hwSignalType
HUAWEI-SPC-MIB ·
.1.3.6.1.4.1.2011.6.15.1.1.1.64
Object
column
r/w
Integer32
Signal type of IP SPC. Options: 1. 1 - normal 2. 2 - 2833 This leaf is only used on the UA5000.
Context
- MIB
- HUAWEI-SPC-MIB
- OID
.1.3.6.1.4.1.2011.6.15.1.1.1.64- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- hwSpcMngtEntry
- Table
- hwSpcMngtTable
- Siblings
- 66
Syntax
Integer32
Values & Constraints
Object Constraints
range: 1-2
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| hwSpcNo Index of the SPC
Range: 0-2047 for MD products and 0-511 for MA products | column | Integer32 | .1.3.6.1.4.1.2011.6.15.1.1.1.1 |
| hwChannelNum Total channels occupied by the SPC. | column | Integer32 | .1.3.6.1.4.1.2011.6.15.1.1.1.10 |
| hwApptype Applied type of SPC.
Options:
1. normal(1) -normal application
2. hotline(2) -hotline application
3. mChannelTransparent(3) -M channel transparent
4. pBX-extention(4) -Z interface… | column | Enumeration | .1.3.6.1.4.1.2011.6.15.1.1.1.11 |
| hwSpctype Configuration type of SPC.
Options:
1. anSpc(1) -Internal SPC
2. v5Spc(2) -V5 SPC
3. v5Preconnect(3) -V5 pre-connection SPC
4. private(4) -leased line SPC
5. ipspc(5) -IP SPC
6. c… | column | Enumeration | .1.3.6.1.4.1.2011.6.15.1.1.1.12 |
| hwStartPortSubType Sub type of SPC's start port. If the SPC is used for PHS, the type must be set to mnt or mlt.
Options:
1. noSubType(255) -no sub type
2. mnt(1) -mnt
3. mlt(2) -mlt | column | Enumeration | .1.3.6.1.4.1.2011.6.15.1.1.1.13 |
| hwEndPortSubType Sub type of SPC's end port.
This node is not used on the OLT.
Options:
1. noSubType(255) -no sub type
2. mnt(1) -mnt
3. mlt(2) -mlt | column | Enumeration | .1.3.6.1.4.1.2011.6.15.1.1.1.14 |
| hwPathProtect Enable path protection. This leaf is not used on the OLT.
Options:
1. yes(1) -YES
2. no(2) -NO | column | Enumeration | .1.3.6.1.4.1.2011.6.15.1.1.1.15 |
| hwSPCName Name of SPC. It contains 31 characters.
- means it is not configured. | column | OctetString | .1.3.6.1.4.1.2011.6.15.1.1.1.16 |
| hwSpcState SPC state.
Options:
1. idle(1) -idle
2. normal(2) -normal
3. error(3) -error
4. errorChecking(4) -error checking
5. occupying(5) -occupying
6. checking(6) -checking
7. released(7)… | column | Enumeration | .1.3.6.1.4.1.2011.6.15.1.1.1.17 |
| hwFailCause Fault reason of SPC.
Options:
1. startBusy(1) -the start port is busy
2. endBusy(2) - the end port is busy
3. startFault(3) - the start port is fault
4. endFault(4) - the end port… | column | Enumeration | .1.3.6.1.4.1.2011.6.15.1.1.1.18 |
| hwOprType Operate type of SPC. It can be set to disconnect or connect.
Options:
1. noOperation(1) -no operation
2. connect(2) -connect
3. disconnect(3) -disconnect | column | Enumeration | .1.3.6.1.4.1.2011.6.15.1.1.1.19 |
| hwStartFrameID Frame ID of SPC's start point. It must have been described in HUAWEI-DIVICE-MIB. | column | Integer32 | .1.3.6.1.4.1.2011.6.15.1.1.1.2 |
| hwRowStatus Row status. It supports only CreateAndGo(4) and Destroy(6). | column | SNMPv2-TCRowStatus | .1.3.6.1.4.1.2011.6.15.1.1.1.20 |
| hwStartCESFrame Start CES shelf.
If the value is 255, it indicates that the SPC does not use this path.
This leaf is not used on the OLT. | column | Integer32 | .1.3.6.1.4.1.2011.6.15.1.1.1.21 |
| hwStartCESSlot CES slot.
If the value is 255, it indicates that the SPC does not use this path.
