wtWebGraphAnalog57762BinaryTcpServerHysteresis1
WebGraph-AnalogIO-57762-US-MIB ·
.1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.23
Object
column
mandatory
r/w
OctetString
A change greater than this value initiate a transmission of the corresponding input value. The input 1 must be selected at wtWebGraphAnalog57762BinaryTcpServerInputTrigger. With a hysteresis of zero any change will be transmitted.
Context
- MIB
- WebGraph-AnalogIO-57762-US-MIB
- OID
.1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.23- Type
- column
- Access
- readwrite
- Status
- mandatory
- Parent
- wtWebGraphAnalog57762BinaryEntry
- Table
- wtWebGraphAnalog57762BinaryTable
- Siblings
- 28
Syntax
OctetString
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| wtWebGraphAnalog57762BinaryOperationMode mandatory Selection of the operation mode:
The OCTETS are interpreted bit-by-bit,
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4: Bit 3-7: unused
Bi… | column | OctetString | .1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.1 |
| wtWebGraphAnalog57762BinaryTcpClientInputTrigger mandatory Every change on the inputs causes their state to be transmitted to the
remote device. To minimize data traffic, individual inputs may be exempted
from this rule. Nevertheless ev… | column | OctetString | .1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.10 |
| wtWebGraphAnalog57762BinaryTcpClientInterval mandatory Configurable interval with a 100ms base, in which the Webio device sends
data to the configured application. A interval of zero stopps the
periodical sending. | column | Integer32 | .1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.11 |
| wtWebGraphAnalog57762BinaryTcpClientApplicationMode mandatory Selection of the application mode:
The OCTETS are interpreted bit-by-bit,
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4: Bit 3-7: unused
… | column | OctetString | .1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.12 |
| wtWebGraphAnalog57762BinaryUdpPeerLocalPort mandatory Local UDP port for data exchange in this peer to peer mode.
This port number must be unique within the device.
Reserved port number must not be used (refere to the manual). | column | Integer32 | .1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.13 |
| wtWebGraphAnalog57762BinaryUdpPeerRemotePort mandatory Port number of the remote device. A complete set of port number, IP address
and a valid input/output mask starts this mode.
No data exchange take place when setting the remote por… | column | Integer32 | .1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.14 |
| wtWebGraphAnalog57762BinaryUdpPeerRemoteIpAddr mandatory Ip address of the remote device. A complete set of port number, IP address
and a valid input/output mask starts this mode.
No data exchange take place when setting the remote devi… | column | OctetString | .1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.15 |
| wtWebGraphAnalog57762BinaryUdpPeerInputTrigger mandatory Every change on the inputs causes their state to be transmitted to the
remote device. To minimize data traffic, individual inputs may be exempted
from this rule. Nevertheless ev… | column | OctetString | .1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.16 |
| wtWebGraphAnalog57762BinaryUdpPeerInterval mandatory Configurable interval with a 100ms base, in which the Webio device sends
data to the configured remote device. A interval of zero stopps the
periodical sending. | column | Integer32 | .1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.17 |
| wtWebGraphAnalog57762BinaryUdpPeerApplicationMode mandatory Selection of the application mode:
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
… | column | OctetString | .1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.18 |
| wtWebGraphAnalog57762BinaryConnectedPort mandatory Port number of the remote device, after connection has been established.
In case of no connection or missing port informations a zero will be read. | column | Integer32 | .1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.19 |
| wtWebGraphAnalog57762BinaryTcpServerLocalPort mandatory Local TCP port for data exchange in this server mode.
This port number must be unique within the device.
Reserved port number must not be used (refere to the manual). | column | Integer32 | .1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.2 |
| wtWebGraphAnalog57762BinaryConnectedIpAddr mandatory IP address of the remote device, after connection has been established.
In case of no connection or missing port informations 0.0.0.0 will be read. | column | RFC1155-SMIIpAddress | .1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.20 |
| wtWebGraphAnalog57762BinaryTcpServerClientHttpPort mandatory HTTP port number of the remote device at TCP Server Mode. If an mailfunction occurs
status informations will be send to this port.
