MX-HARDWARE-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
5
Rows
5
Columns
28
.0.40000.1.2000.100 · 1 row entry · 3 columns
PRI Ports Status
          
This table displays the status of each PRI port.
portsStatusEntry entry .0.40000.1.2000.100.1
A row in table PRI Ports Status.
Indexes
portsStatusPort
Column Syntax OID
portsStatusPort
Port

Indicates the name of the port.
OctetString .0.40000.1.2000.100.1.100
portsStatusLineType
Line Type

Defines the line type.
Enumeration
Enumerated Values:
100e1
200t1
.0.40000.1.2000.100.1.300
portsStatusSignaling
Signaling

Defines the signaling protocol used by this port.
Enumeration
Enumerated Values:
100isdn
200r2
300eam
.0.40000.1.2000.100.1.400
.0.40000.1.2000.200 · 1 row entry · 3 columns
PRI Ports Configuration
          
The settings of each PRI port are configured in this table.
portsEntry entry .0.40000.1.2000.200.1
A row in table PRI Ports Configuration.
Indexes
portsPort
Column Syntax OID
portsPort
Port

Indicates the name of the port.
OctetString .0.40000.1.2000.200.1.100
portsLineType
Line Type

Defines the line type.

* T1: DS1 T-Carrier Signaling
* E1: E1 E-Carrier Signaling

Note: The value T1 is not valid when the Ports.Signaling
parameter is set to R…
Enumerationr/w
Enumerated Values:
100e1
200t1
.0.40000.1.2000.200.1.300
portsSignaling
Signaling

Defines the signaling protocol used by this port.

* Isdn: Integrated Services Digital Network
* R2: E1-R2 CAS signaling protocol.
* Eam: E&M CAS signaling protocol.
Enumerationr/w
Enumerated Values:
100isdn
200r2
300eam
.0.40000.1.2000.200.1.400
.0.40000.1.2000.1000.100 · 1 row entry · 18 columns
Statistics table of each PRI port.
statsInfoEntry entry .0.40000.1.2000.1000.100.1
A row in table .
Indexes
statsInfoPort
Column Syntax OID
statsInfoPort
Port

The name of the port.
OctetString .0.40000.1.2000.1000.100.1.100
statsInfoFramesTransmitted
Frames Transmitted

Number of HDLC frames transmitted.

Note: Frames do not refer to the structure defined in I.431.
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.0.40000.1.2000.1000.100.1.200
statsInfoFramesReceived
Frames Received

Number of HDLC frames received.

Note: Frames do not refer to the structure defined in I.431.
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.0.40000.1.2000.1000.100.1.300
statsInfoOctetsTransmitted
Octets Transmitted

Number of octets transmitted. This value is obtained by
cumulating the octets transmitted in the HDLC frames.

Note: Frames do not refer to the structure defined in I.431.
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.0.40000.1.2000.1000.100.1.400
statsInfoOctetsReceived
Octets Received

Number of octets received. This value is obtained by
cumulating the octets received in the HDLC frames.

Note: Frames do not refer to the structure defined in I.431.
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.0.40000.1.2000.1000.100.1.500
statsInfoFcsErrors
FCS Errors

Frame check sequence (FCS) errors indicate that frames of
data are being corrupted during transmission. FCS error count
is the number of frames that were received with a bad
checksum (CRC value…
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.0.40000.1.2000.1000.100.1.600
statsInfoFramesDropped
Frames Dropped

Number of frames dropped. This value is obtained by
cumulating the number of frames dropped when transferring
data from the framer chip to the device internal buffer.

This va…
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.0.40000.1.2000.1000.100.1.700
statsInfoOctetsDropped
Octets Dropped

Number of octets dropped. This value is obtained by
cumulating the number of octets dropped when transferring
data from the framer chip to the device internal buffer.

