RC-SLPP-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
2
Rows
2
Columns
18
.1.3.6.1.4.1.2272.1.64.1.1.2 · 1 row entry · 3 columns
Table of VLANs for which simple loop detection occur on.
rcSlppVlanEntry entry .1.3.6.1.4.1.2272.1.64.1.1.2.1
SLPP VLAN entry.
Indexes
rcSlppVlanVlanId
Column Syntax OID
rcSlppVlanVlanId
Vlan id for which simple loop detection occurs on.
Integer32
Constraints:
range: 1-4094
.1.3.6.1.4.1.2272.1.64.1.1.2.1.1
rcSlppVlanSlppEnable
Flag to indicate whether the VLAN entry is active or not for SLPP.
SNMPv2-TCTruthValuer/w
Textual Convention: SNMPv2-TCTruthValue Enumeration
Type Values:
1true
2false
.1.3.6.1.4.1.2272.1.64.1.1.2.1.2
rcSlppVlanRowStatus
Used to create/delete entries.
SNMPv2-TCRowStatusr/w
Textual Convention: SNMPv2-TCRowStatus Enumeration
Type Values:
1active
2notInService
3notReady
4createAndGo
5createAndWait
6destroy
.1.3.6.1.4.1.2272.1.64.1.1.2.1.3
.1.3.6.1.4.1.2272.1.64.1.1.3 · 1 row entry · 15 columns
Table of ports for which simple loop detection occurs on.
rcSlppPortEntry entry .1.3.6.1.4.1.2272.1.64.1.1.3.1
SLPP Port entry.
Indexes
rcSlppPortIfIndex
Column Syntax OID
rcSlppPortIfIndex
Port on which simple loop detection occurs on.
IF-MIBInterfaceIndex
Textual Convention: IF-MIBInterfaceIndex Integer32
Type Constraints:
range: 1..2147483647
.1.3.6.1.4.1.2272.1.64.1.1.3.1.1
rcSlppPortPktRxThreshold
Once the number of SLPP packets received on this port reaches this threshold
action will be taken. Normally, the port will be shutdown.
Integer32r/w
Constraints:
range: 1-500
.1.3.6.1.4.1.2272.1.64.1.1.3.1.2
rcSlppPortSlppEnable
Flag to indicate whether the port entry is active or not for SLPP.
SNMPv2-TCTruthValuer/w
Textual Convention: SNMPv2-TCTruthValue Enumeration
Type Values:
1true
2false
.1.3.6.1.4.1.2272.1.64.1.1.3.1.3
rcSlppPortRowStatus
Used to create/delete entries.
SNMPv2-TCRowStatusr/w
Textual Convention: SNMPv2-TCRowStatus Enumeration
Type Values:
1active
2notInService
3notReady
4createAndGo
5createAndWait
6destroy
.1.3.6.1.4.1.2272.1.64.1.1.3.1.4
rcSlppPortIncomingVlanId
Vlan id of the classified packet on the port brought down by
SLPP.
Integer32
Constraints:
range: 1-4094
.1.3.6.1.4.1.2272.1.64.1.1.3.1.5
rcSlppPortSrcNodeType
The src node type of the received slpp Pkt.
Enumeration
Enumerated Values:
0none
1local
2peer
.1.3.6.1.4.1.2272.1.64.1.1.3.1.6
rcSlppPortPktRxCount
Total number of SLPP packets received on the port
Integer32
Constraints:
range: 1-500
.1.3.6.1.4.1.2272.1.64.1.1.3.1.7
rcSlppPortGuardEnable
Flag to indicate if SLPP-guard is enabled on the port.
SNMPv2-TCTruthValuer/w
Textual Convention: SNMPv2-TCTruthValue Enumeration
Type Values:
1true
2false
.1.3.6.1.4.1.2272.1.64.1.1.3.1.8
rcSlppPortGuardTimeout
This value specifies the time period for which a port will remain
disabled. When SLPP-guard disables a port, after this time period
expires, the port will become re-enabled. A value of 0 means ports
will never be re-e…
Integer32r/w
Constraints:
range: 0-0
range: 10-65535
.1.3.6.1.4.1.2272.1.64.1.1.3.1.9
rcSlppPortGuardStatus
The object indicates the SLPP-guard status of a port.
Enumeration
Enumerated Values:
1none
2monitoring
3blocking
.1.3.6.1.4.1.2272.1.64.1.1.3.1.10
rcSlppPortGuardTimerCount
This value specifies the time period that has passed since
a port was administratively disabled by SLPP-guard. When this
object reaches the timeout value (rcSlppPortGuardTimeout),
the port will become re-enabled.
Integer32
Constraints:
range: 0-65535
.1.3.6.1.4.1.2272.1.64.1.1.3.1.11
rcSlppPortTimeToClrPktRxCount
Time to clear the SLPP Rx PDU counter. This has a
maximum value of 86400 seconds. The timer starts
when SLPP is enabled and port starts receiving SLPP
SLPP PDUs. When the time exceeds this configured value,
the SLPP …
secondsUnsigned32r/w
Constraints:
range: 1-86400
.1.3.6.1.4.1.2272.1.64.1.1.3.1.12
rcSlppPortRemainingTimeToClrPktRxCount
Remaining time to clear the SLPP Rx PDU counter.
secondsUnsigned32
Constraints:
range: 1-86400
.1.3.6.1.4.1.2272.1.64.1.1.3.1.13
rcSlppPortClearPktRxCount
Clear the SLPP Rx PDU counter.
SNMPv2-TCTruthValuer/w
Textual Convention: SNMPv2-TCTruthValue Enumeration
Type Values:
1true
2false
.1.3.6.1.4.1.2272.1.64.1.1.3.1.14
rcSlppPortGuardOrigin
Indicates how slpp guard was configured.
Supported values:
config - set by user
radius - set by radius atribute
Bits
Enumerated Values:
0config
1radius
.1.3.6.1.4.1.2272.1.64.1.1.3.1.15