HP-ICF-OPENFLOW-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
6
Rows
6
Columns
59
.1.3.6.1.4.1.11.2.14.11.5.1.89.1.4
·
1 row entry
·
33 columns
A table that is used create an OpenFlow instance. For maximum number of OpenFlow instances that can be supported, refer to hpicfOpenFLowMaxInstances MIB object.
A set of objects that are used to create an
OpenFlow instance.
OpenFlow instance.
Indexes
hpicfOpenFlowInstanceName
| Column | Syntax | OID | ||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
hpicfOpenFlowInstanceName
Unique name given to an OpenFlow instance.
The instance name 'aggregate' is special case denoting switch functioning as OpenFlow switch. The instance name allows lowercase alphanumeric characters and the special charac… |
OctetString Constraints: range: 1-32 |
.1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.1 |
||||||||||||||||||||||||||
|
hpicfOpenFlowInstanceAdminStatus
This object is used to administratively enable
or disable an OpenFlow instance. This MIB object can be set to 'enable' only when either hpicfOpenFlowInstanceListenPortCfg has been set to 'true' or atleast one contro… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.2 |
||||||||||||||||||||||||||
|
hpicfOpenFlowInstanceListenPortCfg
This object indicates if a listen-port is
configured on this OpenFlow instance. |
SNMPv2-TCTruthValuer/w Textual Convention: SNMPv2-TCTruthValue EnumerationType Values:
|
.1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.3 |
||||||||||||||||||||||||||
|
hpicfOpenFlowInstanceListenPort
Port number for the listen-port on the
OpenFlow instance. A valid port number is between 1024 and 65534 inclusive. |
INET-ADDRESS-MIBInetPortNumberr/w Textual Convention: INET-ADDRESS-MIBInetPortNumber Unsigned32Type Constraints: range: 0..65535 |
.1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.4 |
||||||||||||||||||||||||||
|
hpicfOpenFlowInstanceListenPortIsOobm
This object indicates if a listen-port is
configured for this OpenFlow instance over OOBM(Out Of Band Management) interface. This MIB object will be applicable only if there is a physical OOBM port on the device. |
SNMPv2-TCTruthValuer/w Textual Convention: SNMPv2-TCTruthValue EnumerationType Values:
|
.1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.5 |
||||||||||||||||||||||||||
|
hpicfOpenFlowInstanceMode
This object allows the user to specify the
mode of OpenFlow operation for an instance. In active mode, new flows get redirected to the OpenFlow controller. In passive mode, new flows are not sent to the OpenFlow co… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.6 |
||||||||||||||||||||||||||
|
hpicfOpenFlowInstanceFlowLocationMode
This object specifies if the flows for this
instance will be located in hardware only or in hardware and software. By default, flows will be located in hardware and software.This object is applicable only for an Op… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.7 |
||||||||||||||||||||||||||
|
hpicfOpenFlowConnectionInterruptionMode
This MIB object is used to specify the type
of fallback when the switch loses connection with the controller. In fail-secure mode, packets and messages destined to the current controller are dropped. Flows should c… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.8 |
||||||||||||||||||||||||||
|
hpicfOpenFlowInstanceHwRateLimit
This object limits the bandwidth per module
in kilobits per second, that this OpenFlow instance can utilize. This implementation supports a minimum rate limit of 0 kbps and a maximum rate limit of 10000000 kbps. |
kilobits per secondSNMPv2-SMIInteger32r/w Textual Convention: SNMPv2-SMIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.9 |
||||||||||||||||||||||||||
|
hpicfOpenFlowInstanceSwRateLimit
This object limits the number of packets per
second for each module, that this instance can send to the software path on the CPU. Increasing the software rate limit would increase CPU consumption and may impact the … |
packets per secondSNMPv2-SMIInteger32r/w Textual Convention: SNMPv2-SMIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.10 |
||||||||||||||||||||||||||
|
hpicfOpenFlowInstanceDatapathID
Datapath ID(DPID) uniquely identifies a
datapath between this instance and the controller. Its lower 48-bits are intended for switch MAC address, while the upper 16-bits are defined by the implementation. |
