SCHLEIFENBAUER-DATABUS-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
16
Rows
16
Columns
138
sdbMgmtCtrlDevicesTable
table.1.3.6.1.4.1.31034.12.1.1.1.2.4
·
1 row entry
·
5 columns
A table containing information of devices connected to the databus. The number of entries is given by the value of sdbMgmtStsDevices.
Information entry containing objects of a particular databus device.
Indexes
sdbMgmtCtrlDevIndex
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
sdbMgmtCtrlDevIndex
A unique value for each device. Its value ranges between 1 and the
value of sdbMgmtStsDevices with a maximum of 255. The value for each device will remain constant until the next scan is performed. |
Integer32 Constraints: range: 1-255 |
.1.3.6.1.4.1.31034.12.1.1.1.2.4.1.1 |
||||
|
sdbMgmtCtrlDevUnitAddress
User defined address.
This will be used for addressing the device on the databus. |
Integer32r/w Constraints: range: 0-65535 |
.1.3.6.1.4.1.31034.12.1.1.1.2.4.1.2 |
||||
|
sdbMgmtCtrlDevHardwareAddress
Hardware serial number.
This cannot be changed. It can be used as backup unit address. format as 3 unsigned ints separated by dashes: int - int - int |
OctetString Constraints: range: 17-17 |
.1.3.6.1.4.1.31034.12.1.1.1.2.4.1.3 |
||||
|
sdbMgmtCtrlDevIsNew
Indication if the device is new on the databus.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.31034.12.1.1.1.2.4.1.4 |
||||
|
sdbMgmtCtrlDevIsDuplicate
Indication if the device is conflicting with another device on the
databus. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.31034.12.1.1.1.2.4.1.5 |
sdbDevIdTable
table.1.3.6.1.4.1.31034.12.1.1.2.1.1
·
1 row entry
·
16 columns
A table containing identification information of devices connected to the databus. The number of entries is given by the value of sdbMgmtStsAddressableDevices.
Information entry containing information objects of a particular
databus device.
databus device.
Indexes
sdbDevIdIndex
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
sdbDevIdSPDMVersion
Data model version.
|
Integer32 Constraints: range: 0-9999 |
.1.3.6.1.4.1.31034.12.1.1.2.1.1.1.1 |
||||||||
|
sdbDevIdFirmwareVersion
The firmware revision number.
|
Integer32 Constraints: range: 0-9999 |
.1.3.6.1.4.1.31034.12.1.1.2.1.1.1.2 |
||||||||
|
sdbDevIdBuildNumber
Date and time the firmware was built.
|
OctetString Constraints: range: 0-12 |
.1.3.6.1.4.1.31034.12.1.1.2.1.1.1.3 |
||||||||
|
sdbDevIdSalesOrderNumber
SP sales order number.
|
OctetString Constraints: range: 0-16 |
.1.3.6.1.4.1.31034.12.1.1.2.1.1.1.4 |
||||||||
|
sdbDevIdProductId
SP product id.
|
OctetString Constraints: range: 0-16 |
.1.3.6.1.4.1.31034.12.1.1.2.1.1.1.5 |
||||||||
|
sdbDevIdSerialNumber
SP serial number.
|
OctetString Constraints: range: 0-16 |
.1.3.6.1.4.1.31034.12.1.1.2.1.1.1.6 |
||||||||
|
sdbDevIdHardwareAddress
Hardware serial number.
This can not be changed. It can be used as backup unit address. Format as 3 unsigned ints separated by dashes (-) e.g. 12345-54321-00000 |
OctetString Constraints: range: 17-17 |
.1.3.6.1.4.1.31034.12.1.1.2.1.1.1.7 |
||||||||
|
sdbDevIdMacAddress
The MAC address.
This can not be changed. It represents an 802 MAC address as if it were transmitted least significant bit first. Format as six groups of 2 hexadecimal digits separated by colons (:) e.g. D0:22:12:B0:00:… |
OctetString Constraints: range: 17-17 |
.1.3.6.1.4.1.31034.12.1.1.2.1.1.1.8 |
||||||||
|
sdbDevIdUnitAddress
User defined address.
This will be used for addressing the device on the databus. |
Integer32r/w Constraints: range: 0-65535 |
.1.3.6.1.4.1.31034.12.1.1.2.1.1.1.9 |
||||||||
|
sdbDevIdName
User configurable device name or identifier.
|
OctetStringr/w Constraints: range: 0-16 |
.1.3.6.1.4.1.31034.12.1.1.2.1.1.1.10 |
||||||||
|
sdbDevIdLocation
User configurable device location identifier.
|
OctetStringr/w Constraints: range: 0-16 |
.1.3.6.1.4.1.31034.12.1.1.2.1.1.1.11 |
||||||||
|
sdbDevIdVanityTag
Characters to be displayed as vanity text in display.
|
OctetStringr/w Constraints: range: 0-20 |
.1.3.6.1.4.1.31034.12.1.1.2.1.1.1.12 |
||||||||
|
sdbDevIdIndex
A unique value for each device. Its value represents the unit address
of the device and is used to address individual devices in the tree. The value for each device will remain constant until the next scan is performed. |
Integer32 Constraints: range: 1-65535 |
.1.3.6.1.4.1.31034.12.1.1.2.1.1.1.13 |
||||||||
|
sdbDevIdDeviceType
A unique value for each device group.
