ieee8021STAdminControlList
IEEE8021-ST-MIB ·
.1.3.111.2.802.1.1.30.1.2.1.1.6
Object
column
r/w
OctetString
The administrative value of the ControlList parameter for the Port.
The octet string value represents the contents of the control list as
an ordered list of entries, each encoded as a TLV, as follows.
The first octet of each TLV is interpreted as an
unsigned integer representing a gate operation name:
0: SetGateStates
1: Set-And-Hold-MAC
2: Set-And-Release-MAC
3-255: Reserved for future gate operations
The second octet of the TLV is the length field,
interpreted as an unsigned integer, indicating the number of
octets of the value that follows the length. A length of
zero indicates that there is no value
(i.e., the gate operation has no parameters).
The third through (3 + length -1)th octets encode the
parameters of the gate operation, in the order that they
appear in the definition of the operation
in Table 8-6. Two parameter types are currently defined:
- GateState:
A GateState parameter is encoded in a single octet.
The bits of the octet represent the gate states for the
corresponding traffic classes; the MS bit corresponds
to traffic class 7,
the LS bit to traffic class 0. A bit value of 0 indicates
closed; a bit value of 1 indicates open.
- TimeInterval:
A TimeInterval is encoded in 4 octets as a 32-bit
unsigned integer, representing a number of nanoseconds.
The first octet encodes the most significant 8 bits of the
integer, and the fourth octet encodes the least
significant 8 bits.
The value of this object MUST be retained across
reinitializations of the management system.
Context
- MIB
- IEEE8021-ST-MIB
- OID
.1.3.111.2.802.1.1.30.1.2.1.1.6- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- ieee8021STParametersEntry
- Table
- ieee8021STParametersTable
- Siblings
- 21
Syntax
OctetString
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| ieee8021STGateEnabled The GateEnabled parameter determines whether traffic scheduling
is active (true) or inactive (false).
The value of this object MUST be retained across
reinitializat… | column | SNMPv2-TCTruthValue | .1.3.111.2.802.1.1.30.1.2.1.1.1 |
| ieee8021STOperCycleTimeNumerator The operational value of the numerator of the
CycleTime parameter for the Port.
The numerator and denominator together represent the cycle
time as a rational number of seconds. | column | SNMPv2-SMIUnsigned32 | .1.3.111.2.802.1.1.30.1.2.1.1.10 |
| ieee8021STOperCycleTimeDenominator The operational value of the denominator of the
CycleTime parameter for the Port.
The numerator and denominator together represent the
cycle time as a rational number of seconds. | column | SNMPv2-SMIUnsigned32 | .1.3.111.2.802.1.1.30.1.2.1.1.11 |
| ieee8021STAdminCycleTimeExtension The administrative value of the CycleTimeExtension
parameter for the Port.
The value is an unsigned integer number of nanoseconds.
The value of this object MUST b… | column | nanoseconds SNMPv2-SMIUnsigned32 | .1.3.111.2.802.1.1.30.1.2.1.1.12 |
| ieee8021STOperCycleTimeExtension The operational value of the CycleTimeExtension parameter for the Port.
The value is an unsigned integer number of nanoseconds. | column | nanoseconds SNMPv2-SMIUnsigned32 | .1.3.111.2.802.1.1.30.1.2.1.1.13 |
| ieee8021STAdminBaseTime The administrative value of the BaseTime parameter for the Port.
The value is a representation of a PTPtime value,
consisting of a 48-bit integer
number of seconds and a 32-bit i… | column | PTP time IEEE8021STPTPtimeValue | .1.3.111.2.802.1.1.30.1.2.1.1.14 |
| ieee8021STOperBaseTime The operationsl value of the BaseTime parameter for the Port.