SNMPv2-SMICounter64 Textual Convention: SNMPv2-SMICounter64 Unsigned64Type Constraints: range: 0..18446744073709551615 |
.1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.11 |
||||||||||||||||||||||||||
|
hpicfOpenFlowInstanceNumOfHwFlows
This object indicates the number of hardware
flows in this OpenFlow instance. |
SNMPv2-SMICounter64 Textual Convention: SNMPv2-SMICounter64 Unsigned64Type Constraints: range: 0..18446744073709551615 |
.1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.12 |
||||||||||||||||||||||||||
|
hpicfOpenFlowInstanceNumOfSwFlows
This object indicates the number of software
flows in this OpenFlow instance. |
SNMPv2-SMICounter64 Textual Convention: SNMPv2-SMICounter64 Unsigned64Type Constraints: range: 0..18446744073709551615 |
.1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.13 |
||||||||||||||||||||||||||
|
hpicfOpenFlowInstanceOperStatus
This object is used to determine the
operational state of an OpenFlow instance. The reason for operational status to be down is specified by the hpicfOpenFlowInstanceOperStatusReason MIB. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.14 |
||||||||||||||||||||||||||
|
hpicfOpenFlowInstanceMaxBackOffInterval
Interval between two consecutive attempts
made by an instance to reconnect to a controller increases exponentially till it reaches the value specified by this MIB object. All subsequent attempts use this value as t… |
secondsUnsigned32r/w Constraints: range: 1-3600 |
.1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.15 |
||||||||||||||||||||||||||
|
hpicfOpenFlowInstanceRowStatus
Row status for this table.
|
SNMPv2-TCRowStatusr/w Textual Convention: SNMPv2-TCRowStatus EnumerationType Values:
|
.1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.16 |
||||||||||||||||||||||||||
|
hpicfOpenFlowInstanceProbeInterval
This MIB object specifies the interval
between two consecutive probes sent from an instance to the controller. This MIB value also determines how soon the instance will enter the connection interruption mode. If th… |
secondsUnsigned32r/w Constraints: range: 1-3600 |
.1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.17 |
||||||||||||||||||||||||||
|
hpicfOpenFlowInstanceProtoVersion
This MIB object specifies the
OpenFlow instance protocol version. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.18 |
||||||||||||||||||||||||||
|
hpicfOpenFlowInstanceProtoVersionOnly
Setting this MIB object to true will support
only the specific version mentioned by hpicfOpenFlowInstanceProtoVersion MIB and not compatible with lower versions. |
SNMPv2-TCTruthValuer/w Textual Convention: SNMPv2-TCTruthValue EnumerationType Values:
|
.1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.19 |
||||||||||||||||||||||||||
|
hpicfOpenFlowInstanceNumOfSwFlowTable
This MIB object specifies the number of
software flow tables for this OpenFlow instance. The maximum value supported is 8. This object is applicable only for an OpenFlow version 1.3 instance. |
SNMPv2-SMIUnsigned32r/w Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.20 |
||||||||||||||||||||||||||
|
hpicfOpenFlowInstanceOperStatusReason
This MIB object specifies the reason for
hpicfOpenFlowInstanceOperStatus to be down. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.21 |
||||||||||||||||||||||||||
|
hpicfOpenFlowInstanceEgressOnlyPorts
This MIB object specifies the list of egress
only ports for this OpenFlow instance. |
Q-BRIDGE-MIBPortList Textual Convention: Q-BRIDGE-MIBPortList OctetString |
.1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.22 |
||||||||||||||||||||||||||
|
hpicfOpenFlowInstanceCapabilities
This MIB object specifies the instance
capabilities exchanged with the controller. |
Bits Enumerated Values:
|
.1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.23 |
||||||||||||||||||||||||||
|
hpicfOpenFlowInstanceHwTableMissCount
This MIB object specifies the number of
packets which do not match any rules in the hardware table. This object is applicable only for an OpenFlow version 1.0 instance. |
SNMPv2-SMICounter64 Textual Convention: SNMPv2-SMICounter64 Unsigned64Type Constraints: range: 0..18446744073709551615 |
.1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.24 |
