.1.3.6.1.4.1.2011.6.15.1.1 · 1 row entry · 67 columns
You can add, delete, modify or query SPC using hwSpcMngtTable.
The index of this table is hwSpcNo.
hwSpcMngtEntry entry .1.3.6.1.4.1.2011.6.15.1.1.1
You can add, delete, modify or query SPC using hwSpcMngtTable.
The index of this entry is hwSpcNo.
Indexes
hwSpcNo
Column Syntax OID
hwSpcNo
Index of the SPC
Range: 0-2047 for MD products and 0-511 for MA products
Integer32
Constraints:
range: 0-2099
.1.3.6.1.4.1.2011.6.15.1.1.1.1
hwStartFrameID
Frame ID of SPC's start point. It must have been described in HUAWEI-DIVICE-MIB.
Integer32r/w
Constraints:
range: 0-97
.1.3.6.1.4.1.2011.6.15.1.1.1.2
hwStartSlotID
Slot ID of SPC's start point. It must have been described in HUAWEI-DIVICE-MIB.
Integer32r/w
Constraints:
range: 0-35
.1.3.6.1.4.1.2011.6.15.1.1.1.3
hwStartPort
Port ID of SPC's start point. It must have been described in HUAWEI-DIVICE-MIB.
Integer32r/w
Constraints:
range: 0-63
.1.3.6.1.4.1.2011.6.15.1.1.1.4
hwStartBsn
Channel index of SPC's start point
Integer32r/w
Constraints:
range: 0-31
.1.3.6.1.4.1.2011.6.15.1.1.1.5
hwEndFrameID
Shelf ID of ANSPC's end point. It must have been described in HUAWEI-DIVICE-MIB.
The value 255 indicates that this parameter is not used.
Integer32r/w
Constraints:
range: 255-255
range: 0-97
.1.3.6.1.4.1.2011.6.15.1.1.1.6
hwEndSlotID
Slot ID of ANSPC's end point. It must have been described in HUAWEI-DIVICE-MIB.
The value 255 indicates that this parameter is not used.
Integer32r/w
Constraints:
range: 255-255
range: 0-35
.1.3.6.1.4.1.2011.6.15.1.1.1.7
hwEndPort
Port ID of ANSPC's end point. It must have been described in HUAWEI-DIVICE-MIB.
The value 255 indicates that this parameter is not used.
Integer32r/w
Constraints:
range: 255-255
range: 0-63
.1.3.6.1.4.1.2011.6.15.1.1.1.8
hwEndBsn
Channel index of SPC's end point.
The value 255 indicates that this parameter is not used.
Integer32r/w
Constraints:
range: 255-255
range: 0-31
.1.3.6.1.4.1.2011.6.15.1.1.1.9
hwChannelNum
Total channels occupied by the SPC.
Integer32r/w
Constraints:
range: 1-32
.1.3.6.1.4.1.2011.6.15.1.1.1.10
hwApptype
Applied type of SPC.
Options:
1. normal(1) -normal application
2. hotline(2) -hotline application
3. mChannelTransparent(3) -M channel transparent
4. pBX-extention(4) -Z interface extension
5. pBX-bothway(5) -PBX bothwa…
Enumerationr/w
Enumerated Values:
1normal
2hotline
3mChannelTransparent
4pBX-extention
5pBX-bothway
6e1-DDI
7t1-DDI
8eM-signal
.1.3.6.1.4.1.2011.6.15.1.1.1.11
hwSpctype
Configuration type of SPC.
Options:
1. anSpc(1) -Internal SPC
2. v5Spc(2) -V5 SPC
3. v5Preconnect(3) -V5 pre-connection SPC
4. private(4) -leased line SPC
5. ipspc(5) -IP SPC
6. confspc(6) -conference SPC
Enumerationr/w
Enumerated Values:
1anSpc
2v5Spc
3v5Preconnect
4private
5ipspc
6confspc
.1.3.6.1.4.1.2011.6.15.1.1.1.12
hwStartPortSubType
Sub type of SPC's start port. If the SPC is used for PHS, the type must be set to mnt or mlt.
