mandatory
This text is sent in the trap body.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.12 |
|
wtWebGraphAnalog57762AlarmMailOptions
mandatory
Binary coded options:
Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Attach Thermo.csv Enable Bit 1 : CSV-Data_since_last_report Bit 2-7: unused |
OctetStringr/w Constraints: range: 4-4 |
.1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.13 |
|
wtWebGraphAnalog57762AlarmTcpIpAddr
mandatory
Name or IP address of the TCP server which accepts the trap.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.14 |
|
wtWebGraphAnalog57762AlarmTcpPort
mandatory
Port number of the TCP server which accepts the trap.
|
Integer32r/w Constraints: range: 1-65535 |
.1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.15 |
|
wtWebGraphAnalog57762AlarmTcpText
mandatory
This text is sent in the TCP trap body.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.16 |
|
wtWebGraphAnalog57762AlarmClearMailSubject
mandatory
Subject line for alarm clear mail.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.17 |
|
wtWebGraphAnalog57762AlarmClearMailText
mandatory
Alarm clear mail text: <Mn> provides the current temperature; n = 1..2.
<Z> provides the current time. |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.18 |
|
wtWebGraphAnalog57762AlarmClearTrapText
mandatory
This text is sent in the trap body.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.19 |
|
wtWebGraphAnalog57762AlarmClearTcpText
mandatory
This text is sent in the TCP trap body.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.20 |
|
wtWebGraphAnalog57762AlarmMin2
mandatory
Minimum sensor 2 with maximum 3 decimal places.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.21 |
|
wtWebGraphAnalog57762AlarmMax2
mandatory
Maximum sensor 2 with maximum 2 decimal places.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.22 |
|
wtWebGraphAnalog57762AlarmHysteresis2
mandatory
Hysterese rel. sensor 2 with maximum 3 decimal places.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.23 |
|
wtWebGraphAnalog57762AlarmSyslogIpAddr
mandatory
IP address of the syslog server to which the Webio device should send syslog messages.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.24 |
|
wtWebGraphAnalog57762AlarmSyslogPort
mandatory
Port number of the syslog server to which the Webio device should send syslog messages.
|
Integer32r/w Constraints: range: 1-65535 |
.1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.25 |
|
wtWebGraphAnalog57762AlarmSyslogText
mandatory
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
This text appears in the following syslog message body. |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.26 |
|
wtWebGraphAnalog57762AlarmSyslogClearText
mandatory
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
This text appears in the following syslog message body of a alarm clear message. |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.27 |
|
wtWebGraphAnalog57762AlarmFtpDataPort
mandatory
Local data port: 1..65535 or AUTO: the next free port will be assigned.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.28 |
|
wtWebGraphAnalog57762AlarmFtpFileName
mandatory
Name of the file including path informations.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.29 |
|
wtWebGraphAnalog57762AlarmFtpText
mandatory
Message text to store on the FTP server.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.30 |
|
wtWebGraphAnalog57762AlarmFtpClearText
mandatory
Alarm clear message to store on the FTP server.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.31 |
|
wtWebGraphAnalog57762AlarmFtpOption
mandatory
Binary coded options, select only one option at the same time:
STORE = replace file APPEND = append message at the end of the file Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : STOR… |
OctetStringr/w Constraints: range: 4-4 |
.1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.32 |
|
wtWebGraphAnalog57762AlarmTimerCron
mandatory
This entry defines a time window for alarm 1-8 and a activation time for the report.
A time window is definied by start and stop time stamp, seperated by a space or tab. The activation time of the report is defined by a… |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.33 |
|
wtWebGraphAnalog57762AlarmName
mandatory
Alert name
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.39 |
|
wtWebGraphAnalog57762AlarmActive
mandatory
Alert active
1 = ON 0 = OFF |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.40 |
|
wtWebGraphAnalog57762AlarmHttpReqAuthEnable
mandatory
Binary coded options, select only one option at the same time:
OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 1-7: unused Bit 0 : HHTP Request Authentication enable |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.61 |
|
wtWebGraphAnalog57762AlarmHttpReqAuthUser
mandatory
HTTP Request: User
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.62 |
|
wtWebGraphAnalog57762AlarmHttpReqAuthPassword
mandatory
HTTP Request: Password
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.63 |
|
wtWebGraphAnalog57762AlarmHttpReqSetUrl
mandatory
HTTP Request: Set URL
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.64 |
|
wtWebGraphAnalog57762AlarmHttpReqClearUrl
mandatory
HTTP Request: Clear URL
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.65 |
|
wtWebGraphAnalog57762AlarmHttpReqServerPort
mandatory
HTTP Request: Server Port
|
Integer32r/w Constraints: range: 1-65535 |
.1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.66 |
|
wtWebGraphAnalog57762AlarmMqttTopicPath
mandatory
MQTT Publish: Topic path
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.67 |
|
wtWebGraphAnalog57762AlarmMqttTopicSetTopic
mandatory
MQTT Publish: Topic SET message
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.68 |
|
wtWebGraphAnalog57762AlarmMqttTopicClear
mandatory
MQTT Publish: Topic CLEAR message
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.69 |
|
wtWebGraphAnalog57762AlarmSensorLostSelection
mandatory
Binary coded options:
OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 1-7: unused Bit 0 : Sensor 0 |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.70 |
|
wtWebGraphAnalog57762AlarmLimitWindow
mandatory
If window type is INSIDE the alarm is genereted when the temperature
is greater minumum value and lower than maximum value. If window type is OUTSIDE the alarm is generated when the measured value is lower than the mini… |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.71 |
|
wtWebGraphAnalog57762AlarmSnmpManagerPort
mandatory
Port number of the SNMP Manager to which the Webio device should send SNMP traps.