||||||||||||||||||||||||||
|
hpicfOpenFlowInstanceTableModel
This MIB object determines the table model
of an OpenFlow instance. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.25 |
||||||||||||||||||||||||||
|
hpicfOpenFlowInstanceMembers
This MIB object is used to add member VLANs to an
OpenFlow instance. |
HP-ICF-TCVidListr/w Textual Convention: HP-ICF-TCVidList OctetStringType Constraints: range: 512 |
.1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.26 |
||||||||||||||||||||||||||
|
hpicfOpenFlowInstancePipelineModel
This MIB object is used to configure the openflow
instance pipeline model. A value of 0(none) indicates no table pipeline model which is equal to standard match. A value of 1(standardMatch) enables an instance in adve… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.27 |
||||||||||||||||||||||||||
|
hpicfOpenFlowInstanceDatapathDesc
This MIB object is a user-defined description of the data
path. If not set, hpicfOpenFlowInstanceName is used. |
OctetStringr/w Constraints: range: 0-255 |
.1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.28 |
||||||||||||||||||||||||||
|
hpicfOpenFlowInstanceSourceMacGrpTable
This object is used to enable or disable the source
MAC group table in the OpenFlow pipeline. This MIB object can be set to 'enable' only on one instance. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.29 |
||||||||||||||||||||||||||
|
hpicfOpenFlowInstanceDestMacGrpTable
This object is used to enable or disable the destination
MAC group table in the OpenFlow table. This MIB object can be set to 'enable' only on one instance. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.30 |
||||||||||||||||||||||||||
|
hpicfOpenFlowInstanceMissRuleDefaultAction
This MIB object is used to configure the flow miss
action associated with the instance. A value of 0(none) indicates no flow miss action specified, which is to drop all unknown packets. A value of 1(drop) enables an in… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.31 |
||||||||||||||||||||||||||
|
hpicfOpenFlowInstanceOverrideProtocol
This MIB object is used to configure the Override
protocol associated with the instance. |
Bitsr/w Enumerated Values:
|
.1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.32 |
||||||||||||||||||||||||||
|
hpicfOpenFlowInstancePktInVlanTagging
This MIB object is used to configure the 802.1q
tagging property for a packet encapsulated inside the OpenFlow packet-in header. A value of 0 (default) indicates the default behavior which is the packet encapsulated ins… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.33 |
.1.3.6.1.4.1.11.2.14.11.5.1.89.1.5
·
1 row entry
·
1 columns
Table used to add members to OpenFlow instances. This table is deprecated and instead object hpicfOpenFlowInstanceMembers is used to configure members for an OpenFlow instance.
A set of objects that are used to add members
to an OpenFlow instance.
to an OpenFlow instance.
Indexes
hpicfOpenFlowInstanceName IF-MIBifIndex
| Column | Syntax | OID | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
hpicfOpenFlowInstanceMembershipRowStatus
deprecated
Row status for this member.
|
SNMPv2-TCRowStatusr/w Textual Convention: SNMPv2-TCRowStatus EnumerationType Values:
|
.1.3.6.1.4.1.11.2.14.11.5.1.89.1.5.1.2 |
.1.3.6.1.4.1.11.2.14.11.5.1.89.1.6
·
1 row entry
·
8 columns
Table used to configure controllers. For maximum number of OpenFlow controllers that can be supported, refer to hpicfOpenFlowMaxControllers MIB object.
A set of objects that are used to configure
OpenFlow Controllers.
OpenFlow Controllers.
Indexes
hpicfOpenFlowControllerID
| Column | Syntax | OID | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
hpicfOpenFlowControllerID
Unique ID given to a Controller. This will be
associated with an instance through hpicfOpenFlowInstanceControllerTable. |
Integer32 Constraints: range: 1-65535 |
.1.3.6.1.4.1.11.2.14.11.5.1.89.1.6.1.1 |
||||||||||||||
|
hpicfOpenFlowControllerInetAddressType
Address type of this controller. This
implementation supports only ipv4 type. |
INET-ADDRESS-MIBInetAddressTyper/w Textual Convention: INET-ADDRESS-MIBInetAddressType EnumerationType Values:
|
.1.3.6.1.4.1.11.2.14.11.5.1.89.1.6.1.2 |
||||||||||||||
|
hpicfOpenFlowControllerInetAddress
IP Address of the controller.