Its value represents the device type of the device. Refer to manual for more information. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.31034.12.1.1.2.1.1.1.14 |
||||||||
|
sdbDevIdLocateUnit
The LCD-backlight flashes in a heartbeat rhythm to locate the unit.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.31034.12.1.1.2.1.1.1.15 |
||||||||
|
sdbDevIdConfigType
Wiring configuration type used.
|
Integer32 Constraints: range: 0-256 |
.1.3.6.1.4.1.31034.12.1.1.2.1.1.1.16 |
sdbDevCfTable
table.1.3.6.1.4.1.31034.12.1.1.2.2.1
·
1 row entry
·
10 columns
A table containing configuration information of devices connected to the databus. The number of entries is given by the value of sdbMgmtStsAddressableDevices.
Configuration entry containing configuration objects of a particular
databus device.
databus device.
Indexes
sdbDevIdIndex
| Column | Syntax | OID |
|---|---|---|
|
sdbDevCfPhases
Number of phases for input metering.
|
Integer32 Constraints: range: 3-3range: 0-1 |
.1.3.6.1.4.1.31034.12.1.1.2.2.1.1.1 |
|
sdbDevCfOutletsTotal
Total number of outlets including hardwired without switch/metered
modules. |
Integer32 Constraints: range: 0-54 |
.1.3.6.1.4.1.31034.12.1.1.2.2.1.1.2 |
|
sdbDevCfOutletsSwitched
Number of switched outlets.
If outlet numbering is non-contiguous its the highest outlet number. |
Integer32 Constraints: range: 0-54 |
.1.3.6.1.4.1.31034.12.1.1.2.2.1.1.3 |
|
sdbDevCfOutletsMetered
Number of metered outlets.
If outlet numbering is non-contiguous its the highest outlet number. |
Integer32 Constraints: range: 0-54 |
.1.3.6.1.4.1.31034.12.1.1.2.2.1.1.4 |
|
sdbDevCfSensors
The number sensors.
|
Integer32 Constraints: range: 0-16 |
.1.3.6.1.4.1.31034.12.1.1.2.2.1.1.5 |
|
sdbDevCfMaximumLoad
Maximum rated load of device per phase
|
AInteger32 Constraints: range: 32-32range: 16-16 |
.1.3.6.1.4.1.31034.12.1.1.2.2.1.1.6 |
|
sdbDevCfBranches
Number of branches for input metering.
|
Integer32 Constraints: range: 0-6 |
.1.3.6.1.4.1.31034.12.1.1.2.2.1.1.7 |
|
sdbDevCfNeutral
Nuetral current measurement.
|
Integer32 Constraints: range: 0-1 |
.1.3.6.1.4.1.31034.12.1.1.2.2.1.1.8 |
|
sdbDevCfTempSensors
Number of temperature sensors present in the system.
|
Integer32 Constraints: range: 0-16 |
.1.3.6.1.4.1.31034.12.1.1.2.2.1.1.9 |
|
sdbDevCfTotals
The number of totals rows for the configuration.
|
Integer32 Constraints: range: 0-16 |
.1.3.6.1.4.1.31034.12.1.1.2.2.1.1.10 |
sdbDevSsTable
table.1.3.6.1.4.1.31034.12.1.1.2.3.1
·
1 row entry
·
14 columns
A table containing system status information of devices connected to the databus. The number of entries is given by the value of sdbMgmtStsAddressableDevices.
System status entry containing system status objects of a particular
databus device.
databus device.
Indexes
sdbDevIdIndex
| Column | Syntax | OID |
|---|---|---|
|
sdbDevSsDeviceStatusCode
Returns an internal status or error code.
A value of 0 means OK. If not 0 it can be any of the following codes. Multiple status codes can be active at the same time. The value will be the sum of the active status codes.… |
Integer32 Constraints: range: 0-255 |
.1.3.6.1.4.1.31034.12.1.1.2.3.1.1.1 |
|
sdbDevSsTemperatureAlert
An alert has been raised due to temperature exceeding treshhold.
0 = no alert 1 = internal temperature sensor 2 = external temperature sensor |
Integer32 Constraints: range: 0-2 |
.1.3.6.1.4.1.31034.12.1.1.2.3.1.1.2 |
|
sdbDevSsInputCurrentAlert
An alert has been raised due to current exceeding treshhold.
The value indicates the exceeding phase. 0 = no alert. |
Integer32 Constraints: range: 0-3 |
.1.3.6.1.4.1.31034.12.1.1.2.3.1.1.3 |
|
sdbDevSsOutletCurrentAlert
An alert has been raised due to current exceeding treshhold.
The value indicates the exceeding outlet. 0 = no alert. |
Integer32 Constraints: range: 0-54 |
.1.3.6.1.4.1.31034.12.1.1.2.3.1.1.4 |
|
sdbDevSsInputVoltageAlert
An alert has been raised due to a voltage dip.
The value indicates the dipped phase. 0 = no alert. |
Integer32 Constraints: range: 0-3 |
.1.3.6.1.4.1.31034.12.1.1.2.3.1.1.5 |
|
sdbDevSsOutletCurrentDropAlert
An alert has been raised due to the current of a metered outlet
suddenly dropping to near zero, possibly indicating a blown fuse. The value indicates the dropped outlet. 0 = no alert. |
Integer32 Constraints: range: 0-54 |
.1.3.6.1.4.1.31034.12.1.1.2.3.1.1.6 |
|
sdbDevSsInputCurrentDropAlert
An alert has been raised due to the current of a metered input
suddenly dropping to near zero, possibly indicating a blown fuse. The value indicates the dropped phase. 0 = no alert. |
Integer32 Constraints: range: 0-3 |
.1.3.6.1.4.1.31034.12.1.1.2.3.1.1.7 |
|
sdbDevSsSensorChangeAlert
An alert has been raised due to a change in the number of sensors.
