hpicfXcvrMdiPairCCableStatus

HP-ICF-TRANSCEIVER-MIB · .1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.52

Object

column Enumeration
This object indicates the cable diagnostics
test status on the cable pair.
              
Normal = No cable fault detected.
Open = Lack of continuity between ends.
Short = Short detected.
Impedance Mismatch =
       - Cable pair is not connected properly or
       - Cable pair is damaged or
       - Connector is faulty.
Failed = TDR test failed on cable pair.
Unspecified : This object is unavailable or not reported. 
              
As reported through cable diagnostics.
              
The value of this object is valid when the value of 
the hpicfXcvrDiagnostics object is VCT or other.

Context

MIB
HP-ICF-TRANSCEIVER-MIB
OID
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.52
Type
column
Access
readonly
Status
current
Parent
hpicfXcvrInfoEntry
Table
hpicfXcvrInfoTable
Siblings
64

Syntax

Enumeration

Values & Constraints

Enumerated Values
0normal
1short
2open
3failed
4impedanceMismatch
5unspecified

Related Objects

Sibling Objects