Options:
1. noSubType(255) -no sub type
2. mnt(1) -mnt
3. mlt(2) -mlt
Enumerationr/w
Enumerated Values:
1mnt
2mlt
255noSubType
.1.3.6.1.4.1.2011.6.15.1.1.1.13
hwEndPortSubType
Sub type of SPC's end port.
This node is not used on the OLT.
Options:
1. noSubType(255) -no sub type
2. mnt(1) -mnt
3. mlt(2) -mlt
Enumerationr/w
Enumerated Values:
1mnt
2mlt
255noSubType
.1.3.6.1.4.1.2011.6.15.1.1.1.14
hwPathProtect
Enable path protection. This leaf is not used on the OLT.
Options:
1. yes(1) -YES
2. no(2) -NO
Enumerationr/w
Enumerated Values:
1yes
2no
.1.3.6.1.4.1.2011.6.15.1.1.1.15
hwSPCName
Name of SPC. It contains 31 characters.
- means it is not configured.
OctetStringr/w
Constraints:
range: 1-31
.1.3.6.1.4.1.2011.6.15.1.1.1.16
hwSpcState
SPC state.
Options:
1. idle(1) -idle
2. normal(2) -normal
3. error(3) -error
4. errorChecking(4) -error checking
5. occupying(5) -occupying
6. checking(6) -checking
7. released(7) -released
8. errReleasing(8) -error rel…
Enumeration
Enumerated Values:
1idle
2normal
3error
4errorChecking
5occupying
6checking
7released
8errReleasing
9refreshReleasing
10disconnecting
.1.3.6.1.4.1.2011.6.15.1.1.1.17
hwFailCause
Fault reason of SPC.
Options:
1. startBusy(1) -the start port is busy
2. endBusy(2) - the end port is busy
3. startFault(3) - the start port is fault
4. endFault(4) - the end port is fault
5. startLoop(5) - the start po…
Enumeration
Enumerated Values:
1startBusy
2endBusy
3startFault
4endFault
5startLoop
6endLoop
7startLock
8endLock
9resNotEnough
10waitingTimeout
11startTest
12endTest
13noAlarm
14noTS
15noLicense
16linksetFault
17portUnactive
.1.3.6.1.4.1.2011.6.15.1.1.1.18
hwOprType
Operate type of SPC. It can be set to disconnect or connect.
Options:
1. noOperation(1) -no operation
2. connect(2) -connect
3. disconnect(3) -disconnect
Enumerationr/w
Enumerated Values:
1noOperation
2connect
3disconnect
.1.3.6.1.4.1.2011.6.15.1.1.1.19
hwRowStatus
Row status. It supports only CreateAndGo(4) and Destroy(6).
SNMPv2-TCRowStatusr/w
Textual Convention: SNMPv2-TCRowStatus Enumeration
Type Values:
1active
2notInService
3notReady
4createAndGo
5createAndWait
6destroy
.1.3.6.1.4.1.2011.6.15.1.1.1.20
hwStartCESFrame
Start CES shelf.
If the value is 255, it indicates that the SPC does not use this path.
This leaf is not used on the OLT.
Integer32
Constraints:
range: 0-255
.1.3.6.1.4.1.2011.6.15.1.1.1.21
hwStartCESSlot
CES slot.
If the value is 255, it indicates that the SPC does not use this path.
This leaf is not used on the OLT.
Integer32
Constraints:
range: 0-255
.1.3.6.1.4.1.2011.6.15.1.1.1.22
hwStartCESPort
Start CES port.
If the value is 255, it indicates that the SPC does not use this path.
This leaf is not used on the OLT.
Integer32
Constraints:
range: 0-255
.1.3.6.1.4.1.2011.6.15.1.1.1.23
hwStartUpPv8Frame
Start upstream PV8 shelf.
If the value is 255, it indicates that the SPC does not use this path.
This leaf is not used on the OLT.
Integer32
Constraints:
range: 0-255
.1.3.6.1.4.1.2011.6.15.1.1.1.24
hwStartUpPv8Slot
Start upstream PV8 slot.
If the value is 255, it indicates that the SPC does not use this path.
This leaf is not used on the OLT.
Integer32
Constraints:
range: 0-255
.1.3.6.1.4.1.2011.6.15.1.1.1.25
hwStartUpPv8Port
Start upstream PV8 port.
If the value is 255, it indicates that the SPC does not use this path.