The value indicates the previous amount of sensors. |
Integer32 Constraints: range: 0-16 |
.1.3.6.1.4.1.31034.12.1.1.2.3.1.1.8 |
|
sdbDevSsOutletVoltageDropAlert
An alert has been raised due to voltage drop on this outlet.
The value indicates the first failed outlet. |
Integer32 Constraints: range: 0-54 |
.1.3.6.1.4.1.31034.12.1.1.2.3.1.1.9 |
|
sdbDevSsBranchCurrentAlert
An alert has been raised due to current exceeding treshhold.
The value indicates the exceeding branch. 0 = no alert. |
Integer32 Constraints: range: 0-18 |
.1.3.6.1.4.1.31034.12.1.1.2.3.1.1.10 |
|
sdbDevSsBranchVoltageAlert
An alert has been raised due to a voltage dip.
The value indicates the dipped branch. 0 = no alert. |
Integer32 Constraints: range: 0-18 |
.1.3.6.1.4.1.31034.12.1.1.2.3.1.1.11 |
|
sdbDevSsNeutralCurrentAlert
An alert has been raised due to current exceeding treshhold.
0 = no alert 1 = current alert |
Integer32 Constraints: range: 0-1 |
.1.3.6.1.4.1.31034.12.1.1.2.3.1.1.12 |
|
sdbDevSsResidualCurrentAlert
A residual current alert has been raised.
0 = no alert 1 = current exceeding treshhold alert 2 = sensor error |
Integer32 Constraints: range: 0-2 |
.1.3.6.1.4.1.31034.12.1.1.2.3.1.1.13 |
|
sdbDevSsHardwareAlert
0 = no alarm >0 = or slave number for alert
|
Integer32 Constraints: range: 0-9 |
.1.3.6.1.4.1.31034.12.1.1.2.3.1.1.14 |
sdbDevRsTable
table.1.3.6.1.4.1.31034.12.1.1.2.4.1
·
1 row entry
·
5 columns
A table providing reset capabilities to devices connected to the databus. The number of entries is given by the value of sdbMgmtStsAddressableDevices.
Reset entry providing reset objects of a particular databus device.
Indexes
sdbDevIdIndex
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
sdbDevRsReboot
Warm reboot/reset of device controller.
NOTE: this will have NO effect on outlet status! |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.31034.12.1.1.2.4.1.1.1 |
||||
|
sdbDevRsResetAlerts
Reset all alert signals and device status code.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.31034.12.1.1.2.4.1.1.2 |
||||
|
sdbDevRsZeroInputKWhSubtotal
Reset of all input kWh subtotal counters to zero.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.31034.12.1.1.2.4.1.1.3 |
||||
|
sdbDevRsZeroOutletKWhSubtotal
Reset of all outlet kWh subtotal counter to zero.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.31034.12.1.1.2.4.1.1.4 |
||||
|
sdbDevRsResetPeaksAndDips
Reset all peak and dip values to zero.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.31034.12.1.1.2.4.1.1.5 |
sdbDevStTable
table.1.3.6.1.4.1.31034.12.1.1.2.5.1
·
1 row entry
·
13 columns
A table containing setting information of devices connected to the databus. The number of entries is given by the value of sdbMgmtStsAddressableDevices.
Setting entry containing settings objects of a particular databus
device.
device.
Indexes
sdbDevIdIndex
| Column | Syntax | OID | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
sdbDevStAutoResetAlerts
Auto reset alerts configuration.
If set to 0 the auto reset alerts feature is disabled. If set to a value greater then 0, the auto reset alerts feature is enabled and alerts will get cleared after the configured amount … |
secondsInteger32r/w Constraints: range: 0-65535 |
.1.3.6.1.4.1.31034.12.1.1.2.5.1.1.2 |
||||||||||
|
sdbDevStExtendedNames
Use original or longer names for inputs, outlets and sensors.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.31034.12.1.1.2.5.1.1.3 |
||||||||||
|
sdbDevStPeakDuration
Amount of ms a current peak should last before an alert is raised.
|
msInteger32r/w Constraints: range: 0-65535 |
.1.3.6.1.4.1.31034.12.1.1.2.5.1.1.4 |
||||||||||
|
sdbDevStFixedOutletDelay
Minimal delay between two successive relay switches in milliseconds.
Minimal delay is 100 ms. Will always be respected! |
msInteger32r/w Constraints: range: 100-65535 |
.1.3.6.1.4.1.31034.12.1.1.2.5.1.1.5 |
||||||||||
|
sdbDevStPowerSaverMode
Set backlight on time in seconds.
