querxPhySensorValue
EGNITEPHYSENSOR-MIB ·
.1.3.6.1.4.1.3444.1.14.1.2.1.5
Object
column
QuerxSensorValue
The most recent measurement obtained by the agent for this
sensor.
To correctly interpret the value of this object, the
associated querxPhySensorType, querxPhySensorScale, and
querxPhySensorPrecision objects must also be examined.
Context
- MIB
- EGNITEPHYSENSOR-MIB
- OID
.1.3.6.1.4.1.3444.1.14.1.2.1.5- Type
- column
- Access
- readonly
- Status
- current
- Parent
- querxPhySensorEntry
- Table
- querxPhySensorTable
- Siblings
- 9
Syntax
QuerxSensorValue
- Source
- QuerxSensorValue
- Base type
Integer32
Values & Constraints
Type Constraints
range: -1000000000..1000000000
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| querxPhySensorIndex A unique value, greater than zero, for each sensor. | column | QuerxSensorIndex | .1.3.6.1.4.1.3444.1.14.1.2.1.1 |
| querxPhySensorName The textual name of the physical sensor.
If there is no local name, or if this object is otherwise
not applicable, then this object contains a zero-length
string. | column | OctetString | .1.3.6.1.4.1.3444.1.14.1.2.1.10 |
| querxPhySensorType The type of data returned by the associated
querxPhySensorValue object.
This object SHOULD be set by the agent during entry
creation, and the value SHOULD NOT chang… | column | QuerxSensorDataType | .1.3.6.1.4.1.3444.1.14.1.2.1.2 |
| querxPhySensorScale The exponent to apply to values returned by the associated
querxPhySensorValue object. | column | QuerxSensorDataScale | .1.3.6.1.4.1.3444.1.14.1.2.1.3 |
| querxPhySensorPrecision The number of decimal places of precision in fixed-point
sensor values returned by the associated querxPhySensorValue
object.
This object SHOULD be set to '0' when … | column | QuerxSensorPrecision | .1.3.6.1.4.1.3444.1.14.1.2.1.4 |
| querxPhySensorOperStatus The operational status of the sensor. | column | QuerxSensorStatus | .1.3.6.1.4.1.3444.1.14.1.2.1.6 |
| querxPhySensorUnitsDisplay A textual description of the data units that should be used
in the display of querxPhySensorValue. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.3444.1.14.1.2.1.7 |
| querxPhySensorValueTimeStamp The value of sysUpTime at the time the status and/or value
of this sensor was last obtained by the agent. | column | - | .1.3.6.1.4.1.3444.1.14.1.2.1.8 |
| querxPhySensorValueUpdateRate An indication of the frequency that the agent updates the
associated querxPhySensorValue object, representing in
milliseconds.
The value zero indicates:
… | column | milliseconds SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.3444.1.14.1.2.1.9 |