.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1 · 1 row entry · 65 columns
A table of objects that display transceiver
characteristics.
hpicfXcvrInfoEntry entry .1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1
A set of objects that displays information of
a transceiver.
Indexes
IF-MIBifIndex
Column Syntax OID
hpicfXcvrPortIndex
The interface number for this entry.
Integer32
Constraints:
range: 1-2147483647
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.1
hpicfXcvrPortDesc
A textual description of the interface.
OctetString
Constraints:
range: 1-8
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.2
hpicfXcvrModel
A textual description of the transceiver
model number.
OctetString
Constraints:
range: 1-32
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.3
hpicfXcvrSerial
A textual description of the transceiver
serial number.
OctetString
Constraints:
range: 1-32
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.4
hpicfXcvrType
A textual description of the transceiver type.
OctetString
Constraints:
range: 1-32
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.5
hpicfXcvrConnectorType
A textual description of the transceiver
connector type.
OctetString
Constraints:
range: 1-64
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.6
hpicfXcvrWavelength
A textual description of the central optical
wavelength.

n/a will be reported for copper transceivers.
OctetString
Constraints:
range: 1-96
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.7
hpicfXcvrTxDist
A textual description of the link length
supported by the transceiver.
OctetString
Constraints:
range: 1-64
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.8
hpicfXcvrDiagnostics
This object indicates transceiver diagnostic support.
May be one of Virtual Cable Test (VCT), Diagnostic
Optical Monitoring (DOM), other or none.
Enumeration
Enumerated Values:
0none
1dom
2vct
3other
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.9
hpicfXcvrDiagnosticsUpdate
This object will cause specific actions
depending on the diagnostic support of the
transceiver.

Transceiver Diagnostic support:

None : No action taken.
DOM : Will update diagnostic infor…
SNMPv2-TCTruthValuer/w
Textual Convention: SNMPv2-TCTruthValue Enumeration
Type Values:
1true
2false
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.10
hpicfXcvrTemp
This is transceiver internal temperature
in thousandths of degrees Celsius.

As an example: 49120 is 49.120 degrees Celsius.

The value of this object is valid when the value of
the hpicfXcv…
thousandths of degrees CelsiusSNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.11
hpicfXcvrVoltage
This is transceiver supply voltage
in hundreds of microvolts.

As an example: 32928 is 3.2928 volts.

Will be zero if the transceiver does not report
this object.

The value of …
hundreds of microvoltsUnsigned32
Constraints:
range: 0-65535
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.12
hpicfXcvrBias
This is Tx bias current in microamps.

The value of this object is valid when the value of
the hpicfXcvrDiagnostics object is DOM.
microampsUnsigned32
Constraints:
range: 0-65535
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.13
hpicfXcvrTxPower
This is transmit output power
in thousandths of dBm.

As an example: -5840 is -5.840dBm.

-in dBm (0 microwatts) will be reported as -99999999.

The value of this object is vali…
thousandths of dBmSNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.14
hpicfXcvrRxPower
This is received optical power
in thousandths of dBm.

As an example: -5840 is -5.840dBm.

-in dBm (0 microwatts) will be reported as -99999999.

The value of this object is val…
thousandths of dBmSNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.15
hpicfXcvrAlarms
Bitmask indicating transceiver alarms,
Rx power low warning(0)
Rx power high warning(1)
Tx power low warning(2)
Tx power high warning(3)
Tx bias low warning(4)
Tx bias high warning(5)
Vcc low warning(6)
Vcc high warning…
Bits
Enumerated Values:
0rxPowerLowWarning
1rxPowerHighWarning
2txPowerLowWarning
3txPowerHighWarning
4txBiasLowWarning
5txBiasHighWarning
6vccLowWarning
7vccHighWarning
8tempLowWarning
9tempHighWarning
10rxPowerLowAlarm
11rxPowerHighAlarm
12txPowerLowAlarm
13txPowerHighAlarm
14txBiasLowAlarm
15txBiasHighAlarm
16vccLowAlarm
17vccHighAlarm
18tempLowAlarm
19tempHighAlarm
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.16
hpicfXcvrErrors
Bitmask indicating transceiver errors.
Transceiver information I/O error(0)
Transceiver information checksum error(1)
Transceiver type and port configuration mismatch(2)
Transceiver type not supported by port hardware(3…
Bits
Enumerated Values:
0xcvrIOError
1xcvrChecksum
2xcvrTypeAndPortConfigMismatch
3xcvrTypeNotSupported
4wisLocalFault
5rcvOpticalPowerFault
6pmapmdReceiverLocalFault
7pcsReceiveLocalFault
8phyXSReceiveLocalFault
9laserBiasCurrentFault
10laserTemperatureFault
11laserOutputPowerFault
12txFault
13pmapmdTransmitterLocalFault
14pcsTransmitLocalFault
15phyXSTransmitLocalFault
16rxLossOfSignal
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.17
hpicfXcvrTempHiAlarm
Transceiver temperature high alarm
threshold limit in thousandths of degrees Celsius.