This leaf is not used on the OLT. | column | Integer32 | .1.3.6.1.4.1.2011.6.15.1.1.1.22 |
| hwStartCESPort Start CES port.
If the value is 255, it indicates that the SPC does not use this path.
This leaf is not used on the OLT. | column | Integer32 | .1.3.6.1.4.1.2011.6.15.1.1.1.23 |
| hwStartUpPv8Frame Start upstream PV8 shelf.
If the value is 255, it indicates that the SPC does not use this path.
This leaf is not used on the OLT. | column | Integer32 | .1.3.6.1.4.1.2011.6.15.1.1.1.24 |
| hwStartUpPv8Slot Start upstream PV8 slot.
If the value is 255, it indicates that the SPC does not use this path.
This leaf is not used on the OLT. | column | Integer32 | .1.3.6.1.4.1.2011.6.15.1.1.1.25 |
| hwStartUpPv8Port Start upstream PV8 port.
If the value is 255, it indicates that the SPC does not use this path.
This leaf is not used on the OLT. | column | Integer32 | .1.3.6.1.4.1.2011.6.15.1.1.1.26 |
| hwStartDownPv8Frame Start downstream PV8 shelf.
If the value is 255, it indicates that the SPC does not use this path.
This leaf is not used on the OLT. | column | Integer32 | .1.3.6.1.4.1.2011.6.15.1.1.1.27 |
| hwStartDownPv8Slot Start downstream PV8 slot.
If the value is 255, it indicates that the SPC does not use this path.
This leaf is not used on the OLT. | column | Integer32 | .1.3.6.1.4.1.2011.6.15.1.1.1.28 |
| hwStartDownPv8Port Start downstream PV8 port.
If the value is 255, it indicates that the SPC does not use this path.
This leaf is not used on the OLT. | column | Integer32 | .1.3.6.1.4.1.2011.6.15.1.1.1.29 |
| hwStartSlotID Slot ID of SPC's start point. It must have been described in HUAWEI-DIVICE-MIB. | column | Integer32 | .1.3.6.1.4.1.2011.6.15.1.1.1.3 |
| hwStartRspFrame Start downstream RSP shelf.
If the value is 255, it indicates that the SPC does not use this path.
This leaf is not used on the OLT. | column | Integer32 | .1.3.6.1.4.1.2011.6.15.1.1.1.30 |
| hwStartRspSlot Start downstream RSP slot.
If the value is 255, it indicates that the SPC does not use this path.
This leaf is not used on the OLT. | column | Integer32 | .1.3.6.1.4.1.2011.6.15.1.1.1.31 |
| hwStartRspPort Start downstream RSP port.
If the value is 255, it indicates that the SPC does not use this path.
This leaf is not used on the OLT. | column | Integer32 | .1.3.6.1.4.1.2011.6.15.1.1.1.32 |
| hwEndtCESFrame End downstream CES shelf.
If the value is 255, it indicates that the SPC does not use this path.
This leaf is not used on the OLT. | column | Integer32 | .1.3.6.1.4.1.2011.6.15.1.1.1.33 |
| hwEndCESSlot End downstream CES slot.
If the value is 255, it indicates that the SPC does not use this path.
This leaf is not used on the OLT. | column | Integer32 | .1.3.6.1.4.1.2011.6.15.1.1.1.34 |
| hwEndCESPort End CES port.
If the value is 255, it indicates that the SPC does not use this path.
This leaf is not used on the OLT. | column | Integer32 | .1.3.6.1.4.1.2011.6.15.1.1.1.35 |
| hwEndUpPv8Frame End upstream PV8 shelf.
If the value is 255, it indicates that the SPC does not use this path.
This leaf is not used on the OLT. | column | Integer32 | .1.3.6.1.4.1.2011.6.15.1.1.1.36 |
| hwEndUpPv8Slot End upstream PV8 slot.
If the value is 255, it indicates that the SPC does not use this path.
This leaf is not used on the OLT. | column | Integer32 | .1.3.6.1.4.1.2011.6.15.1.1.1.37 |
| hwEndUpPv8Port End upstream PV8 port.
If the value is 255, it indicates that the SPC does not use this path.
This leaf is not used on the OLT. | column | Integer32 | .1.3.6.1.4.1.2011.6.15.1.1.1.38 |
| hwEndDownPv8Frame End downstream PV8 shelf.
If the value is 255, it indicates that the SPC does not use this path.
This leaf is not used on the OLT. | column | Integer32 | .1.3.6.1.4.1.2011.6.15.1.1.1.39 |
| hwStartPort Port ID of SPC's start point. It must have been described in HUAWEI-DIVICE-MIB. | column | Integer32 | .1.3.6.1.4.1.2011.6.15.1.1.1.4 |
| hwEndDownPv8Slot End downstream PV8 slot.
If the value is 255, it indicates that the SPC does not use this path.
This leaf is not used on the OLT. | column | Integer32 | .1.3.6.1.4.1.2011.6.15.1.1.1.40 |
| hwEndDownPv8Port End downstream PV8 port.
If the value is 255, it indicates that the SPC does not use this path.
This leaf is not used on the OLT. | column | Integer32 | .1.3.6.1.4.1.2011.6.15.1.1.1.41 |
| hwEndRspFrame End RSP shelf.
If the value is 255, it indicates that the SPC does not use this path.
This leaf is not used on the OLT. | column | Integer32 | .1.3.6.1.4.1.2011.6.15.1.1.1.42 |
| hwEndRspSlot End RSP slot.
If the value is 255, it indicates that the SPC does not use this path.
This leaf is not used on the OLT. | column | Integer32 | .1.3.6.1.4.1.2011.6.15.1.1.1.43 |
| hwEndRspPort End RSP port.
If the value is 255, it indicates that the SPC does not use this path.
This leaf is not used on the OLT. | column | Integer32 | .1.3.6.1.4.1.2011.6.15.1.1.1.44 |
| hwIpSpcAttributeLocalIPAddr Local IP address of the SPC. If the SPC's type is IPSPC, the local IP address must be configured. | column | SNMPv2-SMIIpAddress | .1.3.6.1.4.1.2011.6.15.1.1.1.45 |
| hwIpSpcAttributeLocalPort Local UDP port of the SPC. If the SPC's type is IPSPC, the local UDP port must be configured. | column | Integer32 | .1.3.6.1.4.1.2011.6.15.1.1.1.46 |
| hwIpSpcAttributeRemoteIPAddr Remote IP address of the SPC. If the SPC's type is IPSPC, the remote IP address mustd be configured. | column | SNMPv2-SMIIpAddress | .1.3.6.1.4.1.2011.6.15.1.1.1.47 |
| hwIpSpcAttributeRemotePort Remote UDP port of the SPC. If the SPC's type is IPSPC, the remote UDP port must be configured. | column | Integer32 | .1.3.6.1.4.1.2011.6.15.1.1.1.48 |
| hwIpSpcAttributeVoiceCode Voice codec type of the SPC.
Options:
1. acG711Malaw(1) -G.711A
2. acG711Mulaw(2) -G.711U
3. acG723Low(3) -G.723low
4. acG723High(4) -G.723high
5. acG729(5) -G.729
6. … | column | Enumeration | .1.3.6.1.4.1.2011.6.15.1.1.1.49 |
| hwStartBsn Channel index of SPC's start point | column | Integer32 | .1.3.6.1.4.1.2011.6.15.1.1.1.5 |
| hwIpSpcAttributeEce The switch of EC.
Options:
1. disable(1) -disable EC
2. enable(2) -enable EC
3. invalid(-1) -invalid value | column | Enumeration | .1.3.6.1.4.1.2011.6.15.1.1.1.50 |
| hwIpSpcAttributeSce The switch of SC.
Options:
1. disable(1) -disable SC
2. enable(2) -enable SC
3. invalid(-1) -invalid value | column | Enumeration | .1.3.6.1.4.1.2011.6.15.1.1.1.51 |
| hwIpSpcAttributeRtpInterval RTP sampling time.
Options:
1. five(1) -5 ms
2. ten(2) -10 ms
3. twenty(3) -20 ms
4. thirty(4) -30 ms
5. invalid(255) -invalid value
Unit: millisecond | column | Enumeration | .1.3.6.1.4.1.2011.6.15.1.1.1.52 |
| hwIpSpcAttributePlc The switch of PLC.
Options:
1. enable(1) -enable PLC
2. disable(2) -disable PLC
3. invalid(255) -invalid value | column | Enumeration | .1.3.6.1.4.1.2011.6.15.1.1.1.53 |
| hwIpSpcAttributeRfc2198 The switch of 2198.
Options:
1. enable(1) -enable RFC2198 redundancy
2. disable(2) -disable RFC2198 redundancy
3. invalid(255) -invalid value | column | Enumeration | .1.3.6.1.4.1.2011.6.15.1.1.1.54 |
| hwIpSpcAttributeJbMode Jitterbuffer mode.