0 keeps display always on. Note that keeping the backlight on may decrease luminosity over time. |
sInteger32r/w Constraints: range: 120-120range: 240-240range: 60-60range: 10-10range: 0-0 |
.1.3.6.1.4.1.31034.12.1.1.2.5.1.1.6 |
||||||||||
|
sdbDevStOutletPowerUpMode
Behaviour of outlets on power-up.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.31034.12.1.1.2.5.1.1.7 |
||||||||||
|
sdbDevStMaximumTemperature
Maximum temperature threshold
An alert will be generated whenever the temperature is above this value. Zero means disabled. |
degrees CelsiusInteger32r/w Constraints: range: 0-99 |
.1.3.6.1.4.1.31034.12.1.1.2.5.1.1.8 |
||||||||||
|
sdbDevStDisplayOrientation
Display orientation.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.31034.12.1.1.2.5.1.1.9 |
||||||||||
|
sdbDevStLocalAlertReset
Allow alerts to be reset locally on device by pushing one of the
buttons. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.31034.12.1.1.2.5.1.1.10 |
||||||||||
|
sdbDevStCurrentDropDetection
Enables the current drop detection function.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.31034.12.1.1.2.5.1.1.11 |
||||||||||
|
sdbDevStUsbMode
Allow the USB port to be used for specific tasks
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.31034.12.1.1.2.5.1.1.13 |
||||||||||
|
sdbDevStSensorChangeAlertMode
Enable sensoe change alerts
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.31034.12.1.1.2.5.1.1.14 |
||||||||||
|
sdbDevStOutletUnlockOverride
Overrides the timeout. If this is set to 1 then the timeout will be ignored, otherwise the timeout will be taken into account.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.31034.12.1.1.2.5.1.1.15 |
sdbDevInTable
table.1.3.6.1.4.1.31034.12.1.1.2.6.1
·
1 row entry
·
14 columns
A table containing information of inputs of devices connected to the databus.
Inputs entry containing objects of an input of a particular databus
device.
Note that this table has two indexes. sdbDevIdIndex to identify a
particular device and sdbDevInIndex to identify a particular input
of the dev…
device.
Note that this table has two indexes. sdbDevIdIndex to identify a
particular device and sdbDevInIndex to identify a particular input
of the dev…
Indexes
sdbDevIdIndex sdbDevInIndex
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
sdbDevInIndex
A unique value for each input. Its value ranges between 1 and the
value of sdbDevCfPhases. |
Integer32 Constraints: range: 1-54 |
.1.3.6.1.4.1.31034.12.1.1.2.6.1.1.1 |
||||
|
sdbDevInKWhTotal
Total kWh value of an input. This value can not be reset.
|
kWhKiloWattHour Textual Convention: KiloWattHour Integer32Type Constraints: range: 0..16777215 |
.1.3.6.1.4.1.31034.12.1.1.2.6.1.1.2 |
||||
|
sdbDevInKWhSubtotal
Subtotal kWh value of an input. This value can be reset.
|
kWhKiloWattHour Textual Convention: KiloWattHour Integer32Type Constraints: range: 0..16777215 |
.1.3.6.1.4.1.31034.12.1.1.2.6.1.1.3 |
||||
|
sdbDevInPowerFactor
Power factor of input.
The power factor of an AC power system is defined as the ratio of the real or active power to the apparent power and is a number between 0 and 1. This value is expressed as a percentage between 0%… |
%CentiPercent Textual Convention: CentiPercent Integer32Type Constraints: range: 0..10000 |
.1.3.6.1.4.1.31034.12.1.1.2.6.1.1.4 |
||||
|
sdbDevInActualCurrent
Actual apparent, RMS current.
|
ACentiAmpere Textual Convention: CentiAmpere Integer32Type Constraints: range: 0..327680 |
.1.3.6.1.4.1.31034.12.1.1.2.6.1.1.5 |
||||
|
sdbDevInPeakCurrent
Peak apparent, RMS current.
Highest value since last reset of the alerts. |
ACentiAmpere Textual Convention: CentiAmpere Integer32Type Constraints: range: 0..327680 |
.1.3.6.1.4.1.31034.12.1.1.2.6.1.1.6 |
||||
|
sdbDevInActualVoltage
The actual voltage.
|
VCentiVolt Textual Convention: CentiVolt Integer32Type Constraints: range: 0..327680 |
.1.3.6.1.4.1.31034.12.1.1.2.6.1.1.7 |
||||
|
sdbDevInMinVoltage
RMS voltage dip.
Lowest value since reset of alerts. |
VCentiVolt Textual Convention: CentiVolt Integer32Type Constraints: range: 0..327680 |
.1.3.6.1.4.1.31034.12.1.1.2.6.1.1.8 |
||||
|
sdbDevInPowerVoltAmpere
Calculated apparent power.
|
VAInteger32 Constraints: range: 0-327680 |
.1.3.6.1.4.1.31034.12.1.1.2.6.1.1.9 |
||||
|
sdbDevInPowerWatt
Calculated real power.
|
WInteger32 Constraints: range: 0-327680 |
.1.3.6.1.4.1.31034.12.1.1.2.6.1.1.10 |
||||
|
sdbDevInMaxAmps
Maximum current per input phase.
