wtWebGraphAnalog57762AlarmMqttTopicSetTopic
WebGraph-AnalogIO-57762-US-MIB ·
.1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.68
Object
column
mandatory
r/w
OctetString
MQTT Publish: Topic SET message
Context
- MIB
- WebGraph-AnalogIO-57762-US-MIB
- OID
.1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.68- Type
- column
- Access
- readwrite
- Status
- mandatory
- Parent
- wtWebGraphAnalog57762AlarmEntry
- Table
- wtWebGraphAnalog57762AlarmTable
- Siblings
- 48
Syntax
OctetString
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| wtWebGraphAnalog57762AlarmTrigger mandatory Binary coded trigger conditions:
Octet 1: unused
Octet 2: unused
Octet 3:
Bit 0: Timer
Bit 1: ColdStart
Bit 2: WarmStart
Octet 4:
Bit 0: Sensor 1
Bit 1: Senso… | column | OctetString | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.1 |
| wtWebGraphAnalog57762AlarmMailText mandatory Alarm mail text: <Mn> provides the current temperature; n = 1..2.
<Z> provides the current time. | column | OctetString | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.10 |
| wtWebGraphAnalog57762AlarmManagerIP mandatory Name or IP address of the SNMP Manager which accepts the trap. | column | OctetString | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.11 |
| wtWebGraphAnalog57762AlarmTrapText mandatory This text is sent in the trap body. | column | OctetString | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.12 |
| wtWebGraphAnalog57762AlarmMailOptions mandatory Binary coded options:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : Attach Thermo.csv Enable
Bit 1 : CSV-Data_since_last_report
Bit 2-7: unused | column | OctetString | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.13 |
| wtWebGraphAnalog57762AlarmTcpIpAddr mandatory Name or IP address of the TCP server which accepts the trap. | column | OctetString | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.14 |
| wtWebGraphAnalog57762AlarmTcpPort mandatory Port number of the TCP server which accepts the trap. | column | Integer32 | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.15 |
| wtWebGraphAnalog57762AlarmTcpText mandatory This text is sent in the TCP trap body. | column | OctetString | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.16 |
| wtWebGraphAnalog57762AlarmClearMailSubject mandatory Subject line for alarm clear mail. | column | OctetString | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.17 |
| wtWebGraphAnalog57762AlarmClearMailText mandatory Alarm clear mail text: <Mn> provides the current temperature; n = 1..2.
<Z> provides the current time. | column | OctetString | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.18 |
| wtWebGraphAnalog57762AlarmClearTrapText mandatory This text is sent in the trap body. | column | OctetString | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.19 |
| wtWebGraphAnalog57762AlarmMin1 mandatory Minimum sensor 1 with maximum 3 decimal places. | column | OctetString | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.2 |
| wtWebGraphAnalog57762AlarmClearTcpText mandatory This text is sent in the TCP trap body. | column | OctetString | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.20 |
| wtWebGraphAnalog57762AlarmMin2 mandatory Minimum sensor 2 with maximum 3 decimal places. | column | OctetString | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.21 |
| wtWebGraphAnalog57762AlarmMax2 mandatory Maximum sensor 2 with maximum 2 decimal places. | column | OctetString | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.22 |
| wtWebGraphAnalog57762AlarmHysteresis2 mandatory Hysterese rel. sensor 2 with maximum 3 decimal places. | column | OctetString | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.23 |
| wtWebGraphAnalog57762AlarmSyslogIpAddr mandatory IP address of the syslog server to which the Webio device should send syslog messages. | column | OctetString | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.24 |
| wtWebGraphAnalog57762AlarmSyslogPort mandatory Port number of the syslog server to which the Webio device should send syslog messages. | column | Integer32 | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.25 |
| wtWebGraphAnalog57762AlarmSyslogText mandatory Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
This text appears in the following syslog message body. | column | OctetString | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.26 |
| wtWebGraphAnalog57762AlarmSyslogClearText mandatory Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
This text appears in the following syslog message body of a alarm clear messag… | column | OctetString | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.27 |
| wtWebGraphAnalog57762AlarmFtpDataPort mandatory Local data port: 1..65535 or AUTO: the next free port will be assigned. | column | OctetString | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.28 |
| wtWebGraphAnalog57762AlarmFtpFileName mandatory Name of the file including path informations. | column | OctetString | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.29 |
| wtWebGraphAnalog57762AlarmMax1 mandatory Maximum sensor 1 with maximum 3 decimal places. | column | OctetString | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.3 |
| wtWebGraphAnalog57762AlarmFtpText mandatory Message text to store on the FTP server. | column | OctetString | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.30 |
| wtWebGraphAnalog57762AlarmFtpClearText mandatory Alarm clear message to store on the FTP server. | column | OctetString | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.31 |
| wtWebGraphAnalog57762AlarmFtpOption mandatory Binary coded options, select only one option at the same time:
STORE = replace file
APPEND = append message at the end of the file
Octet 1: unused
Octet 2: unused
… | column | OctetString | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.32 |
| wtWebGraphAnalog57762AlarmTimerCron mandatory This entry defines a time window for alarm 1-8 and a activation time for the report.