As an example: 49120 is 49.120 degrees Celsius.

The value of this object is valid when the value of
th…
thousandths of degrees CelsiusSNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.18
hpicfXcvrTempLoAlarm
Transceiver temperature low alarm
threshold limit in thousandths of degrees Celsius.

As an example: 49120 is 49.120 degrees Celsius.

The value of this object is valid when the value of
the…
thousandths of degrees CelsiusSNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.19
hpicfXcvrTempHiWarn
Transceiver temperature high warning
threshold limit in thousandths of degrees Celsius.

As an example: 49120 is 49.120 degrees Celsius.

The value of this object is valid when the value of
thousandths of degrees CelsiusSNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.20
hpicfXcvrTempLoWarn
Transceiver temperature low warning
threshold limit in thousandths of degrees Celsius.

As an example: 49120 is 49.120 degrees Celsius.

The value of this object is valid when the value of
t…
thousandths of degrees CelsiusSNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.21
hpicfXcvrVccHiAlarm
Transceiver VCC high alarm
threshold limit in hundreds of microvolts.

As an example: 32928 is 3.2928 volts.

Returns zero if not supported on the transceiver.

The value of thi…
hundreds of microvoltsUnsigned32
Constraints:
range: 0-65535
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.22
hpicfXcvrVccLoAlarm
Transceiver VCC low alarm
threshold limit in hundreds of microvolts.

As an example: 32928 is 3.2928 volts.

Returns zero if not supported on the transceiver.

The value of this…
hundreds of microvoltsUnsigned32
Constraints:
range: 0-65535
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.23
hpicfXcvrVccHiWarn
Transceiver VCC high warning
threshold limit in hundreds of microvolts.

As an example: 32928 is 3.2928 volts.

Returns zero if not supported on the transceiver.

The value of t…
hundreds of microvoltsUnsigned32
Constraints:
range: 0-65535
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.24
hpicfXcvrVccLoWarn
Transceiver VCC low warning
threshold limit in hundreds of microvolts.

As an example: 32928 is 3.2928 volts.

Returns zero if not supported on the transceiver.

The value of th…
hundreds of microvoltsUnsigned32
Constraints:
range: 0-65535
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.25
hpicfXcvrBiasHiAlarm
Transceiver bias high alarm
threshold limit in microamps.

The value of this object is valid when the value of
the hpicfXcvrDiagnostics object is DOM.
microampsUnsigned32
Constraints:
range: 0-65535
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.26
hpicfXcvrBiasLoAlarm
Transceiver bias low alarm
threshold limit in microamps.

The value of this object is valid when the value of
the hpicfXcvrDiagnostics object is DOM.
microampsUnsigned32
Constraints:
range: 0-65535
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.27
hpicfXcvrBiasHiWarn
Transceiver bias high warning
threshold limit in microamps.

The value of this object is valid when the value of
the hpicfXcvrDiagnostics object is DOM.
microampsUnsigned32
Constraints:
range: 0-65535
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.28
hpicfXcvrBiasLoWarn
Transceiver bias low warning
threshold limit in microamps.

The value of this object is valid when the value of
the hpicfXcvrDiagnostics object is DOM.
microampsUnsigned32
Constraints:
range: 0-65535
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.29
hpicfXcvrPwrOutHiAlarm
Transceiver transmit power high alarm
threshold limit in tenths of microwatts.

As an example: 10000 is 1 milliwatt.

The value of this object is valid when the value of
the hpicfXcvrDiagnos…
tenths of microwattsUnsigned32
Constraints:
range: 0-65535
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.30
hpicfXcvrPwrOutLoAlarm
Transceiver transmit power low alarm
threshold limit in tenths of microwatts.