Should last at least sdbDevStPeakDuration ms before triggering an alert. |
ACentiAmperer/w Textual Convention: CentiAmpere Integer32Type Constraints: range: 0..327680 |
.1.3.6.1.4.1.31034.12.1.1.2.6.1.1.11 |
||||
|
sdbDevInCTRatio
The multiplier to use for the input CTs.
|
Integer32r/w Constraints: range: 0-255 |
.1.3.6.1.4.1.31034.12.1.1.2.6.1.1.12 |
||||
|
sdbDevInName
User configurable naming of inputs or phases.
|
OctetStringr/w Constraints: range: 0-8 |
.1.3.6.1.4.1.31034.12.1.1.2.6.1.1.13 |
||||
|
sdbDevInZeroKWhSubtotal
Reset input kWh subtotal counter of a single input to zero.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.31034.12.1.1.2.6.1.1.14 |
sdbDevOutTable
table.1.3.6.1.4.1.31034.12.1.1.2.7.1
·
1 row entry
·
2 columns
A table containing information of outlets of devices connected to the databus.
Outlets entry containing objects of an outlet of a particular databus
device.
Note that this table has two indexes. sdbDevIdIndex to identify a
particular device and sdbDevOutIndex to identify a particular outlet
of the…
device.
Note that this table has two indexes. sdbDevIdIndex to identify a
particular device and sdbDevOutIndex to identify a particular outlet
of the…
Indexes
sdbDevIdIndex sdbDevOutIndex
| Column | Syntax | OID |
|---|---|---|
|
sdbDevOutIndex
A unique value for each outlet. Its value ranges between 1 and the
value of sdbDevCfOutletsTotal. |
Integer32 Constraints: range: 1-54 |
.1.3.6.1.4.1.31034.12.1.1.2.7.1.1.1 |
|
sdbDevOutName
User configurable naming of individual outlets.
|
OctetStringr/w Constraints: range: 0-8 |
.1.3.6.1.4.1.31034.12.1.1.2.7.1.1.2 |
sdbDevOutMtTable
table.1.3.6.1.4.1.31034.12.1.1.2.7.2
·
1 row entry
·
11 columns
A table containing information of metered outlets of devices connected to the databus.
Metered outlets entry containing objects of a metered outlet of a
particular databus device.
Note that this table has two indexes. sdbDevIdIndex to identify a
particular device and sdbDevOutMtIndex to identify a particu…
particular databus device.
Note that this table has two indexes. sdbDevIdIndex to identify a
particular device and sdbDevOutMtIndex to identify a particu…
Indexes
sdbDevIdIndex sdbDevOutMtIndex
| Column | Syntax | OID |
|---|---|---|
|
sdbDevOutMtIndex
A unique value for each outlet. Its value ranges between 1 and the
value of sdbDevCfOutletsMetered. |
Integer32 Constraints: range: 1-54 |
.1.3.6.1.4.1.31034.12.1.1.2.7.2.1.1 |
|
sdbDevOutMtKWhTotal
Total kWh value of an outlet. This value can not be reset.
|
kWhKiloWattHour Textual Convention: KiloWattHour Integer32Type Constraints: range: 0..16777215 |
.1.3.6.1.4.1.31034.12.1.1.2.7.2.1.2 |
|
sdbDevOutMtKWhSubtotal
Subotal kWh value of an outlet. This value can be reset.
|
kWhKiloWattHour Textual Convention: KiloWattHour Integer32Type Constraints: range: 0..16777215 |
.1.3.6.1.4.1.31034.12.1.1.2.7.2.1.3 |
|
sdbDevOutMtPowerFactor
Power factor of outlet.
The power factor of an AC power system is defined as the ratio of the real or active power to the apparent power and is a number between 0 and 1. This number is expressed as a percentage between … |
%CentiPercent Textual Convention: CentiPercent Integer32Type Constraints: range: 0..10000 |
.1.3.6.1.4.1.31034.12.1.1.2.7.2.1.4 |
|
sdbDevOutMtActualCurrent
Actual apparent, RMS current.
|
ACentiAmpere Textual Convention: CentiAmpere Integer32Type Constraints: range: 0..327680 |
.1.3.6.1.4.1.31034.12.1.1.2.7.2.1.5 |
|
sdbDevOutMtPeakCurrent
Peak apparent, RMS current.
Highest value since last reset of the alerts. |
ACentiAmpere Textual Convention: CentiAmpere Integer32Type Constraints: range: 0..327680 |
.1.3.6.1.4.1.31034.12.1.1.2.7.2.1.6 |
|
sdbDevOutMtActualVoltage
Actual voltage on outlet.
|
VCentiVolt Textual Convention: CentiVolt Integer32Type Constraints: range: 0..327680 |
.1.3.6.1.4.1.31034.12.1.1.2.7.2.1.7 |
|
sdbDevOutMtMaxAmps
Maximum current per outlet.
Should last at least sdbDevStPeakDuration ms before triggering an alert. |
ACentiAmperer/w Textual Convention: CentiAmpere Integer32Type Constraints: range: 0..327680 |
.1.3.6.1.4.1.31034.12.1.1.2.7.2.1.8 |
|
sdbDevOutMtCTRatio
The multiplier to use for the outlet CTs.
|
Integer32r/w Constraints: range: 0-255 |
.1.3.6.1.4.1.31034.12.1.1.2.7.2.1.9 |
|
sdbDevOutMtPowerVoltAmpere
Calculated apparent power.
|
VAInteger32 Constraints: range: 0-327680 |
.1.3.6.1.4.1.31034.12.1.1.2.7.2.1.10 |
|
sdbDevOutMtPowerWatt
Calculated real power.
|
WInteger32 Constraints: range: 0-327680 |
.1.3.6.1.4.1.31034.12.1.1.2.7.2.1.11 |
sdbDevOutSwTable
table.1.3.6.1.4.1.31034.12.1.1.2.7.3
·
1 row entry
·
6 columns
A table containing information of switched outlets of devices connected to the databus.
