querxPhySensorType
EGNITEPHYSENSOR-MIB ·
.1.3.6.1.4.1.3444.1.14.1.2.1.2
Object
column
QuerxSensorDataType
The type of data returned by the associated
querxPhySensorValue object.
This object SHOULD be set by the agent during entry
creation, and the value SHOULD NOT change during operation.
Context
- MIB
- EGNITEPHYSENSOR-MIB
- OID
.1.3.6.1.4.1.3444.1.14.1.2.1.2- Type
- column
- Access
- readonly
- Status
- current
- Parent
- querxPhySensorEntry
- Table
- querxPhySensorTable
- Siblings
- 9
Syntax
QuerxSensorDataType
- Source
- QuerxSensorDataType
- Base type
Enumeration
Values & Constraints
Type Values
1 | other |
2 | unknown |
3 | voltsAC |
4 | voltsDC |
5 | amperes |
6 | watts |
7 | hertz |
8 | celsius |
9 | percentRH |
10 | rpm |
11 | cmm |
12 | truthvalue |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| querxPhySensorIndex A unique value, greater than zero, for each sensor. | column | QuerxSensorIndex | .1.3.6.1.4.1.3444.1.14.1.2.1.1 |
| querxPhySensorName The textual name of the physical sensor.
If there is no local name, or if this object is otherwise
not applicable, then this object contains a zero-length
string. | column | OctetString | .1.3.6.1.4.1.3444.1.14.1.2.1.10 |
| querxPhySensorScale The exponent to apply to values returned by the associated
querxPhySensorValue object. | column | QuerxSensorDataScale | .1.3.6.1.4.1.3444.1.14.1.2.1.3 |
| querxPhySensorPrecision The number of decimal places of precision in fixed-point
sensor values returned by the associated querxPhySensorValue
object.
This object SHOULD be set to '0' when … | column | QuerxSensorPrecision | .1.3.6.1.4.1.3444.1.14.1.2.1.4 |
| querxPhySensorValue The most recent measurement obtained by the agent for this
sensor.
To correctly interpret the value of this object, the
associated querxPhySensorType, querxPhySenso… | column | QuerxSensorValue | .1.3.6.1.4.1.3444.1.14.1.2.1.5 |
| querxPhySensorOperStatus The operational status of the sensor. | column | QuerxSensorStatus | .1.3.6.1.4.1.3444.1.14.1.2.1.6 |
| querxPhySensorUnitsDisplay A textual description of the data units that should be used
in the display of querxPhySensorValue. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.3444.1.14.1.2.1.7 |
| querxPhySensorValueTimeStamp The value of sysUpTime at the time the status and/or value
of this sensor was last obtained by the agent. | column | - | .1.3.6.1.4.1.3444.1.14.1.2.1.8 |
| querxPhySensorValueUpdateRate An indication of the frequency that the agent updates the
associated querxPhySensorValue object, representing in
milliseconds.
The value zero indicates: