IEEE8021-ST-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
2
Rows
2
Columns
25
.1.3.111.2.802.1.1.30.1.1.1 · 1 row entry · 3 columns
A table containing a set of max SDU 
parameters, one for each traffic class.
All writeable objects in this table must be
persistent over power up restart/reboot.
ieee8021STMaxSDUEntry entry .1.3.111.2.802.1.1.30.1.1.1.1
A list of objects containing Max SDU size
for each traffic class supported by the Port.
Indexes
IEEE8021-BRIDGE-MIBieee8021BridgeBaseComponentId IEEE8021-BRIDGE-MIBieee8021BridgeBasePort ieee8021STTrafficClass
Column Syntax OID
ieee8021STTrafficClass
The traffic class number associated with the row of
the table.

A row in this table is created for each traffic class
that is supported by the Port
IEEE8021STTrafficClassValue
Textual Convention: IEEE8021STTrafficClassValue Unsigned32
Type Constraints:
range: 0..7
.1.3.111.2.802.1.1.30.1.1.1.1.1
ieee8021STMaxSDU
The value of the MaxSDU parameter for the traffic class.
This value is represented as an unsigned integer. A value
of 0 is interpreted as the max SDU size supported by
the underlying MAC.

The default valu…
octetsSNMPv2-SMIUnsigned32r/w
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.111.2.802.1.1.30.1.1.1.1.2
ieee8021TransmissionOverrun
A counter of transmission overrun events, where
a PDU is still being transmitted by a MAC at the
time when the transmission gate for the queue closed.
SNMPv2-SMICounter64
Textual Convention: SNMPv2-SMICounter64 Unsigned64
Type Constraints:
range: 0..18446744073709551615
.1.3.111.2.802.1.1.30.1.1.1.1.3
.1.3.111.2.802.1.1.30.1.2.1 · 1 row entry · 22 columns
A table that contains the per-port manageable parameters for 
traffic scheduling.
          
For a given Port, a row in the table exists.
          
All writable objects in this table must be
persistent over power up restart/reboot.
ieee8021STParametersEntry entry .1.3.111.2.802.1.1.30.1.2.1.1
A list of objects that contains the manageable parameters for
traffic scheduling for a port.
Indexes
IEEE8021-BRIDGE-MIBieee8021BridgeBaseComponentId IEEE8021-BRIDGE-MIBieee8021BridgeBasePort
Column Syntax OID
ieee8021STGateEnabled
The GateEnabled parameter determines whether traffic scheduling
is active (true) or inactive (false).

The value of this object MUST be retained across
reinitializations of the management system.
SNMPv2-TCTruthValuer/w
Textual Convention: SNMPv2-TCTruthValue Enumeration
Type Values:
1true
2false
.1.3.111.2.802.1.1.30.1.2.1.1.1
ieee8021STAdminGateStates
The administrative value of the GateStates parameter for the Port.
The bits of the octet represent the gate states for the
corresponding traffic classes; the MS bit corresponds to traffic class 7,
the LS bit to traffic…
OctetStringr/w
Constraints:
range: 1-1
.1.3.111.2.802.1.1.30.1.2.1.1.2
ieee8021STOperGateStates
The operational value of the GateStates parameter for the Port.
The bits of the octet represent the gate states for the
corresponding traffic classes; the MS bit corresponds to traffic class 7,
the LS bit to traffic cl…
OctetString
Constraints:
range: 1-1
.1.3.111.2.802.1.1.30.1.2.1.1.3
ieee8021STAdminControlListLength
The administrative value of the ListMax parameter for the Port.
The integer value indicates the number of entries (TLVs) in the
AdminControlList.

The value of this object MUST be retained across
reinitial…
SNMPv2-SMIUnsigned32r/w
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.111.2.802.1.1.30.1.2.1.1.4
ieee8021STOperControlListLength
The operational value of the ListMax parameter for the Port.
The integer value indicates the number of entries (TLVs) in the
OperControlList.
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.111.2.802.1.1.30.1.2.1.1.5
ieee8021STAdminControlList
The administrative value of the ControlList parameter for the Port.
The octet string value represents the contents of the control list as
an ordered list of entries, each encoded as a TLV, as follows.
The first octet o…
OctetStringr/w .1.3.111.2.802.1.1.30.1.2.1.1.6
ieee8021STOperControlList
The operational value of the ListMax parameter for the Port.
The octet string value represents the contents of the control list as
an ordered list of TLVs, as follows.
The first octet of each TLV is interpreted as a ga…
OctetString .1.3.111.2.802.1.1.30.1.2.1.1.7
ieee8021STAdminCycleTimeNumerator
The administrative value of the numerator of the CycleTime
parameter for the Port.
The numerator and denominator together represent the cycle time as
a rational number of seconds.