Switched outlets entry containing objects of a switched outlet of a
particular databus device.
Note that this table has two indexes. sdbDevIdIndex to identify a
particular device and sdbDevOutSwIndex to identify a parti…
particular databus device.
Note that this table has two indexes. sdbDevIdIndex to identify a
particular device and sdbDevOutSwIndex to identify a parti…
Indexes
sdbDevIdIndex sdbDevOutSwIndex
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
sdbDevOutSwIndex
A unique value for each outlet. Its value ranges between 1 and the
value of sdbDevCfOutletsSwitched. |
Integer32 Constraints: range: 1-54 |
.1.3.6.1.4.1.31034.12.1.1.2.7.3.1.1 |
||||
|
sdbDevOutSwCurrentState
The actual state of the outlet relay.
Note that Writing is only effective after setting sdbDevOutSwUnlock. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.31034.12.1.1.2.7.3.1.2 |
||||
|
sdbDevOutSwScheduled
A one indicates pending activity; the switch delay has not yet
expired. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.31034.12.1.1.2.7.3.1.3 |
||||
|
sdbDevOutSwUnlock
Switching and rebooting is unlocked for 10 seconds by writing a 1.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.31034.12.1.1.2.7.3.1.4 |
||||
|
sdbDevOutSwIndividualOutletDelay
Delay before an individual outlet switches on at power-up.
|
sInteger32r/w Constraints: range: 0-65535 |
.1.3.6.1.4.1.31034.12.1.1.2.7.3.1.5 |
||||
|
sdbDevOutSwReboot
Reboot outlet relay if current state is on and outlet is unlocked;
The outlet will be turned on after 10 seconds. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.31034.12.1.1.2.7.3.1.6 |
sdbDevMeasuresTable
table.1.3.6.1.4.1.31034.12.1.1.2.8.1
·
1 row entry
·
6 columns
A table containing information of temperatures of devices connected to the databus.
Device measures entry containing temperature information objects of a
particular databus device.
particular databus device.
Indexes
sdbDevIdIndex
| Column | Syntax | OID |
|---|---|---|
|
sdbDevMsIntTemperature
Actual internal device temperature in deg C
|
degrees CelsiusCentiCelsius Textual Convention: CentiCelsius Integer32Type Constraints: range: 0..9900 |
.1.3.6.1.4.1.31034.12.1.1.2.8.1.1.1 |
|
sdbDevMsExtTemperature
Actual external device temperature sensor in deg C.
|
degrees CelsiusCentiCelsius Textual Convention: CentiCelsius Integer32Type Constraints: range: 0..9900 |
.1.3.6.1.4.1.31034.12.1.1.2.8.1.1.2 |
|
sdbDevMsIntTemperaturePeak
Peak internal device temperature since last reset of alerts.
|
degrees CelsiusCentiCelsius Textual Convention: CentiCelsius Integer32Type Constraints: range: 0..9900 |
.1.3.6.1.4.1.31034.12.1.1.2.8.1.1.3 |
|
sdbDevMsExtTemperaturePeak
Peak external device temperature since last reset of alerts.
|
degrees CelsiusCentiCelsius Textual Convention: CentiCelsius Integer32Type Constraints: range: 0..9900 |
.1.3.6.1.4.1.31034.12.1.1.2.8.1.1.4 |
|
sdbDevMsResidualCurrent
Residual current.
|
ACentiAmpere Textual Convention: CentiAmpere Integer32Type Constraints: range: 0..327680 |
.1.3.6.1.4.1.31034.12.1.1.2.8.1.1.5 |
|
sdbDevMsResidualPeak
Peak residual current.
|
ACentiAmpere Textual Convention: CentiAmpere Integer32Type Constraints: range: 0..327680 |
.1.3.6.1.4.1.31034.12.1.1.2.8.1.1.6 |
sdbDevSnsTable
table.1.3.6.1.4.1.31034.12.1.1.2.8.2
·
1 row entry
·
4 columns
A table containing information of sensors of devices connected to the databus.
Sensors entry containing objects of a sensor of a particular databus
device.
Note that this table has two indexes. sdbDevIdIndex to identify a
particular device and sdbDevSnsIndex to identify a particular sensor
of the …
device.
Note that this table has two indexes. sdbDevIdIndex to identify a
particular device and sdbDevSnsIndex to identify a particular sensor
of the …
Indexes
sdbDevIdIndex sdbDevSnsIndex
| Column | Syntax | OID |
|---|---|---|
|
sdbDevSnsIndex
A unique value for each sensor. Its value ranges between 1 and the
value of sdbDevCfSensors. |
Integer32 Constraints: range: 1-16 |
.1.3.6.1.4.1.31034.12.1.1.2.8.2.1.1 |
|
sdbDevSnsType
Type of connected sensor.
T = Temperature (C) H = Humidity (%) I = dry switch contact |
OctetString Constraints: range: 1-1 |
.1.3.6.1.4.1.31034.12.1.1.2.8.2.1.2 |
|
sdbDevSnsValue
Value of connected sensor
|
Integer32 Constraints: range: 0-327680 |
.1.3.6.1.4.1.31034.12.1.1.2.8.2.1.3 |
|
sdbDevSnsName
User definable name for sensors.
|
OctetStringr/w Constraints: range: 0-18 |
.1.3.6.1.4.1.31034.12.1.1.2.8.2.1.4 |
sdbDevPerformanceTable
table.1.3.6.1.4.1.31034.12.1.1.2.9.1
·
1 row entry
·
5 columns
A table containing information of sensors of devices connected to the databus.
