AT-ALMMON-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
5
Rows
5
Columns
27
.1.3.6.1.4.1.207.8.4.4.3.26.1 · 1 row entry · 11 columns
A table of information describing alarm monitoring inputs
and consequent actions (i.e. fault LED & relay outputs).
atAlmMonActionEntry entry .1.3.6.1.4.1.207.8.4.4.3.26.1.1
The description and configuration of what to do for a specific monitored alarm.
Indexes
atAlmMonActionStackMemberId atAlmMonActionIndex
Column Syntax OID
atAlmMonActionStackMemberId
The index of the stack member of this alarm action.
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.207.8.4.4.3.26.1.1.1
atAlmMonActionIndex
The numeric identifier of this alarm action.
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.207.8.4.4.3.26.1.1.2
atAlmMonAlarmType
The type of alarm that this action monitors.
AtAlmMonAlarmType
Textual Convention: AtAlmMonAlarmType Enumeration
Type Values:
1externalPSU
2epsr
3contactInput
4portLinkDown
5loopDetect
6mainPse
7portPoeFailure
8temperature
9g8032
10ufo
.1.3.6.1.4.1.207.8.4.4.3.26.1.1.3
atAlmMonAlarmTypeSelection
The 1-based index of the alarm of the particular type (as catagorised by atAlmMonAlarmType).
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.207.8.4.4.3.26.1.1.4
atAlmMonActionDescription
The description of this alarm monitoring entry.
OctetString
Constraints:
range: 0-30
.1.3.6.1.4.1.207.8.4.4.3.26.1.1.5
atAlmMonActionUseRelay1
Indicates/controls whether or not this alarm monitor drives the first relay output.
AtAlmMonActionUseOutputr/w
Textual Convention: AtAlmMonActionUseOutput Enumeration
Type Values:
1unused
2used
.1.3.6.1.4.1.207.8.4.4.3.26.1.1.6
atAlmMonActionUseRelay2
Indicates/controls whether or not this alarm monitor drives the second relay output.
AtAlmMonActionUseOutputr/w
Textual Convention: AtAlmMonActionUseOutput Enumeration
Type Values:
1unused
2used
.1.3.6.1.4.1.207.8.4.4.3.26.1.1.7
atAlmMonActionUseRelay3
Indicates/controls whether or not this alarm monitor drives the third relay output.
AtAlmMonActionUseOutputr/w
Textual Convention: AtAlmMonActionUseOutput Enumeration
Type Values:
1unused
2used
.1.3.6.1.4.1.207.8.4.4.3.26.1.1.8
atAlmMonActionUseFaultLed
Indicates/controls whether or not this alarm monitor drives the fault LED.
AtAlmMonActionUseOutputr/w
Textual Convention: AtAlmMonActionUseOutput Enumeration
Type Values:
1unused
2used
.1.3.6.1.4.1.207.8.4.4.3.26.1.1.9
atAlmMonAbnormalState
Indicates/sets the abnormal (i.e. alarm active) state for a contact input.
Only used for contactInput alarm monitors, ignored for all other types.
AtAlmMonAbnormalStater/w
Textual Convention: AtAlmMonAbnormalState Enumeration
Type Values:
1open
2closed
.1.3.6.1.4.1.207.8.4.4.3.26.1.1.10
atAlmMonActionState
Indicates the current state of this alarm monitor.
AtAlmMonActionState
Textual Convention: AtAlmMonActionState Enumeration
Type Values:
1inactive
2active
.1.3.6.1.4.1.207.8.4.4.3.26.1.1.11
.1.3.6.1.4.1.207.8.4.4.3.26.3 · 1 row entry · 6 columns
A table of information listing available alarms on the device.
atAlmMonAvailableEntry entry .1.3.6.1.4.1.207.8.4.4.3.26.3.1
The description and configuration of each available alarm.
Indexes
atAlmMonAvailableAlarmId
Column Syntax OID
atAlmMonAvailableAlarmId
The unique numeric identifier for this alarm.
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.207.8.4.4.3.26.3.1.1
atAlmMonAvailableType
The type of this alarm, such as externalPSU(1), epsr(2), etc.
AtAlmMonAlarmType
Textual Convention: AtAlmMonAlarmType Enumeration
Type Values:
1externalPSU
2epsr
3contactInput
4portLinkDown
5loopDetect
6mainPse
7portPoeFailure
8temperature
9g8032
10ufo
.1.3.6.1.4.1.207.8.4.4.3.26.3.1.2
atAlmMonAvailableTypeIndex
The index of the particular alarm type (catagorised by atAlmMonAlarmType).

For some alarms there are multiple sources on the device (i.e. power supplies).
In these cases this object indicates which source…
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.207.8.4.4.3.26.3.1.3
atAlmMonAvailableStkId
The id of stack member this alarm triggers on.