|
INET-ADDRESS-MIBInetAddressr/w Textual Convention: INET-ADDRESS-MIBInetAddress OctetStringType Constraints: range: 0..255 |
.1.3.6.1.4.1.11.2.14.11.5.1.89.1.6.1.3 |
||||||||||||||
|
hpicfOpenFlowControllerPort
The port over which the controller can be
reached. |
INET-ADDRESS-MIBInetPortNumberr/w Textual Convention: INET-ADDRESS-MIBInetPortNumber Unsigned32Type Constraints: range: 0..65535 |
.1.3.6.1.4.1.11.2.14.11.5.1.89.1.6.1.4 |
||||||||||||||
|
hpicfOpenFlowControllerInterface
This MIB object specifies an interface over
which the controller is reachable. |
IF-MIBInterfaceIndexr/w Textual Convention: IF-MIBInterfaceIndex Integer32Type Constraints: range: 1..2147483647 |
.1.3.6.1.4.1.11.2.14.11.5.1.89.1.6.1.5 |
||||||||||||||
|
hpicfOpenFlowControllerRowStatus
Row status for this table. The
hpicfOpenFlowControllerInetAddress and hpicfOpenFlowControllerInterface MIB objects have to be set to valid values to move this object to 'active' state. This conceptual row can be de… |
SNMPv2-TCRowStatusr/w Textual Convention: SNMPv2-TCRowStatus EnumerationType Values:
|
.1.3.6.1.4.1.11.2.14.11.5.1.89.1.6.1.6 |
||||||||||||||
|
hpicfOpenFlowControllerSourceAddressType
Address type of the Source IP. This
implementation supports only ipv4 type. |
INET-ADDRESS-MIBInetAddressTyper/w Textual Convention: INET-ADDRESS-MIBInetAddressType EnumerationType Values:
|
.1.3.6.1.4.1.11.2.14.11.5.1.89.1.6.1.7 |
||||||||||||||
|
hpicfOpenFlowControllerSourceAddress
Source IP address to use when connecting
to the controller. |
INET-ADDRESS-MIBInetAddressr/w Textual Convention: INET-ADDRESS-MIBInetAddress OctetStringType Constraints: range: 0..255 |
.1.3.6.1.4.1.11.2.14.11.5.1.89.1.6.1.8 |
.1.3.6.1.4.1.11.2.14.11.5.1.89.1.8
·
1 row entry
·
5 columns
Table that contains objects for connection state and status between an OpenFlow instance and a controller.
A set of objects used to monitor the status
and state of connection between an OpenFlow
instance and controller.
and state of connection between an OpenFlow
instance and controller.
Indexes
hpicfOpenFlowInstanceName hpicfOpenFlowControllerID
| Column | Syntax | OID | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
hpicfOpenFlowInstanceControllerStatus
Connection status between an OpenFlow
instance and a controller. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.11.2.14.11.5.1.89.1.8.1.1 |
||||||||||||
|
hpicfOpenFlowInstanceControllerState
Connection state between an OpenFlow
instance and a controller. The state 'void' implies that there is no connection. The state 'backoff' represents a state where the device is attempting to reconnect to the controll… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.11.2.14.11.5.1.89.1.8.1.2 |
||||||||||||
|
hpicfOpenFlowInstanceControllerRole
Role of a controller in an instance. The
default role of a controller is equal. In this role, the controller has full access to the switch and is equal to other controllers in the same role. In member role, the cont… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.11.2.14.11.5.1.89.1.8.1.3 |
||||||||||||
|
hpicfOpenFlowInstanceControllerConnSecure
This object indicates if the connection
between the controller and instance is secure. Setting this MIB to true will initiate TLS as transport protocol. |
SNMPv2-TCTruthValuer/w Textual Convention: SNMPv2-TCTruthValue EnumerationType Values:
|
.1.3.6.1.4.1.11.2.14.11.5.1.89.1.8.1.4 |
||||||||||||
|
hpicfOpenFlowInstanceControllerRowStatus
Row status for this table. Row transition to
'createAndWait', 'notReady' and 'notInService' states are not allowed. |
SNMPv2-TCRowStatusr/w Textual Convention: SNMPv2-TCRowStatus EnumerationType Values:
|
.1.3.6.1.4.1.11.2.14.11.5.1.89.1.8.1.5 |
.1.3.6.1.4.1.11.2.14.11.5.1.89.1.19
·
1 row entry
·
5 columns
Table that contains objects related to meters of an OpenFlow instance. This table is populated when meters are configured from controller.