Options:
1. adapt(1) -adapt
2. fixed(2) -fixed
3. invalid(255) -invalid value | column | Enumeration | .1.3.6.1.4.1.2011.6.15.1.1.1.55 |
| hwIpSpcAttributeWorkMode DSP work mode.
Options:
1. voice(1) -voice
2. fax(2) -fax
3. modem(3) -modem
4. invalid(255) -invalid value | column | Enumeration | .1.3.6.1.4.1.2011.6.15.1.1.1.56 |
| hwIpSpcAttributeStreamMode Connect mode.
Options:
1. sendReceive(1) -send and receive
2. sendOnly(2) -send only
3. receiveOnly(3) -receive only
4. invalid(255) -invalid value | column | Enumeration | .1.3.6.1.4.1.2011.6.15.1.1.1.57 |
| hwRemotePortStepNum The remote-port step. If the value is 65535, the ANSPC does not use the remote port step number attribute. | column | Integer32 | .1.3.6.1.4.1.2011.6.15.1.1.1.58 |
| hwLinksetNo IUA link set number.
In the case of the U interface transparent, this parameter must be configured.
If the value is -1, it indicates that the SPC does not use the IUA link set num… | column | Integer32 | .1.3.6.1.4.1.2011.6.15.1.1.1.59 |
| hwEndFrameID Shelf ID of ANSPC's end point. It must have been described in HUAWEI-DIVICE-MIB.
The value 255 indicates that this parameter is not used. | column | Integer32 | .1.3.6.1.4.1.2011.6.15.1.1.1.6 |
| hwInterfaceID IUA interface ID.
In the case of the U interface transparent, this parameter must be configured.
If the value is -1, it indicates that the SPC does not use the IUA interface ID. | column | Integer32 | .1.3.6.1.4.1.2011.6.15.1.1.1.60 |
| hwConfGroup Conference Group ID.
This leaf is not used on the OLT. | column | Integer32 | .1.3.6.1.4.1.2011.6.15.1.1.1.61 |
| hwB1DspInfo Information of B1 DSP in conference service or BRA IP service.
It contains 32 characters and it is in the format of FrameID/SlotID/CardID/ChipID/CHNID.
This leaf is not used on th… | column | OctetString | .1.3.6.1.4.1.2011.6.15.1.1.1.62 |
| hwB2DspInfo Information of B2 DSP in BRA ip service.
It contains 32 characters and it is in the format of FrameID/SlotID/CardID/ChipID/CHNID
This leaf is not used on OLT. | column | OctetString | .1.3.6.1.4.1.2011.6.15.1.1.1.63 |
| hwSpcInitialRingType IP SPC initial ring type.
Enumeration type:
1-Null, 2-Normal ring (FSK) 1:4, 3-Special ring (FSK) 1:2, 4-Special ring (FSK) 0.4:0.2:0.4:4, 5-Special ring (FSK) 1.2:2, 6-HK ring (… | column | Integer32 | .1.3.6.1.4.1.2011.6.15.1.1.1.65 |
| hwSpcCadenceRingType IP SPC cadence ring type.
Enumerated types:
1-Null, 2-Normal ring 1:4, 3-Special ring 1:2, 4-Special ring 0.4:0.2:0.4:4, 5-Long ring, 6-Special ring 1.2:2, 7-HK ring 1:3, 8-HK CN… | column | Integer32 | .1.3.6.1.4.1.2011.6.15.1.1.1.66 |
| hwSpc2833Payload IP SPC 2833 payload type.
This leaf is only used on the UA5000. | column | Integer32 | .1.3.6.1.4.1.2011.6.15.1.1.1.67 |
| hwEndSlotID Slot ID of ANSPC's end point. It must have been described in HUAWEI-DIVICE-MIB.
The value 255 indicates that this parameter is not used. | column | Integer32 | .1.3.6.1.4.1.2011.6.15.1.1.1.7 |
| hwEndPort Port ID of ANSPC's end point. It must have been described in HUAWEI-DIVICE-MIB.
The value 255 indicates that this parameter is not used. | column | Integer32 | .1.3.6.1.4.1.2011.6.15.1.1.1.8 |
| hwEndBsn Channel index of SPC's end point.
The value 255 indicates that this parameter is not used. | column | Integer32 | .1.3.6.1.4.1.2011.6.15.1.1.1.9 |