As an example: 10000 is 1 milliwatt.

The value of this object is valid when the value of
the hpicfXcvrDiagnost…
tenths of microwattsUnsigned32
Constraints:
range: 0-65535
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.31
hpicfXcvrPwrOutHiWarn
Transceiver transmit power high warning
threshold limit in tenths of microwatts

As an example: 10000 is 1 milliwatt.

The value of this object is valid when the value of
the hpicfXcvrDiagno…
tenths of microwattsUnsigned32
Constraints:
range: 0-65535
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.32
hpicfXcvrPwrOutLoWarn
Transceiver transmit power low warning
threshold limit in tenths of microwatts.

As an example: 10000 is 1 milliwatt.

The value of this object is valid when the value of
the hpicfXcvrDiagno…
tenths of microwattsUnsigned32
Constraints:
range: 0-65535
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.33
hpicfXcvrRcvPwrHiAlarm
Transceiver receive power high alarm
threshold limit in tenths of microwatts.

As an example: 10000 is 1 milliwatt.

The value of this object is valid when the value of
the hpicfXcvrDiagnost…
tenths of microwattsUnsigned32
Constraints:
range: 0-65535
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.34
hpicfXcvrRcvPwrLoAlarm
Transceiver receive power low alarm
threshold limit in tenths of microwatts.

As an example: 10000 is 1 milliwatt.

The value of this object is valid when the value of
the hpicfXcvrDiagnosti…
tenths of microwattsUnsigned32
Constraints:
range: 0-65535
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.35
hpicfXcvrRcvPwrHiWarn
Transceiver receive power high warning
threshold limit in tenths of microwatts.

As an example: 10000 is 1 milliwatt.

The value of this object is valid when the value of
the hpicfXcvrDiagno…
tenths of microwattsUnsigned32
Constraints:
range: 0-65535
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.36
hpicfXcvrRcvPwrLoWarn
Transceiver receive power low warning
threshold limit in tenths of microwatts.

As an example: 10000 is 1 milliwatt.

The value of this object is valid when the value of
the hpicfXcvrDiagnos…
tenths of microwattsUnsigned32
Constraints:
range: 0-65535
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.37
hpicfXcvrDiagnosticsTimeStamp deprecated
********* THIS OBJECT IS DEPRECATED *********

A textual description of the diagnostics
information updated for the last time in the
transceiver.

This object has been deprecated. Its functio…
OctetString
Constraints:
range: 1-64
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.38
hpicfXcvrPhyLinkStatus
This object indicates the link status as reported
by the physical entity.

The value of this object is valid when the value of
the hpicfXcvrDiagnostics object is VCT or other.
Enumeration
Enumerated Values:
0down
1up
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.39
hpicfXcvrPhySpeed
This object indicates the speed in Mbps as reported
by the physical entity.

Will be zero if speed and duplex are unresolved.

The value of this object is valid when the value of
the hpicfX…
megabits per secondUnsigned32
Constraints:
range: 0-4294967295
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.40
hpicfXcvrPhyDuplex
This object indicates the duplex as reported by
the physical entity.

Will be unspecified if speed and duplex are unresolved.

The value of this object is valid when the value of
the hpicfXc…
Enumeration
Enumerated Values:
0half
1full
2unspecified
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.41
hpicfXcvrMdiPairACableStatus
This object indicates the diagnostics
test status on the cable pair.

Normal = No cable fault detected.
Open = Lack of continuity between ends.
Short = Short detected.
Impedance mismatch =
- Cable p…
Enumeration
Enumerated Values:
0normal
1short
2open
3failed
4impedanceMismatch
5unspecified
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.42
hpicfXcvrMdiPairACableLength
This object indicates the cable pair length in
meters as reported by cable diagnostics.

A gigabit link must be present for this object
to be non zero.

Will be zero if not available or the t…
metersUnsigned32
Constraints:
range: 0-4294967295
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.43
hpicfXcvrMdiPairADistanceToFault
This object indicates the distance in meters to
a fault in the cable pair as reported through cable
diagnostics.

Will be zero if no fault or the transceiver does not
report this object.