A set of objects used to retrieve details
about meters associated with an OpenFlow instance.
about meters associated with an OpenFlow instance.
Indexes
hpicfOpenFlowInstanceName hpicfOpenFlowInstanceMeterID
| Column | Syntax | OID |
|---|---|---|
|
hpicfOpenFlowInstanceMeterID
Unique ID given to a meter.
|
Unsigned32 Constraints: range: 1-65535 |
.1.3.6.1.4.1.11.2.14.11.5.1.89.1.19.1.1 |
|
hpicfOpenFlowInstanceMeterFlowCount
Number of flows on which this meter
is applied. |
SNMPv2-SMIUnsigned32 Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.11.2.14.11.5.1.89.1.19.1.2 |
|
hpicfOpenFlowInstanceMeterInputPktCount
Number of packets processed by this meter.
|
SNMPv2-SMICounter64 Textual Convention: SNMPv2-SMICounter64 Unsigned64Type Constraints: range: 0..18446744073709551615 |
.1.3.6.1.4.1.11.2.14.11.5.1.89.1.19.1.3 |
|
hpicfOpenFlowInstanceMeterInputByteCount
Number of bytes processed by this meter.
|
SNMPv2-SMICounter64 Textual Convention: SNMPv2-SMICounter64 Unsigned64Type Constraints: range: 0..18446744073709551615 |
.1.3.6.1.4.1.11.2.14.11.5.1.89.1.19.1.4 |
|
hpicfOpenFlowInstanceMeterDuration
Duration for which this meter is active.
|
secondsSNMPv2-SMIUnsigned32 Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.11.2.14.11.5.1.89.1.19.1.5 |
.1.3.6.1.4.1.11.2.14.11.5.1.89.1.20
·
1 row entry
·
7 columns
Table that contains objects related to meter bands for a specific meter in an OpenFlow instance. This table is populated when meters and their bands are configured from controller.
A set of objects used to retrieve details
about meter bands associated with a meter and
an OpenFlow instance.
about meter bands associated with a meter and
an OpenFlow instance.
Indexes
hpicfOpenFlowInstanceName hpicfOpenFlowInstanceMeterID hpicfOpenFlowInstanceMeterBandID
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
hpicfOpenFlowInstanceMeterBandID
Unique ID given to a band in a meter.
|
SNMPv2-SMIUnsigned32 Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.11.2.14.11.5.1.89.1.20.1.1 |
||||
|
hpicfOpenFlowInstanceMeterBandType
This meter band type determines how the
packets are processed. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.11.2.14.11.5.1.89.1.20.1.2 |
||||
|
hpicfOpenFlowInstanceMeterBandRate
This MIB object specifies the rate beyond
which the incoming packets would be treated according to action specified by hpicfOpenFlowInstanceMeterBandType MIB. The units of this rate is determined by the hpicfOpenFlo… |
SNMPv2-SMIUnsigned32 Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.11.2.14.11.5.1.89.1.20.1.3 |
||||
|
hpicfOpenFlowInstanceMeterBandRateUnit
This MIB object specifies the unit for
hpicfOpenFlowInstanceMeterBandRate MIB. The units can be either kilobits per second or packets per second. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.11.2.14.11.5.1.89.1.20.1.4 |
||||
|
hpicfOpenFlowInstanceMeterInBandPktCount
Number of packets processed by this meter.
|
SNMPv2-SMICounter64 Textual Convention: SNMPv2-SMICounter64 Unsigned64Type Constraints: range: 0..18446744073709551615 |
.1.3.6.1.4.1.11.2.14.11.5.1.89.1.20.1.5 |
||||
|
hpicfOpenFlowInstanceMeterInBandByteCount
Number of bytes processed by this meter.
|
SNMPv2-SMICounter64 Textual Convention: SNMPv2-SMICounter64 Unsigned64Type Constraints: range: 0..18446744073709551615 |
.1.3.6.1.4.1.11.2.14.11.5.1.89.1.20.1.6 |
||||
|
hpicfOpenFlowInstanceMeterPrecedenceLevel
DSCP Precedence level of the band in a meter.
|
SNMPv2-SMIUnsigned32 Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.11.2.14.11.5.1.89.1.20.1.7 |