This leaf is not used on the OLT.
Integer32
Constraints:
range: 0-255
.1.3.6.1.4.1.2011.6.15.1.1.1.26
hwStartDownPv8Frame
Start downstream PV8 shelf.
If the value is 255, it indicates that the SPC does not use this path.
This leaf is not used on the OLT.
Integer32
Constraints:
range: 0-255
.1.3.6.1.4.1.2011.6.15.1.1.1.27
hwStartDownPv8Slot
Start downstream PV8 slot.
If the value is 255, it indicates that the SPC does not use this path.
This leaf is not used on the OLT.
Integer32
Constraints:
range: 0-255
.1.3.6.1.4.1.2011.6.15.1.1.1.28
hwStartDownPv8Port
Start downstream PV8 port.
If the value is 255, it indicates that the SPC does not use this path.
This leaf is not used on the OLT.
Integer32
Constraints:
range: 0-255
.1.3.6.1.4.1.2011.6.15.1.1.1.29
hwStartRspFrame
Start downstream RSP shelf.
If the value is 255, it indicates that the SPC does not use this path.
This leaf is not used on the OLT.
Integer32
Constraints:
range: 0-255
.1.3.6.1.4.1.2011.6.15.1.1.1.30
hwStartRspSlot
Start downstream RSP slot.
If the value is 255, it indicates that the SPC does not use this path.
This leaf is not used on the OLT.
Integer32
Constraints:
range: 0-255
.1.3.6.1.4.1.2011.6.15.1.1.1.31
hwStartRspPort
Start downstream RSP port.
If the value is 255, it indicates that the SPC does not use this path.
This leaf is not used on the OLT.
Integer32
Constraints:
range: 0-255
.1.3.6.1.4.1.2011.6.15.1.1.1.32
hwEndtCESFrame
End downstream CES shelf.
If the value is 255, it indicates that the SPC does not use this path.
This leaf is not used on the OLT.
Integer32
Constraints:
range: 0-255
.1.3.6.1.4.1.2011.6.15.1.1.1.33
hwEndCESSlot
End downstream CES slot.
If the value is 255, it indicates that the SPC does not use this path.
This leaf is not used on the OLT.
Integer32
Constraints:
range: 0-255
.1.3.6.1.4.1.2011.6.15.1.1.1.34
hwEndCESPort
End CES port.
If the value is 255, it indicates that the SPC does not use this path.
This leaf is not used on the OLT.
Integer32
Constraints:
range: 0-255
.1.3.6.1.4.1.2011.6.15.1.1.1.35
hwEndUpPv8Frame
End upstream PV8 shelf.
If the value is 255, it indicates that the SPC does not use this path.
This leaf is not used on the OLT.
Integer32
Constraints:
range: 0-255
.1.3.6.1.4.1.2011.6.15.1.1.1.36
hwEndUpPv8Slot
End upstream PV8 slot.
If the value is 255, it indicates that the SPC does not use this path.
This leaf is not used on the OLT.
Integer32
Constraints:
range: 0-255
.1.3.6.1.4.1.2011.6.15.1.1.1.37
hwEndUpPv8Port
End upstream PV8 port.
If the value is 255, it indicates that the SPC does not use this path.
This leaf is not used on the OLT.
Integer32
Constraints:
range: 0-255
.1.3.6.1.4.1.2011.6.15.1.1.1.38
hwEndDownPv8Frame
End downstream PV8 shelf.
If the value is 255, it indicates that the SPC does not use this path.
This leaf is not used on the OLT.
Integer32
Constraints:
range: 0-255
.1.3.6.1.4.1.2011.6.15.1.1.1.39
hwEndDownPv8Slot
End downstream PV8 slot.
If the value is 255, it indicates that the SPC does not use this path.
This leaf is not used on the OLT.
Integer32
Constraints:
range: 0-255
.1.3.6.1.4.1.2011.6.15.1.1.1.40
hwEndDownPv8Port
End downstream PV8 port.
If the value is 255, it indicates that the SPC does not use this path.
This leaf is not used on the OLT.
Integer32
Constraints:
range: 0-255
.1.3.6.1.4.1.2011.6.15.1.1.1.41
hwEndRspFrame
End RSP shelf.
If the value is 255, it indicates that the SPC does not use this path.
This leaf is not used on the OLT.
Integer32
Constraints:
range: 0-255
.1.3.6.1.4.1.2011.6.15.1.1.1.42
hwEndRspSlot
End RSP slot.
If the value is 255, it indicates that the SPC does not use this path.
This leaf is not used on the OLT.
Integer32
Constraints:
range: 0-255
.1.3.6.1.4.1.2011.6.15.1.1.1.43
hwEndRspPort
End RSP port.
If the value is 255, it indicates that the SPC does not use this path.
This leaf is not used on the OLT.
Integer32
Constraints:
range: 0-255
.1.3.6.1.4.1.2011.6.15.1.1.1.44
hwIpSpcAttributeLocalIPAddr
Local IP address of the SPC. If the SPC's type is IPSPC, the local IP address must be configured.
SNMPv2-SMIIpAddressr/w
Textual Convention: SNMPv2-SMIIpAddress OctetString
Type Constraints:
range: 4
.1.3.6.1.4.1.2011.6.15.1.1.1.45
hwIpSpcAttributeLocalPort
Local UDP port of the SPC. If the SPC's type is IPSPC, the local UDP port must be configured.
Integer32r/w
Constraints:
range: 0-65535
.1.3.6.1.4.1.2011.6.15.1.1.1.46
hwIpSpcAttributeRemoteIPAddr
Remote IP address of the SPC. If the SPC's type is IPSPC, the remote IP address mustd be configured.
SNMPv2-SMIIpAddressr/w
Textual Convention: SNMPv2-SMIIpAddress OctetString
Type Constraints:
range: 4
.1.3.6.1.4.1.2011.6.15.1.1.1.47
hwIpSpcAttributeRemotePort
Remote UDP port of the SPC. If the SPC's type is IPSPC, the remote UDP port must be configured.
Integer32r/w
Constraints:
range: 0-65535
.1.3.6.1.4.1.2011.6.15.1.1.1.48
hwIpSpcAttributeVoiceCode
Voice codec type of the SPC.
Options:
1. acG711Malaw(1) -G.711A
2. acG711Mulaw(2) -G.711U
3. acG723Low(3) -G.723low
4. acG723High(4) -G.723high
5. acG729(5) -G.729
6. clearMode(6) -clear mode
7. g72616k(7) -…
Enumerationr/w
Enumerated Values:
-1invalid
1acG711Malaw
2acG711Mulaw
3acG723Low
4acG723High
5acG729
6clearMode
7g72616k
8g72624k
9g72632k
10g72640k
11g722
.1.3.6.1.4.1.2011.6.15.1.1.1.49
hwIpSpcAttributeEce
The switch of EC.
Options:
1. disable(1) -disable EC
2. enable(2) -enable EC
3. invalid(-1) -invalid value
Enumerationr/w
Enumerated Values:
-1invalid
1disable
2enable
.1.3.6.1.4.1.2011.6.15.1.1.1.50
hwIpSpcAttributeSce
The switch of SC.
Options:
1. disable(1) -disable SC
2. enable(2) -enable SC
3. invalid(-1) -invalid value
Enumerationr/w
Enumerated Values:
-1invalid
1disable
2enable
.1.3.6.1.4.1.2011.6.15.1.1.1.51
hwIpSpcAttributeRtpInterval
RTP sampling time.
Options:
1. five(1) -5 ms
2. ten(2) -10 ms
3. twenty(3) -20 ms
4. thirty(4) -30 ms
5. invalid(255) -invalid value
Unit: millisecond
Enumerationr/w
Enumerated Values:
1five
2ten
3twenty
4thirty
255invalid
.1.3.6.1.4.1.2011.6.15.1.1.1.52
hwIpSpcAttributePlc
The switch of PLC.
Options:
1. enable(1) -enable PLC
2. disable(2) -disable PLC
3. invalid(255) -invalid value
Enumerationr/w
Enumerated Values:
1enable
2disable
255invalid
.1.3.6.1.4.1.2011.6.15.1.1.1.53
hwIpSpcAttributeRfc2198
The switch of 2198.