Ac…
metersUnsigned32
Constraints:
range: 0-4294967295
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.44
hpicfXcvrMdiPairAPolaritySwap
This object indicates if the cable pair connected
to the phy is inverted as reported through cable
diagnostics.

Will be unspecified if the this object is unavailable
or not reported.

The va…
Enumeration
Enumerated Values:
0normal
1reversed
2unspecified
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.45
hpicfXcvrMdiPairASkew
This object indicates the delay skew in nanoseconds
of this cable pair and the fastest cable pair as
reported through cable diagnostics.

Will be zero if the lowest of the pairs or if the
transceiver does…
nanosecondsUnsigned32
Constraints:
range: 0-4294967295
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.46
hpicfXcvrMdiPairBCableStatus
This object indicates the cable diagnostics
test status on the cable pair.

Normal = No cable fault detected.
Open = Lack of continuity between ends.
Short = Short detected.
Impedance mismatch =
- C…
Enumeration
Enumerated Values:
0normal
1short
2open
3failed
4impedanceMismatch
5unspecified
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.47
hpicfXcvrMdiPairBCableLength
This object indicates the cable pair length in
meters as reported by cable diagnostics.

A gigabit link must be present for this object
to be non zero.

Will be zero if not available or the …
metersUnsigned32
Constraints:
range: 0-4294967295
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.48
hpicfXcvrMdiPairBDistanceToFault
This object indicates the distance in meters to
a fault in the cable pair as reported through cable
diagnostics.

Will be zero if no fault or the transceiver does not
report this object.

Ac…
metersUnsigned32
Constraints:
range: 0-4294967295
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.49
hpicfXcvrMdiPairBPolaritySwap
This object indicates if the cable pair connected
to the phy were inverted as reported through cable
diagnostics.

Will be unspecified if the this object is unavailable
or not reported.

The …
Enumeration
Enumerated Values:
0normal
1reversed
2unspecified
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.50
hpicfXcvrMdiPairBSkew
This object indicates the delay skew in nanoseconds
of this cable pair and the fastest cable pair as
reported through cable diagnostics.

Will be zero if the lowest of the pairs or if the
transceiver does…
nanosecondsUnsigned32
Constraints:
range: 0-4294967295
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.51
hpicfXcvrMdiPairCCableStatus
This object indicates the cable diagnostics
test status on the cable pair.

Normal = No cable fault detected.
Open = Lack of continuity between ends.
Short = Short detected.
Impedance Mismatch =
- C…
Enumeration
Enumerated Values:
0normal
1short
2open
3failed
4impedanceMismatch
5unspecified
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.52
hpicfXcvrMdiPairCCableLength
This object indicates the cable length in meters
of the cable pair as reported through cable
diagnostics.

A gigabit link must be present for this object
to be non zero.

Will be zero if not…
metersUnsigned32
Constraints:
range: 0-4294967295
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.53
hpicfXcvrMdiPairCDistanceToFault
This object indicates the distance in meters to
a fault in the cable pair as reported through cable
diagnostics.

Will be zero if there is no fault or the
transceiver does not report this object.
metersUnsigned32
Constraints:
range: 0-4294967295
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.54
hpicfXcvrMdiPairCPolaritySwap
This object indicates if the cable pair connected
to the phy were inverted as reported through cable
diagnostics.

Will be unspecified if the this object is unavailable
or not reported.

The …
Enumeration
Enumerated Values:
0normal
1reversed
2unspecified
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.55
hpicfXcvrMdiPairCSkew
This object indicates the delay skew in nanoseconds
of this cable pair and the fastest cable pair as
reported through cable diagnostics.

Will be zero if the lowest of the pairs or if the
transceiver does…
nanosecondsUnsigned32
Constraints:
range: 0-4294967295
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.56
hpicfXcvrMdiPairDCableStatus
This object indicates the cable diagnostics
test status on the cable pair.

Normal = No cable fault detected.
Open = Lack of continuity between ends.
Short = Short detected.
Impedance Mismatch =
- C…
Enumeration
Enumerated Values:
0normal
1short
2open
3failed
4impedanceMismatch
5unspecified
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.57
hpicfXcvrMdiPairDCableLength
This object indicates the cable length in meters
of the cable pair as reported through cable
diagnostics.

A gigabit link must be present for this object
to be non zero.

