querxPhySensorTable
table.1.3.6.1.4.1.3444.1.14.1.2
·
1 row entry
·
10 columns
This table contains one row per physical sensor.
Information about a particular physical sensor.
An entry in this table describes the present reading of a
sensor, the measurement units and scale, and sensor
operational status.
Entries are cre…
An entry in this table describes the present reading of a
sensor, the measurement units and scale, and sensor
operational status.
Entries are cre…
Indexes
querxPhySensorIndex
| Column | Syntax | OID | ||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
querxPhySensorIndex
A unique value, greater than zero, for each sensor.
|
QuerxSensorIndex Textual Convention: QuerxSensorIndex Integer32Type Constraints: range: 1..2147483647 |
.1.3.6.1.4.1.3444.1.14.1.2.1.1 |
||||||||||||||||||||||||||||||||||
|
querxPhySensorType
The type of data returned by the associated
querxPhySensorValue object. This object SHOULD be set by the agent during entry creation, and the value SHOULD NOT change during operation. |
QuerxSensorDataType Textual Convention: QuerxSensorDataType EnumerationType Values:
|
.1.3.6.1.4.1.3444.1.14.1.2.1.2 |
||||||||||||||||||||||||||||||||||
|
querxPhySensorScale
The exponent to apply to values returned by the associated
querxPhySensorValue object. |
QuerxSensorDataScale Textual Convention: QuerxSensorDataScale EnumerationType Values:
|
.1.3.6.1.4.1.3444.1.14.1.2.1.3 |
||||||||||||||||||||||||||||||||||
|
querxPhySensorPrecision
The number of decimal places of precision in fixed-point
sensor values returned by the associated querxPhySensorValue object. This object SHOULD be set to '0' when the associated querxPhySensorType value … |
QuerxSensorPrecision Textual Convention: QuerxSensorPrecision Integer32Type Constraints: range: -8..9 |
.1.3.6.1.4.1.3444.1.14.1.2.1.4 |
||||||||||||||||||||||||||||||||||
|
querxPhySensorValue
The most recent measurement obtained by the agent for this
sensor. To correctly interpret the value of this object, the associated querxPhySensorType, querxPhySensorScale, and querxPhySensorPrecision obje… |
QuerxSensorValue Textual Convention: QuerxSensorValue Integer32Type Constraints: range: -1000000000..1000000000 |
.1.3.6.1.4.1.3444.1.14.1.2.1.5 |
||||||||||||||||||||||||||||||||||
|
querxPhySensorOperStatus
The operational status of the sensor.
|
QuerxSensorStatus Textual Convention: QuerxSensorStatus EnumerationType Values:
|
.1.3.6.1.4.1.3444.1.14.1.2.1.6 |
||||||||||||||||||||||||||||||||||
|
querxPhySensorUnitsDisplay
A textual description of the data units that should be used
in the display of querxPhySensorValue. |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.3444.1.14.1.2.1.7 |
||||||||||||||||||||||||||||||||||
|
querxPhySensorValueTimeStamp
The value of sysUpTime at the time the status and/or value
of this sensor was last obtained by the agent. |
.1.3.6.1.4.1.3444.1.14.1.2.1.8 |
|||||||||||||||||||||||||||||||||||
|
querxPhySensorValueUpdateRate
An indication of the frequency that the agent updates the
associated querxPhySensorValue object, representing in milliseconds. The value zero indicates: - the sensor value is updated on… |
millisecondsSNMPv2-SMIUnsigned32 Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.3444.1.14.1.2.1.9 |
||||||||||||||||||||||||||||||||||
|
querxPhySensorName
The textual name of the physical sensor.
If there is no local name, or if this object is otherwise not applicable, then this object contains a zero-length string. |
OctetString Constraints: range: 0-31 |