Options:
1. enable(1) -enable RFC2198 redundancy
2. disable(2) -disable RFC2198 redundancy
3. invalid(255) -invalid value
Enumerationr/w
Enumerated Values:
1enable
2disable
255invalid
.1.3.6.1.4.1.2011.6.15.1.1.1.54
hwIpSpcAttributeJbMode
Jitterbuffer mode.
Options:
1. adapt(1) -adapt
2. fixed(2) -fixed
3. invalid(255) -invalid value
Enumerationr/w
Enumerated Values:
1adapt
2fixed
255invalid
.1.3.6.1.4.1.2011.6.15.1.1.1.55
hwIpSpcAttributeWorkMode
DSP work mode.
Options:
1. voice(1) -voice
2. fax(2) -fax
3. modem(3) -modem
4. invalid(255) -invalid value
Enumerationr/w
Enumerated Values:
1voice
2fax
3modem
255invalid
.1.3.6.1.4.1.2011.6.15.1.1.1.56
hwIpSpcAttributeStreamMode
Connect mode.
Options:
1. sendReceive(1) -send and receive
2. sendOnly(2) -send only
3. receiveOnly(3) -receive only
4. invalid(255) -invalid value
Enumerationr/w
Enumerated Values:
1sendReceive
2sendOnly
3receiveOnly
255invalid
.1.3.6.1.4.1.2011.6.15.1.1.1.57
hwRemotePortStepNum
The remote-port step. If the value is 65535, the ANSPC does not use the remote port step number attribute.
Integer32r/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.2011.6.15.1.1.1.58
hwLinksetNo
IUA link set number.
In the case of the U interface transparent, this parameter must be configured.
If the value is -1, it indicates that the SPC does not use the IUA link set number.
Integer32r/w
Constraints:
range: -1-31
.1.3.6.1.4.1.2011.6.15.1.1.1.59
hwInterfaceID
IUA interface ID.
In the case of the U interface transparent, this parameter must be configured.
If the value is -1, it indicates that the SPC does not use the IUA interface ID.
Integer32r/w
Constraints:
range: -1-65535
.1.3.6.1.4.1.2011.6.15.1.1.1.60
hwConfGroup
Conference Group ID.
This leaf is not used on the OLT.
Integer32r/w
Constraints:
range: 0-15
.1.3.6.1.4.1.2011.6.15.1.1.1.61
hwB1DspInfo
Information of B1 DSP in conference service or BRA IP service.
It contains 32 characters and it is in the format of FrameID/SlotID/CardID/ChipID/CHNID.
This leaf is not used on the OLT.
OctetString
Constraints:
range: 9-32
.1.3.6.1.4.1.2011.6.15.1.1.1.62
hwB2DspInfo
Information of B2 DSP in BRA ip service.
It contains 32 characters and it is in the format of FrameID/SlotID/CardID/ChipID/CHNID
This leaf is not used on OLT.
OctetString
Constraints:
range: 9-32
.1.3.6.1.4.1.2011.6.15.1.1.1.63
hwSignalType
Signal type of IP SPC.
Options:
1. 1 - normal
2. 2 - 2833
This leaf is only used on the UA5000.
Integer32r/w
Constraints:
range: 1-2
.1.3.6.1.4.1.2011.6.15.1.1.1.64
hwSpcInitialRingType
IP SPC initial ring type.
Enumeration type:
1-Null, 2-Normal ring (FSK) 1:4, 3-Special ring (FSK) 1:2, 4-Special ring (FSK) 0.4:0.2:0.4:4, 5-Special ring (FSK) 1.2:2, 6-HK ring (FSK) 1:3, 7-HK CNTRX (FSK) 0.4:0.2:0.4:0…
Integer32r/w
Constraints:
range: 1-27
.1.3.6.1.4.1.2011.6.15.1.1.1.65
hwSpcCadenceRingType
IP SPC cadence ring type.
Enumerated types:
1-Null, 2-Normal ring 1:4, 3-Special ring 1:2, 4-Special ring 0.4:0.2:0.4:4, 5-Long ring, 6-Special ring 1.2:2, 7-HK ring 1:3, 8-HK CNTRX 0.4:0.2:0.4:0.2:0.4:3.0,
9-HK DN-A 0…
Integer32r/w
Constraints:
range: 1-30
.1.3.6.1.4.1.2011.6.15.1.1.1.66
hwSpc2833Payload
IP SPC 2833 payload type.