A time window is definied by start and stop time stamp, seperated by a space or tab.
The activ… | column | OctetString | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.33 |
| wtWebGraphAnalog57762AlarmName mandatory Alert name | column | OctetString | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.39 |
| wtWebGraphAnalog57762AlarmHysteresis1 mandatory Reading changes of this size clears the alarm state (MAX-hyst, MIN+hyst.)
with maximum 3 decimal places. | column | OctetString | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.4 |
| wtWebGraphAnalog57762AlarmActive mandatory Alert active
1 = ON
0 = OFF | column | OctetString | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.40 |
| wtWebGraphAnalog57762AlarmDelay mandatory Alarm will be delayed by setting this time while stable alarm
condition occur (time in minutes). | column | OctetString | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.5 |
| wtWebGraphAnalog57762AlarmInterval mandatory Send interval for alarm messages. | column | OctetString | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.6 |
| wtWebGraphAnalog57762AlarmHttpReqAuthEnable mandatory Binary coded options, select only one option at the same time:
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4, Bit 1-7: unused
Bit 0 : HHTP Request Authentication enable | column | OctetString | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.61 |
| wtWebGraphAnalog57762AlarmHttpReqAuthUser mandatory HTTP Request: User | column | OctetString | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.62 |
| wtWebGraphAnalog57762AlarmHttpReqAuthPassword mandatory HTTP Request: Password | column | OctetString | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.63 |
| wtWebGraphAnalog57762AlarmHttpReqSetUrl mandatory HTTP Request: Set URL | column | OctetString | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.64 |
| wtWebGraphAnalog57762AlarmHttpReqClearUrl mandatory HTTP Request: Clear URL | column | OctetString | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.65 |
| wtWebGraphAnalog57762AlarmHttpReqServerPort mandatory HTTP Request: Server Port | column | Integer32 | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.66 |
| wtWebGraphAnalog57762AlarmMqttTopicPath mandatory MQTT Publish: Topic path | column | OctetString | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.67 |
| wtWebGraphAnalog57762AlarmMqttTopicClear mandatory MQTT Publish: Topic CLEAR message | column | OctetString | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.69 |
| wtWebGraphAnalog57762AlarmEnable mandatory Binary coded alarm enable:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0: Mail Enable
Bit 1: SNMP Trap enable
Bit 2: TCP Client enable | column | OctetString | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.7 |
| wtWebGraphAnalog57762AlarmSensorLostSelection mandatory Binary coded options:
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4, Bit 1-7: unused
Bit 0 : Sensor 0 | column | OctetString | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.70 |
| wtWebGraphAnalog57762AlarmLimitWindow mandatory If window type is INSIDE the alarm is genereted when the temperature
is greater minumum value and lower than maximum value. If window type is OUTSIDE
the alarm is generated when t… | column | OctetString | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.71 |
| wtWebGraphAnalog57762AlarmSnmpManagerPort mandatory Port number of the SNMP Manager to which the Webio device should send SNMP traps. | column | Integer32 | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.76 |
| wtWebGraphAnalog57762AlarmMqttQoS mandatory Binary coded value:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0: QoS 0
Bit 1: QoS 1
Bit 2: QoS 2
Bit 3-7:unused | column | OctetString | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.77 |
| wtWebGraphAnalog57762AlarmMqttRetain mandatory Binary coded value:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : retain enable
Bit 1-7 : unused | column | OctetString | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.78 |
| wtWebGraphAnalog57762AlarmEMailAddr mandatory E-Mail address for sending the alarm mail to. | column | OctetString | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.8 |
| wtWebGraphAnalog57762AlarmMailSubject mandatory Subject line for alarm mail. | column | OctetString | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.9 |