Performance counters of a particular databus device.
Note that this table has two indexes. sdbDevIdIndex to identify a
particular device and sdbDevPerformanceIndex to identify a particular counter
of the device identifi…
Note that this table has two indexes. sdbDevIdIndex to identify a
particular device and sdbDevPerformanceIndex to identify a particular counter
of the device identifi…
Indexes
sdbDevIdIndex sdbDevPerformanceIndex
| Column | Syntax | OID |
|---|---|---|
|
sdbDevPerformanceIndex
A unique value for each counter. Its value ranges between 1 and 16.
|
Integer32 Constraints: range: 1-16 |
.1.3.6.1.4.1.31034.12.1.1.2.9.1.1.1 |
|
sdbDevPerformanceValue
Value of counter
|
Integer32 Constraints: range: 0-16777215 |
.1.3.6.1.4.1.31034.12.1.1.2.9.1.1.2 |
|
sdbDevPerformanceMax
Max of counter
|
Integer32 Constraints: range: 0-16777215 |
.1.3.6.1.4.1.31034.12.1.1.2.9.1.1.3 |
|
sdbDevPerformanceLimit
Limit of counter
|
Integer32 Constraints: range: 0-16777215 |
.1.3.6.1.4.1.31034.12.1.1.2.9.1.1.4 |
|
sdbDevPerformanceName
User definable name for counter.
|
OctetStringr/w Constraints: range: 0-12 |
.1.3.6.1.4.1.31034.12.1.1.2.9.1.1.5 |
.1.3.6.1.4.1.31034.12.1.1.2.9.2
·
1 row entry
·
2 columns
A table containing the last reset reason of the device
Setting entry containing settings objects of a particular databus
device.
device.
Indexes
sdbDevIdIndex
| Column | Syntax | OID |
|---|---|---|
|
sdbDevPerformanceResetReason
Last reset reason.
|
OctetStringr/w Constraints: range: 0-64 |
.1.3.6.1.4.1.31034.12.1.1.2.9.2.1.1 |
|
sdbDevResetUptime
Uptime before last reset
|
SNMPv2-SMIUnsigned32 Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.31034.12.1.1.2.9.2.1.2 |
sdbDevBranchTable
table.1.3.6.1.4.1.31034.12.1.1.2.10.1
·
1 row entry
·
14 columns
A table containing information of inputs of devices connected to the databus.
Inputs entry containing objects of an input of a particular databus
device.
Note that this table has two indexes. sdbDevIdIndex to identify a
particular device and sdbDevBranchIndex to identify a particular input
of the…
device.
Note that this table has two indexes. sdbDevIdIndex to identify a
particular device and sdbDevBranchIndex to identify a particular input
of the…
Indexes
sdbDevIdIndex sdbDevBranchIndex
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
sdbDevBranchIndex
A unique value for each input. Its value ranges between 1 and the
value of sdbDevCfPhases. |
Integer32 Constraints: range: 1-54 |
.1.3.6.1.4.1.31034.12.1.1.2.10.1.1.1 |
||||
|
sdbDevBranchKWhTotal
Total kWh value of an input. This value can not be reset.
|
kWhKiloWattHour Textual Convention: KiloWattHour Integer32Type Constraints: range: 0..16777215 |
.1.3.6.1.4.1.31034.12.1.1.2.10.1.1.2 |
||||
|
sdbDevBranchKWhSubtotal
Subtotal kWh value of an input. This value can be reset.
|
kWhKiloWattHour Textual Convention: KiloWattHour Integer32Type Constraints: range: 0..16777215 |
.1.3.6.1.4.1.31034.12.1.1.2.10.1.1.3 |
||||
|
sdbDevBranchPowerFactor
Power factor of input.
The power factor of an AC power system is defined as the ratio of the real or active power to the apparent power and is a number between 0 and 1. This value is expressed as a percentage between 0%… |
%CentiPercent Textual Convention: CentiPercent Integer32Type Constraints: range: 0..10000 |
.1.3.6.1.4.1.31034.12.1.1.2.10.1.1.4 |
||||
|
sdbDevBranchActualCurrent
Actual apparent, RMS current.
|
ACentiAmpere Textual Convention: CentiAmpere Integer32Type Constraints: range: 0..327680 |
.1.3.6.1.4.1.31034.12.1.1.2.10.1.1.5 |
||||
|
sdbDevBranchPeakCurrent
Peak apparent, RMS current.
Highest value since last reset of the alerts. |
ACentiAmpere Textual Convention: CentiAmpere Integer32Type Constraints: range: 0..327680 |
.1.3.6.1.4.1.31034.12.1.1.2.10.1.1.6 |
||||
|
sdbDevBranchActualVoltage
The actual voltage.
|
VCentiVolt Textual Convention: CentiVolt Integer32Type Constraints: range: 0..327680 |
.1.3.6.1.4.1.31034.12.1.1.2.10.1.1.7 |
||||
|
sdbDevBranchMinVoltage
RMS voltage dip.
