statsInfoEBitErrors

MX-HARDWARE-MIB · .0.40000.1.2000.1000.100.1.1600

Object

column SNMPv2-SMIUnsigned32
E-Bit Error
              
The E-Bit error count gives information about the outgoing
transmit PCM line if the E-bits are used by the remote end
for submultiframe error indication. Incrementing is only
possible in the multiframe synchronous state.
              
Due to signaling requirements, the E-bits of frame 13 and
frame 15 of the CRC multiframe can be used to indicate an
error in a received submultiframes:
              
  * Submultiframe I status E-bit located in frame 13
  * Submultiframe II status E-bit located in frame 15
  * no CRC error: E = 1
  * CRC error: E = 0
              
This value is only available in E1.

Context

MIB
MX-HARDWARE-MIB
OID
.0.40000.1.2000.1000.100.1.1600
Type
column
Access
readonly
Status
current
Parent
statsInfoEntry
Table
statsInfoTable
Siblings
17

Syntax

SNMPv2-SMIUnsigned32
Source
SNMPv2-SMIUnsigned32
Base type
Unsigned32

Values & Constraints

Type Constraints
range: 0..4294967295

Related Objects

Sibling Objects