This object is used for externalPSU(1), contactInput(3), portLinkDown(4),
portPoeFailure(7) and temperature(8) alarm only.
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.207.8.4.4.3.26.3.1.4
atAlmMonAvailableIfName
The name of the specific interface that this alarm triggers on, such as 'port1.0.1.

This object is used for portLinkDown(4) and portPoeFailure(7) alarm only.
OctetString
Constraints:
range: 0-32
.1.3.6.1.4.1.207.8.4.4.3.26.3.1.5
atAlmMonAvailableState
Indicates the current state of this alarm.
AtAlmMonActionState
Textual Convention: AtAlmMonActionState Enumeration
Type Values:
1inactive
2active
.1.3.6.1.4.1.207.8.4.4.3.26.3.1.6
.1.3.6.1.4.1.207.8.4.4.3.26.4 · 1 row entry · 4 columns
This table lists all associations existing on the device between output
relays and alarms.
          
Theoretically, an output relay on the device can be triggered by multiple
alarms and an alarm can trigger multiple output relays.
atAlmMonOutputRelayEntry entry .1.3.6.1.4.1.207.8.4.4.3.26.4.1
This entry reprents an association between one ouput relay and one alarm.

To configure an alarm to use an output relay, a user needs to create a new
entry. This can be done through writing a value of used(2…
Indexes
atAlmMonOutputRelayStkId atAlmMonOutputRelayNumber atAlmMonOutputRelayAlarmId
Column Syntax OID
atAlmMonOutputRelayStkId
The id of stack member that the relay(s) reside on.
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.207.8.4.4.3.26.4.1.1
atAlmMonOutputRelayNumber
The number (i.e. the 1 based index) of the relay.
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.207.8.4.4.3.26.4.1.2
atAlmMonOutputRelayAlarmId
The id of the alarm that may use this relay output.
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.207.8.4.4.3.26.4.1.3
atAlmMonOutputRelayUsage
This object indicates whether or not the relay output is used.

Since there are entries only for existing associations between the output
relays and the alarms, the object value should be always used(2).
AtAlmMonActionUseOutputr/w
Textual Convention: AtAlmMonActionUseOutput Enumeration
Type Values:
1unused
2used
.1.3.6.1.4.1.207.8.4.4.3.26.4.1.4
.1.3.6.1.4.1.207.8.4.4.3.26.5 · 1 row entry · 3 columns
This table lists all associations existing on the device between output
LED(s) and alarms.
          
Theoretically, an output LED on the device can be triggered by multiple
alarms and an alarm can trigger multiple LED(s).
atAlmMonOutputLedEntry entry .1.3.6.1.4.1.207.8.4.4.3.26.5.1
This entry reprents an association between one LED and one alarm.

To configure an alarm to use an output LED, a user needs to create a new
entry. This can be done through writing a value of used(2) to objec…
Indexes
atAlmMonOutputRelayStkId atAlmMonOutputRelayAlarmId
Column Syntax OID
atAlmMonOutputLedStkId
The id of stack member that the output LED resides on.
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.207.8.4.4.3.26.5.1.1
atAlmMonOutputLedAlarmId
The id of the alarm that may use this output LED.
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.207.8.4.4.3.26.5.1.2
atAlmMonOutputLedUsage
This object indicates whether or not an LED is used.

Since there are entries only for existing associations between the output
LED(s) and the alarms, the object value should be always used(2).
AtAlmMonActionUseOutputr/w
Textual Convention: AtAlmMonActionUseOutput Enumeration
Type Values:
1unused
2used
.1.3.6.1.4.1.207.8.4.4.3.26.5.1.3
.1.3.6.1.4.1.207.8.4.4.3.26.6 · 1 row entry · 3 columns
This table lists all input contacts on the device and their positions.
atAlmMonInputContactEntry entry .1.3.6.1.4.1.207.8.4.4.3.26.6.1
The information of each input contact configuration.
Indexes
atAlmMonInputContactStkId atAlmMonInputContactNumber
Column Syntax OID
atAlmMonInputContactStkId
The id of stack member that the input contact reside on.
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.207.8.4.4.3.26.6.1.1
atAlmMonInputContactNumber
The number (i.e. the 1 based index) of the input contact.
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.207.8.4.4.3.26.6.1.2
atAlmMonInputContactPosition
This object represents the position of the input contact. It is either
open or closed.
A user can reconfigure the position of an input contact by setting
a different value to this object.
AtAlmMonContactPositionr/w
Textual Convention: AtAlmMonContactPosition Enumeration
Type Values:
1open
2closed
.1.3.6.1.4.1.207.8.4.4.3.26.6.1.3