The value of this object…
SNMPv2-SMIUnsigned32r/w
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.111.2.802.1.1.30.1.2.1.1.8
ieee8021STAdminCycleTimeDenominator
The administrative value of the denominator of the
CycleTime parameter for the Port.
The numerator and denominator together represent the cycle time as
a rational number of seconds.

The value of this obj…
SNMPv2-SMIUnsigned32r/w
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.111.2.802.1.1.30.1.2.1.1.9
ieee8021STOperCycleTimeNumerator
The operational value of the numerator of the
CycleTime parameter for the Port.
The numerator and denominator together represent the cycle
time as a rational number of seconds.
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.111.2.802.1.1.30.1.2.1.1.10
ieee8021STOperCycleTimeDenominator
The operational value of the denominator of the
CycleTime parameter for the Port.
The numerator and denominator together represent the
cycle time as a rational number of seconds.
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.111.2.802.1.1.30.1.2.1.1.11
ieee8021STAdminCycleTimeExtension
The administrative value of the CycleTimeExtension
parameter for the Port.
The value is an unsigned integer number of nanoseconds.

The value of this object MUST be retained across
reinitializations of t…
nanosecondsSNMPv2-SMIUnsigned32r/w
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.111.2.802.1.1.30.1.2.1.1.12
ieee8021STOperCycleTimeExtension
The operational value of the CycleTimeExtension parameter for the Port.
The value is an unsigned integer number of nanoseconds.
nanosecondsSNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.111.2.802.1.1.30.1.2.1.1.13
ieee8021STAdminBaseTime
The administrative value of the BaseTime parameter for the Port.
The value is a representation of a PTPtime value,
consisting of a 48-bit integer
number of seconds and a 32-bit integer number of nanoseconds.
PTP timeIEEE8021STPTPtimeValuer/w
Textual Convention: IEEE8021STPTPtimeValue OctetString
Type Constraints:
range: 10
.1.3.111.2.802.1.1.30.1.2.1.1.14
ieee8021STOperBaseTime
The operationsl value of the BaseTime parameter for the Port.
The value is a representation of a PTPtime value,
consisting of a 48-bit integer
number of seconds and a 32-bit integer number of nanoseconds.
PTP timeIEEE8021STPTPtimeValue
Textual Convention: IEEE8021STPTPtimeValue OctetString
Type Constraints:
range: 10
.1.3.111.2.802.1.1.30.1.2.1.1.15
ieee8021STConfigChange
The ConfigChange parameter signals the start of a
configuration change
when it is set to TRUE. This should only be done
when the various administrative parameters
are all set to appropriate values.
SNMPv2-TCTruthValuer/w
Textual Convention: SNMPv2-TCTruthValue Enumeration
Type Values:
1true
2false
.1.3.111.2.802.1.1.30.1.2.1.1.16
ieee8021STConfigChangeTime
The PTPtime at which the next config change is scheduled to occur.
The value is a representation of a PTPtime value,
consisting of a 48-bit integer
number of seconds and a 32-bit integer number of nanoseconds.
PTP timeIEEE8021STPTPtimeValue
Textual Convention: IEEE8021STPTPtimeValue OctetString
Type Constraints:
range: 10
.1.3.111.2.802.1.1.30.1.2.1.1.17
ieee8021STTickGranularity
The granularity of the cycle time clock, represented as an
unsigned number of tenths of nanoseconds.

The value of this object MUST be retained across
reinitializations of the management system.
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.111.2.802.1.1.30.1.2.1.1.18
ieee8021STCurrentTime
The current time, in PTPtime, as maintained by the local system.
The value is a representation of a PTPtime value,
consisting of a 48-bit integer
number of seconds and a 32-bit integer number of nanoseconds.
IEEE8021STPTPtimeValue
Textual Convention: IEEE8021STPTPtimeValue OctetString
Type Constraints:
range: 10
.1.3.111.2.802.1.1.30.1.2.1.1.19
ieee8021STConfigPending
The value of the ConfigPending state machine variable.
The value is TRUE if a configuration change is in progress
but has not yet completed.
SNMPv2-TCTruthValue
Textual Convention: SNMPv2-TCTruthValue Enumeration
Type Values:
1true
2false
.1.3.111.2.802.1.1.30.1.2.1.1.20
ieee8021STConfigChangeError
A counter of the number of times that a re-configuration
of the traffic schedule has been requested with the old
schedule still running and the requested base time was
in the past.
SNMPv2-SMICounter64
Textual Convention: SNMPv2-SMICounter64 Unsigned64
Type Constraints:
range: 0..18446744073709551615
.1.3.111.2.802.1.1.30.1.2.1.1.21
ieee8021STSupportedListMax
The maximum value supported by this Port of the
AdminControlListLength and OperControlListLength
parameters.
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.111.2.802.1.1.30.1.2.1.1.22