This leaf is only used on the UA5000.
Integer32r/w
Constraints:
range: 96-127
.1.3.6.1.4.1.2011.6.15.1.1.1.67
.1.3.6.1.4.1.2011.6.15.1.4 · 1 row entry · 5 columns
You can add, delete, modify or query SPC protect group using hwSpcProtectGroupTable.
The index of this table is hwSpcProtectGroupID.
hwSpcProtectGroupEntry entry .1.3.6.1.4.1.2011.6.15.1.4.1
You can add, delete, modify or query SPC protect group using hwSpcProtectGroupTable.
The index of this entry is hwSpcProtectGroupID.
Indexes
hwSpcProtectGroupID
Column Syntax OID
hwSpcProtectGroupID
Index of the SPC E1 protect group.
Range: 0-2 for UA products.
Integer32
Constraints:
range: 0-2
.1.3.6.1.4.1.2011.6.15.1.4.1.1
hwSpcMainPortFrameID
Frame ID of SPC E1 protect service link. It must have been described in HUAWEI-DIVICE-MIB.
Integer32r/w
Constraints:
range: 0-97
.1.3.6.1.4.1.2011.6.15.1.4.1.2
hwSpcMainPortSlotID
Slot ID of SPC E1 protect service link. It must have been described in HUAWEI-DIVICE-MIB.
Integer32r/w
Constraints:
range: 0-35
.1.3.6.1.4.1.2011.6.15.1.4.1.3
hwSpcMainPortPortID
Port ID of SPC E1 protect service link. It must have been described in HUAWEI-DIVICE-MIB.
Integer32r/w
Constraints:
range: 0-63
.1.3.6.1.4.1.2011.6.15.1.4.1.4
hwProtectGroupRowStatus
Row status. It supports only CreateAndGo(4) and Destroy(6).
SNMPv2-TCRowStatusr/w
Textual Convention: SNMPv2-TCRowStatus Enumeration
Type Values:
1active
2notInService
3notReady
4createAndGo
5createAndWait
6destroy
.1.3.6.1.4.1.2011.6.15.1.4.1.5
.1.3.6.1.4.1.2011.6.15.1.5 · 1 row entry · 8 columns
You can add, delete, modify or query SPC protect link using hwSpcProtectTable.
The index of this table is hwSpcProtectID.
hwSpcProtectEntry entry .1.3.6.1.4.1.2011.6.15.1.5.1
You can add, delete, modify or query SPC protect link using hwSpcProtectTable.
The index of this entry is hwSpcProtectID.
Indexes
hwSpcProtectID
Column Syntax OID
hwSpcProtectID
Index of the SPC E1 protect link.
Range: 0-8 for UA products.
Integer32
Constraints:
range: 0-8
.1.3.6.1.4.1.2011.6.15.1.5.1.1
hwSpcProtectGroupId
Index of the SPC E1 protect group.
Integer32
Constraints:
range: 0-2
.1.3.6.1.4.1.2011.6.15.1.5.1.2
hwSpcProtectPortFrameID
Frame ID of SPC E1 protect link. It must have been described in HUAWEI-DIVICE-MIB.
Integer32r/w
Constraints:
range: 0-97
.1.3.6.1.4.1.2011.6.15.1.5.1.3
hwSpcProtectPortSlotID
Slot ID of SPC E1 protect link. It must have been described in HUAWEI-DIVICE-MIB.
Integer32r/w
Constraints:
range: 0-35
.1.3.6.1.4.1.2011.6.15.1.5.1.4
hwSpcProtectPortPortID
Port ID of SPC E1 protect link. It must have been described in HUAWEI-DIVICE-MIB.
Integer32r/w
Constraints:
range: 0-63
.1.3.6.1.4.1.2011.6.15.1.5.1.5
hwSpcProtectPriority
Priority of SPC E1 protect link. 1: cat1(1), 2: cat1(2), 3: cat1(3).
Integer32r/w
Constraints:
range: 1-3
.1.3.6.1.4.1.2011.6.15.1.5.1.6
hwSpcProtectUsedFlag
State of the SPC E1 protect link.