Not used at mode Compatible 50xxx. | column | Integer32 | .1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.21 |
| wtWebGraphAnalog57762BinaryTcpClientServerHttpPort mandatory HTTP port number of the remote device at TCP Client Mode. In the operating mode
Box2Box connection status informations will be exchanged through this port. | column | Integer32 | .1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.22 |
| wtWebGraphAnalog57762BinaryTcpServerHysteresis2 mandatory A change greater than this value initiate a transmission of the corresponding input value.
The input 2 must be selected at wtWebGraphAnalog57762BinaryTcpServerInputTrigger.
With a… | column | OctetString | .1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.24 |
| wtWebGraphAnalog57762BinaryTcpClientHysteresis1 mandatory A change greater than this value initiate a transmission of the corresponding input value.
The input 1 must be selected at wtWebGraphAnalog57762BinaryTcpClientInputTrigger.
With a… | column | OctetString | .1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.25 |
| wtWebGraphAnalog57762BinaryTcpClientHysteresis2 mandatory A change greater than this value initiate a transmission of the corresponding input value.
The input 2 must be selected at wtWebGraphAnalog57762BinaryTcpClientInputTrigger.
With a… | column | OctetString | .1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.26 |
| wtWebGraphAnalog57762BinaryUdpPeerHysteresis1 mandatory A change greater than this value initiate a transmission of the corresponding input value.
The input 1 must be selected at wtWebGraphAnalog57762BinaryUdpPeerInputTrigger.
With a h… | column | OctetString | .1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.27 |
| wtWebGraphAnalog57762BinaryUdpPeerHysteresis2 mandatory A change greater than this value initiate a transmission of the corresponding input value.
The input 2 must be selected at wtWebGraphAnalog57762BinaryUdpPeerInputTrigger.
With a h… | column | OctetString | .1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.28 |
| wtWebGraphAnalog57762BinaryTcpClientServerUserName mandatory Building a connection may be protected by a specific
user name within the server. Enter the user name
to establish the connection, if a user name entry
exists. | column | OctetString | .1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.29 |
| wtWebGraphAnalog57762BinaryTcpServerInputTrigger mandatory Every change on the inputs causes their state to be transmitted to the
remote device. To minimize data traffic, individual inputs may be exempted
from this rule. Nevertheless ev… | column | OctetString | .1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.3 |
| wtWebGraphAnalog57762BinaryTcpServerApplicationMode mandatory Selection of the application mode:
The OCTETS are interpreted bit-by-bit,
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4: Bit 4-7: unused
… | column | OctetString | .1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.4 |
| wtWebGraphAnalog57762BinaryTcpClientLocalPort mandatory Local TCP port for data exchange in this client mode.
This port number must be unique within the device.
Reserved port number must not be used (refere to the manual). | column | Integer32 | .1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.5 |
| wtWebGraphAnalog57762BinaryTcpClientServerPort mandatory Port number of the server. A complete set of port number, IP address
and a valid input/output mask starts this mode.
No data exchange take place when setting the server port to ze… | column | Integer32 | .1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.6 |
| wtWebGraphAnalog57762BinaryTcpClientServerIpAddr mandatory Ip address of the server. A complete set of port number, IP address
and a valid input/output mask starts this mode.
No data exchange take place when setting the server IP address … | column | OctetString | .1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.7 |
| wtWebGraphAnalog57762BinaryTcpClientServerPassword mandatory Building a connection may be protected by the
administrator password of the server. Enter the server password
to establish the connection, if a server administrator password
exis… | column | OctetString | .1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.8 |
| wtWebGraphAnalog57762BinaryTcpClientInactivity mandatory Connection timeout in 100ms. If no data are exchanged within the specified
time, the device closes the connection to the server.
The value 0 deactivates the timer. Using the Box… | column | Integer32 | .1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.9 |