|
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.76 |
|
wtWebGraphAnalog57762AlarmMqttQoS
mandatory
Binary coded value:
Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: QoS 0 Bit 1: QoS 1 Bit 2: QoS 2 Bit 3-7:unused |
OctetStringr/w Constraints: range: 4-4 |
.1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.77 |
|
wtWebGraphAnalog57762AlarmMqttRetain
mandatory
Binary coded value:
Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : retain enable Bit 1-7 : unused |
OctetStringr/w Constraints: range: 4-4 |
.1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.78 |
.1.3.6.1.4.1.5040.1.2.29.3.1.6.2.3
·
1 row entry
·
2 columns
List of sensor colors for the praphical presentation.
Numbers of the sensors.
Indexes
wtWebGraphAnalog57762SensorNo
| Column | Syntax | OID |
|---|---|---|
|
wtWebGraphAnalog57762GraphicsSensorColor
mandatory
Color of the sensors at the praphical presention.
|
OctetStringr/w Constraints: range: 3-3 |
.1.3.6.1.4.1.5040.1.2.29.3.1.6.2.3.1.1 |
|
wtWebGraphAnalog57762GraphicsSelectScale
mandatory
Assignes one of 4 scales to a sensor:
Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Use Scale 1 Bit 1 : Use Scale 2 Bit 2-7: unused |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.6.2.3.1.2 |
.1.3.6.1.4.1.5040.1.2.29.3.2.1
·
1 row entry
·
14 columns
List of settings depending on the sensor number.
Sensor parameters for the individual sensors.
Indexes
wtWebGraphAnalog57762SensorNo
| Column | Syntax | OID |
|---|---|---|
|
wtWebGraphAnalog57762PortName
mandatory
Name of the sensor.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.2.1.1.1 |
|
wtWebGraphAnalog57762PortText
mandatory
Description of the sensor.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.2.1.1.2 |
|
wtWebGraphAnalog57762PortOffset1
mandatory
Offset calibration: Offset in degrees with maximum 3 decimal places at set point 1.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.2.1.1.3 |
|
wtWebGraphAnalog57762SetPoint1
mandatory
Offset calibration: Reference set point 1 in degrees with maximum 3 decimal places.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.2.1.1.4 |
|
wtWebGraphAnalog57762PortOffset2
mandatory
Offset calibration: Offset in degrees with maximum 3 decimal places at set point 2.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.2.1.1.5 |
|
wtWebGraphAnalog57762SetPoint2
mandatory
Offset calibration: Reference set point 2 in degrees with maximum 3 decimal places.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.2.1.1.6 |
|
wtWebGraphAnalog57762PortComment
mandatory
Offset calibration: informations of date, name of operator, reference devices.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.2.1.1.7 |
|
wtWebGraphAnalog57762PortSensorSelect
mandatory
Binary coded options for sensor 1:
Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : 0-20mA (default) Bit 1 : 4-20mA Bit 2 : Disconnect Bit 3-7: unused |
OctetStringr/w Constraints: range: 4-4 |
.1.3.6.1.4.1.5040.1.2.29.3.2.1.1.8 |
|
wtWebGraphAnalog57762PortUnit
mandatory
User scale: displayed unit.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.2.1.1.9 |
|
wtWebGraphAnalog57762PortScale0
mandatory
User scale: displayed value in 1/1000 at 0% full scale range.
Range: -999999.999 to 999999.999 |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.2.1.1.10 |
|
wtWebGraphAnalog57762PortScale100
mandatory
User scale: displayed value in 1/1000 at 100% full scale range.
Range: -999999.999 to 999999.999 |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.2.1.1.11 |
|
wtWebGraphAnalog57762PortOutputMode
mandatory
This binary coded output mode defines the individual operation mode for any
output. More than one mode must not be selected. If an output mode is selected, Bit 2 in wtWebGraphAnalog57762PortInputMode will be set automat… |
OctetStringr/w Constraints: range: 4-4 |
.1.3.6.1.4.1.5040.1.2.29.3.2.1.1.12 |
|
wtWebGraphAnalog57762PortInputMode
mandatory
This binary coded input mode defines the individual operation mode for any
input. More than one mode must not be selected. If an input mode is selected, Bit 5 in wtWebGraphAnalog57762PortOutputMode will be set automatic… |
OctetStringr/w Constraints: range: 4-4 |
.1.3.6.1.4.1.5040.1.2.29.3.2.1.1.13 |
|
wtWebGraphAnalog57762PortPresetValue
mandatory
This value will be set after reset or initialisation.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.2.1.1.16 |