The value is a representation of a PTPtime value,
consisting of a 48-bit integer
number of seconds and a 32-bit inte… | column | PTP time IEEE8021STPTPtimeValue | .1.3.111.2.802.1.1.30.1.2.1.1.15 |
| ieee8021STConfigChange The ConfigChange parameter signals the start of a
configuration change
when it is set to TRUE. This should only be done
when the various administrative parameters
are all set to … | column | SNMPv2-TCTruthValue | .1.3.111.2.802.1.1.30.1.2.1.1.16 |
| ieee8021STConfigChangeTime The PTPtime at which the next config change is scheduled to occur.
The value is a representation of a PTPtime value,
consisting of a 48-bit integer
number of seconds and a 32-bit… | column | PTP time IEEE8021STPTPtimeValue | .1.3.111.2.802.1.1.30.1.2.1.1.17 |
| ieee8021STTickGranularity The granularity of the cycle time clock, represented as an
unsigned number of tenths of nanoseconds.
The value of this object MUST be retained across
reinitializati… | column | SNMPv2-SMIUnsigned32 | .1.3.111.2.802.1.1.30.1.2.1.1.18 |
| ieee8021STCurrentTime The current time, in PTPtime, as maintained by the local system.
The value is a representation of a PTPtime value,
consisting of a 48-bit integer
number of seconds and a 32-bit i… | column | IEEE8021STPTPtimeValue | .1.3.111.2.802.1.1.30.1.2.1.1.19 |
| ieee8021STAdminGateStates The administrative value of the GateStates parameter for the Port.
The bits of the octet represent the gate states for the
corresponding traffic classes; the MS bit corresponds t… | column | OctetString | .1.3.111.2.802.1.1.30.1.2.1.1.2 |
| ieee8021STConfigPending The value of the ConfigPending state machine variable.
The value is TRUE if a configuration change is in progress
but has not yet completed. | column | SNMPv2-TCTruthValue | .1.3.111.2.802.1.1.30.1.2.1.1.20 |
| ieee8021STConfigChangeError A counter of the number of times that a re-configuration
of the traffic schedule has been requested with the old
schedule still running and the requested base time was
in the past. | column | SNMPv2-SMICounter64 | .1.3.111.2.802.1.1.30.1.2.1.1.21 |
| ieee8021STSupportedListMax The maximum value supported by this Port of the
AdminControlListLength and OperControlListLength
parameters. | column | SNMPv2-SMIUnsigned32 | .1.3.111.2.802.1.1.30.1.2.1.1.22 |
| ieee8021STOperGateStates The operational value of the GateStates parameter for the Port.
The bits of the octet represent the gate states for the
corresponding traffic classes; the MS bit corresponds to t… | column | OctetString | .1.3.111.2.802.1.1.30.1.2.1.1.3 |
| ieee8021STAdminControlListLength The administrative value of the ListMax parameter for the Port.
The integer value indicates the number of entries (TLVs) in the
AdminControlList.
The value of this … | column | SNMPv2-SMIUnsigned32 | .1.3.111.2.802.1.1.30.1.2.1.1.4 |
| ieee8021STOperControlListLength The operational value of the ListMax parameter for the Port.
The integer value indicates the number of entries (TLVs) in the
OperControlList. | column | SNMPv2-SMIUnsigned32 | .1.3.111.2.802.1.1.30.1.2.1.1.5 |
| ieee8021STOperControlList The operational value of the ListMax parameter for the Port.
The octet string value represents the contents of the control list as
an ordered list of TLVs, as follows.
The first o… | column | OctetString | .1.3.111.2.802.1.1.30.1.2.1.1.7 |
| ieee8021STAdminCycleTimeNumerator The administrative value of the numerator of the CycleTime
parameter for the Port.
The numerator and denominator together represent the cycle time as
a rational number of seconds.… | column | SNMPv2-SMIUnsigned32 | .1.3.111.2.802.1.1.30.1.2.1.1.8 |
| ieee8021STAdminCycleTimeDenominator The administrative value of the denominator of the
CycleTime parameter for the Port.
The numerator and denominator together represent the cycle time as
a rational number of secon… | column | SNMPv2-SMIUnsigned32 | .1.3.111.2.802.1.1.30.1.2.1.1.9 |