Will be zero if not…
metersUnsigned32
Constraints:
range: 0-4294967295
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.58
hpicfXcvrMdiPairDDistanceToFault
This object indicates the distance in meters to
a fault in the cable pair as reported through cable
diagnostics.

Will be zero if no fault or the transceiver does not
report this object.

Ac…
metersUnsigned32
Constraints:
range: 0-4294967295
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.59
hpicfXcvrMdiPairDPolaritySwap
This object indicates if the cable pair connected
to the phy were inverted as reported through cable
diagnostics.

Will be unspecified if the this object is unavailable
or not reported.

The …
Enumeration
Enumerated Values:
0normal
1reversed
2unspecified
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.60
hpicfXcvrMdiPairDSkew
This object indicates the delay skew in nanoseconds
of this cable pair and the fastest cable pair as
reported through cable diagnostics.

Will be zero if the lowest of the pairs or if the
transceiver does…
nanosecondsUnsigned32
Constraints:
range: 0-4294967295
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.61
hpicfXcvrMdiPairABSwap
This object indicates the if the channels are
swapped for channels A and B as reported through
cable diagnostics.

MDI : Channel A received on MDI[1], Channel B on MDI[0]
MDIX : Channel A received on MDI[…
Enumeration
Enumerated Values:
0mdi
1mdix
2unspecified
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.62
hpicfXcvrMdiPairCDSwap
This object indicates if the channels are
swapped for channels C and D as reported through
cable diagnostics.

MDI : Channel C received on MDI[3], Channel D on MDI[2]
MDIX : Channel C received on MDI[2], …
Enumeration
Enumerated Values:
0mdi
1mdix
2unspecified
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.63
hpicfXcvrDiagnosticsTimeTicks
The value of sysUpTime of when this diagnostic
information was last updated. If this diagnostic
information was never updated, then this object
will contain a zero value.
centi-secondsSNMPv2-SMITimeTicks
Textual Convention: SNMPv2-SMITimeTicks Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.64
hpicfXcvrManufacDate
A textual description of the transceiver
Manufacturing date.
OctetString
Constraints:
range: 1-16
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.65
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.2 · 1 row entry · 6 columns
A table of objects that displays the transceiver
channel characteristics.
hpicfXcvrChannelInfoEntry entry .1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.2.1
A set of objects that displays the information of
a transceiver channel.
Indexes
IF-MIBifIndex hpicfXcvrChannel
Column Syntax OID
hpicfXcvrChannel
The channel number for this entry.
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.2.1.1
hpicfXcvrChannelTxBias
Tx bias current in microamps.

The value of this object is valid when the value of
the hpicfXcvrDiagnostics object is DOM.
microampsUnsigned32
Constraints:
range: 0-65535
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.2.1.2
hpicfXcvrChannelTxPower
This is transmit output power
in thousandths of dBm.

As an example: -5840 is -5.840dBm.

Negative infinity dBm (0 microwatts) is reported as
-99999999.

The value of this objec…
thousandths of dBmSNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.2.1.3
hpicfXcvrChannelRxPower
Received optical power in thousandths of dBm.

As an example: -5840 is -5.840dBm.

Negative infinity dBm (0 microwatts) is reported as
-99999999.

The value of this object is va…
thousandths of dBmSNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.2.1.4
hpicfXcvrChannelAlarms
Bitmask indicating transceiver channel alarms,
Rx power low warning(0)
Rx power high warning(1)
Tx power low warning(2)
Tx power high warning(3)
Tx bias low warning(4)
Tx bias high warning(5)
Rx power low alarm(6)
Rx po…
Bits
Enumerated Values:
0rxPowerLowWarning
1rxPowerHighWarning
2txPowerLowWarning
3txPowerHighWarning
4txBiasLowWarning
5txBiasHighWarning
6rxPowerLowAlarm
7rxPowerHighAlarm
8txPowerLowAlarm
9txPowerHighAlarm
10txBiasLowAlarm
11txBiasHighAlarm
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.2.1.5
hpicfXcvrChannelErrors
TX fault(0)
TX loss of signal(1)
RX loss of signal(2)

Unused(3-31)

The value of this object is valid when the value of
the hpicfXcvrDiagnostics object is DOM.
Bits
Enumerated Values:
0txFault
1txLossOfSignal
2rxLossOfSignal
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.2.1.6