Lowest value since reset of alerts. |
VCentiVolt Textual Convention: CentiVolt Integer32Type Constraints: range: 0..327680 |
.1.3.6.1.4.1.31034.12.1.1.2.10.1.1.8 |
||||
|
sdbDevBranchPowerVoltAmpere
Calculated apparent power.
|
VAInteger32 Constraints: range: 0-327680 |
.1.3.6.1.4.1.31034.12.1.1.2.10.1.1.9 |
||||
|
sdbDevBranchPowerWatt
Calculated real power.
|
WInteger32 Constraints: range: 0-327680 |
.1.3.6.1.4.1.31034.12.1.1.2.10.1.1.10 |
||||
|
sdbDevBranchMaxAmps
Maximum current per input phase.
Should last at least sdbDevStPeakDuration ms before triggering an alert. |
ACentiAmperer/w Textual Convention: CentiAmpere Integer32Type Constraints: range: 0..327680 |
.1.3.6.1.4.1.31034.12.1.1.2.10.1.1.11 |
||||
|
sdbDevBranchCTRatio
The multiplier to use for the input CTs.
|
Integer32r/w Constraints: range: 0-255 |
.1.3.6.1.4.1.31034.12.1.1.2.10.1.1.12 |
||||
|
sdbDevBranchName
User configurable naming of branches.
|
OctetStringr/w Constraints: range: 0-8 |
.1.3.6.1.4.1.31034.12.1.1.2.10.1.1.13 |
||||
|
sdbDevBranchZeroKWhSubtotal
Reset input kWh subtotal counter of a single input to zero.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.31034.12.1.1.2.10.1.1.14 |
sdbDevTotalsTable
table.1.3.6.1.4.1.31034.12.1.1.2.11.1
·
1 row entry
·
11 columns
A table containing information of inputs of devices connected to the databus.
Inputs entry containing objects of an input of a particular databus
device.
Note that this table has two indexes. sdbDevIdIndex to identify a
particular device and sdbDevTotalsIndex to identify a particular input
of the…
device.
Note that this table has two indexes. sdbDevIdIndex to identify a
particular device and sdbDevTotalsIndex to identify a particular input
of the…
Indexes
sdbDevIdIndex sdbDevTotalsIndex
| Column | Syntax | OID |
|---|---|---|
|
sdbDevTotalsIndex
A unique value for each input. Its value ranges between 1 and the
value of sdbDevCfPhases. |
Integer32 Constraints: range: 1-54 |
.1.3.6.1.4.1.31034.12.1.1.2.11.1.1.1 |
|
sdbDevTotalsKWhTotal
Total kWh value of an input. This value can not be reset.
|
kWhKiloWattHour Textual Convention: KiloWattHour Integer32Type Constraints: range: 0..16777215 |
.1.3.6.1.4.1.31034.12.1.1.2.11.1.1.2 |
|
sdbDevTotalsPowerFactor
Power factor of input.
The power factor of an AC power system is defined as the ratio of the real or active power to the apparent power and is a number between 0 and 1. This value is expressed as a percentage between 0%… |
%CentiPercent Textual Convention: CentiPercent Integer32Type Constraints: range: 0..10000 |
.1.3.6.1.4.1.31034.12.1.1.2.11.1.1.3 |
|
sdbDevTotalsActualCurrent
Actual apparent, RMS current.
|
ACentiAmpere Textual Convention: CentiAmpere Integer32Type Constraints: range: 0..327680 |
.1.3.6.1.4.1.31034.12.1.1.2.11.1.1.4 |
|
sdbDevTotalsPeakCurrent
Peak apparent, RMS current.
Highest value since last reset of the alerts. |
ACentiAmpere Textual Convention: CentiAmpere Integer32Type Constraints: range: 0..327680 |
.1.3.6.1.4.1.31034.12.1.1.2.11.1.1.5 |
|
sdbDevTotalsPowerVoltAmpere
Calculated apparent power.
|
VAInteger32 Constraints: range: 0-327680 |
.1.3.6.1.4.1.31034.12.1.1.2.11.1.1.6 |
|
sdbDevTotalsPowerWatt
Calculated real power.
|
WInteger32 Constraints: range: 0-327680 |
.1.3.6.1.4.1.31034.12.1.1.2.11.1.1.7 |
|
sdbDevTotalsNeutralCurrent
Neutral current of phases.
|
ACentiAmpere Textual Convention: CentiAmpere Integer32Type Constraints: range: 0..327680 |
.1.3.6.1.4.1.31034.12.1.1.2.11.1.1.8 |
|
sdbDevTotalsNeutralPeak
Peak neutral current of phases.
|
ACentiAmpere Textual Convention: CentiAmpere Integer32Type Constraints: range: 0..327680 |
.1.3.6.1.4.1.31034.12.1.1.2.11.1.1.9 |
|
sdbDevTotalsNeutralMaxAmps
Maximum neutral current.
Should last at least sdbDevStPeakDuration ms before triggering an alert. |
ACentiAmperer/w Textual Convention: CentiAmpere Integer32Type Constraints: range: 0..327680 |
.1.3.6.1.4.1.31034.12.1.1.2.11.1.1.10 |
|
sdbDevTotalsResidualMaxAmps
Maximum residual current.
Should last at least sdbDevStPeakDuration ms before triggering an alert. |
ACentiAmperer/w Textual Convention: CentiAmpere Integer32Type Constraints: range: 0..327680 |
.1.3.6.1.4.1.31034.12.1.1.2.11.1.1.11 |