Integer32
Constraints:
range: 1-2
.1.3.6.1.4.1.2011.6.15.1.5.1.7
hwProtectLinkRowStatus
Row status. It supports only CreateAndGo(4) and Destroy(6).
SNMPv2-TCRowStatusr/w
Textual Convention: SNMPv2-TCRowStatus Enumeration
Type Values:
1active
2notInService
3notReady
4createAndGo
5createAndWait
6destroy
.1.3.6.1.4.1.2011.6.15.1.5.1.8
.1.3.6.1.4.1.2011.6.15.1.6 · 1 row entry · 13 columns
You can add, delete, modify or query sub-rate switch using hwSubRateSwitchTable.
The index of this table is hwSubRateSwitchID.
hwSubRateSwitchEntry entry .1.3.6.1.4.1.2011.6.15.1.6.1
You can add, delete, modify or query sub-rate switch using hwSubRateSwitchTable.
The index of this entry is hwSubRateSwitchID.
Indexes
hwSubRateSwitchID
Column Syntax OID
hwSubRateSwitchID
Index of the sub-rate switch
Integer32
Constraints:
range: 0-1023
.1.3.6.1.4.1.2011.6.15.1.6.1.1
hwSubRateSwitchStartFrameID
Frame ID of sub-rate switch start point. It must have been described in HUAWEI-DIVICE-MIB.
Integer32r/w
Constraints:
range: 0-97
.1.3.6.1.4.1.2011.6.15.1.6.1.2
hwSubRateSwitchStartSlotID
Slot ID of sub-rate switch start point. It must have been described in HUAWEI-DIVICE-MIB.
Integer32r/w
Constraints:
range: 0-35
.1.3.6.1.4.1.2011.6.15.1.6.1.3
hwSubRateSwitchStartPortID
Port ID of sub-rate switch start point. It must have been described in HUAWEI-DIVICE-MIB.
Integer32r/w
Constraints:
range: 0-31
.1.3.6.1.4.1.2011.6.15.1.6.1.4
hwSubRateSwitchStartChannelID
Channel index of sub-rate switch start point
Integer32r/w
Constraints:
range: 0-31
.1.3.6.1.4.1.2011.6.15.1.6.1.5
hwSubRateSwitchStartSubChannelID
sub-rate channel index of sub-rate switch start point
Integer32r/w
Constraints:
range: 0-19
.1.3.6.1.4.1.2011.6.15.1.6.1.6
hwSubRateSwitchEndFrameID
Frame ID of sub-rate switch end point. It must have been described in HUAWEI-DIVICE-MIB.
Integer32r/w
Constraints:
range: 0-97
.1.3.6.1.4.1.2011.6.15.1.6.1.7
hwSubRateSwitchEndSlotID
Slot ID of sub-rate switch end point. It must have been described in HUAWEI-DIVICE-MIB.
Integer32r/w
Constraints:
range: 0-35
.1.3.6.1.4.1.2011.6.15.1.6.1.8
hwSubRateSwitchEndPortID
Port ID of sub-rate switch end point. It must have been described in HUAWEI-DIVICE-MIB.
Integer32r/w
Constraints:
range: 0-31
.1.3.6.1.4.1.2011.6.15.1.6.1.9
hwSubRateSwitchEndChannelID
Channel index of sub-rate switch end point.
Integer32r/w
Constraints:
range: 0-31
.1.3.6.1.4.1.2011.6.15.1.6.1.10
hwSubRateSwitchEndSubChannelID
sub-rate channel index of sub-rate switch end point.
Integer32r/w
Constraints:
range: 0-19
.1.3.6.1.4.1.2011.6.15.1.6.1.11
hwSubRateSwitchState
sub-rate switch state.
Options:
1. fault(1) -fault
2. normal(2) -normal
Enumeration
Enumerated Values:
1fault
2normal
.1.3.6.1.4.1.2011.6.15.1.6.1.12
hwSubRateSwitchRowStatus
Row status. It supports only CreateAndGo(4) and Destroy(6).
SNMPv2-TCRowStatusr/w
Textual Convention: SNMPv2-TCRowStatus Enumeration
Type Values:
1active
2notInService
3notReady
4createAndGo
5createAndWait
6destroy
.1.3.6.1.4.1.2011.6.15.1.6.1.13