This va…
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.0.40000.1.2000.1000.100.1.800
statsInfoNegativeFrameSlipsTransmitted
Negative Frame Slips Transmitted

A frame is skipped when the frequency of the transmit clock
is greater than the frequency of the transmit system
interface working clock (2.048 MHz on E1 or 1.544 MHz on T…
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.0.40000.1.2000.1000.100.1.900
statsInfoNegativeFrameSlipsReceived
Negative Frame Slips Received

A frame is skipped when the frequency of the received route
clock is greater than the frequency of the receive system
interface working clock (2.048 MHz on E1 or 1.544 MHz on…
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.0.40000.1.2000.1000.100.1.1000
statsInfoPositiveFrameSlipsTransmitted
Positive Frame Slips Transmitted

A frame is repeated when the frequency of the transmit clock
is less than the frequency of the transmit system interface
working clock (2.048 MHz on E1 or 1.544 MHz on T1)…
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.0.40000.1.2000.1000.100.1.1100
statsInfoPositiveFrameSlipsReceived
Positive Frame Slips Received

A frame is repeated when the frequency of the receive route
clock is less than the frequency of the receive system
interface working clock (2.048 MHz on E1 or 1.544 MHz on T1…
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.0.40000.1.2000.1000.100.1.1200
statsInfoFramingErrors
Framing Error

The framing error count indicates that a FAS (Frame Alignment
Signal) word has been received with an error.

The FAS-bits are present in every even frame of timeslot 0 on
E1.
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.0.40000.1.2000.1000.100.1.1300
statsInfoCodeViolations
Code Violations

The code violations count indicates that an encoding error on
the PCM line has been detected.

This value is available on E1 and T1.
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.0.40000.1.2000.1000.100.1.1400
statsInfoCRCErrors
CRC Errors

The CRC errors count is incremented when a multiframe has
been received with a CRC error.

On E1, this counter is only available with the CRC line
framing format.

O…
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.0.40000.1.2000.1000.100.1.1500
statsInfoEBitErrors
E-Bit Error

The E-Bit error count gives information about the outgoing
transmit PCM line if the E-bits are used by the remote end
for submultiframe error indication. Incrementing is only
possible in the m…
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.0.40000.1.2000.1000.100.1.1600
statsInfoBlockErrors
Block Error

The Block Error count is incremented once per multiframe if a
multiframe has been received with a CRC error or if a bad
frame alignment has been detected.

This value is only ava…
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.0.40000.1.2000.1000.100.1.1700
statsInfoResetStats
Reset Stats

Resets all statistics for the specified interface.
Enumerationr/w
Enumerated Values:
0noOp
10resetStats
.0.40000.1.2000.1000.100.1.10000
.0.40000.1.3000.100 · 1 row entry · 2 columns
BRI Ports Status
          
This table displays the status of each BRI port.
briPortsStatusEntry entry .0.40000.1.3000.100.1
A row in table BRI Ports Status.
Indexes
briPortsStatusPort
Column Syntax OID
briPortsStatusPort
Port

Indicates the name of the port.
OctetString .0.40000.1.3000.100.1.100
briPortsStatusPowerFeeding
Power Feeding State

Indicates the state of the power feeding for the port.

* On: Power is fed to the line.
* Off: Power is not fed to the line.
* Unavailable: The power feeding featur…
Enumeration
Enumerated Values:
100on
200off
300unavailable
400unsupported
.0.40000.1.3000.100.1.200
.0.40000.1.3000.200 · 1 row entry · 2 columns
BRI Ports Configuration
          
The settings of each BRI port are configured in this table.
briPortsEntry entry .0.40000.1.3000.200.1
A row in table BRI Ports Configuration.
Indexes
briPortsPort
Column Syntax OID
briPortsPort
Port

Indicates the name of the port.
OctetString .0.40000.1.3000.200.1.100
briPortsPowerFeedingEnable
Power Feeding Enable

Enables or disables the power feeding for the port.
MX-TCMxEnableStater/w
Textual Convention: MX-TCMxEnableState Enumeration
Type Values:
0disable
1enable
.0.40000.1.3000.200.1.200