ieee8021STOperControlList

IEEE8021-ST-MIB · .1.3.111.2.802.1.1.30.1.2.1.1.7

Object

column OctetString
The operational value of the ListMax parameter for the Port.
The octet string value represents the contents of the control list as
an ordered list of TLVs, as follows.
The first octet  of each TLV is interpreted as a gate operation name:
    0: SetGateStates
    1: Set-And-Hold-MAC
    2: Set-And-Release-MAC
    3-255: Reserved for future gate operations
                  
The second octet of the TLV is the length field, 
interpreted as an unsigned integer,
indicating the number of octets of the value that follows
the length. A length of zero indicates that there is no value 
(i.e., the gate operation has no parameters).
              
The third through (3 + length -1)th octets encode the 
parameters of the gate operation, in the order that they 
appear in the definition of the operation
in Table 8-6. Two parameter types are currently defined:
              
- GateState:
    A GateState parameter is encoded in a single octet.
    The bits of the octet represent the gate states for the 
    corresponding traffic classes; the MS bit corresponds to
    traffic class 7, the LS bit to traffic class 0. 
    A bit value of 0 indicates closed; a 
    bit value of 1 indicates open.
                  
- TimeInterval: 
    A TimeInterval is encoded in 4 octets as a 32-bit 
    unsigned integer, representing
    a number of nanoseconds. The first octet encodes the
    most significant 8 bits of the integer, and the fourth
    octet encodes the least significant 8 bits.

Context

MIB
IEEE8021-ST-MIB
OID
.1.3.111.2.802.1.1.30.1.2.1.1.7
Type
column
Access
readonly
Status
current
Parent
ieee8021STParametersEntry
Table
ieee8021STParametersTable
Siblings
21

Syntax

OctetString

Values & Constraints

No enumerated values or constraints recorded.

Related Objects

Sibling Objects