atAlmMonActionEntry
AT-ALMMON-MIB ·
.1.3.6.1.4.1.207.8.4.4.3.26.1.1
Object
row
The description and configuration of what to do for a specific monitored alarm.
Context
- MIB
- AT-ALMMON-MIB
- OID
.1.3.6.1.4.1.207.8.4.4.3.26.1.1- Type
- row
- Status
- current
- Parent
- atAlmMonActionTable
- Table
- atAlmMonActionTable
- Children
- 11
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| atAlmMonActionStackMemberId The index of the stack member of this alarm action. | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.207.8.4.4.3.26.1.1.1 |
| atAlmMonAbnormalState Indicates/sets the abnormal (i.e. alarm active) state for a contact input.
Only used for contactInput alarm monitors, ignored for all other types. | column | AtAlmMonAbnormalState | .1.3.6.1.4.1.207.8.4.4.3.26.1.1.10 |
| atAlmMonActionState Indicates the current state of this alarm monitor. | column | AtAlmMonActionState | .1.3.6.1.4.1.207.8.4.4.3.26.1.1.11 |
| atAlmMonActionIndex The numeric identifier of this alarm action. | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.207.8.4.4.3.26.1.1.2 |
| atAlmMonAlarmType The type of alarm that this action monitors. | column | AtAlmMonAlarmType | .1.3.6.1.4.1.207.8.4.4.3.26.1.1.3 |
| atAlmMonAlarmTypeSelection The 1-based index of the alarm of the particular type (as catagorised by atAlmMonAlarmType). | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.207.8.4.4.3.26.1.1.4 |
| atAlmMonActionDescription The description of this alarm monitoring entry. | column | OctetString | .1.3.6.1.4.1.207.8.4.4.3.26.1.1.5 |
| atAlmMonActionUseRelay1 Indicates/controls whether or not this alarm monitor drives the first relay output. | column | AtAlmMonActionUseOutput | .1.3.6.1.4.1.207.8.4.4.3.26.1.1.6 |
| atAlmMonActionUseRelay2 Indicates/controls whether or not this alarm monitor drives the second relay output. | column | AtAlmMonActionUseOutput | .1.3.6.1.4.1.207.8.4.4.3.26.1.1.7 |
| atAlmMonActionUseRelay3 Indicates/controls whether or not this alarm monitor drives the third relay output. | column | AtAlmMonActionUseOutput | .1.3.6.1.4.1.207.8.4.4.3.26.1.1.8 |
| atAlmMonActionUseFaultLed Indicates/controls whether or not this alarm monitor drives the fault LED. | column | AtAlmMonActionUseOutput | .1.3.6.1.4.1.207.8.4.4.3.26.1.1.9 |
Indexes
| Object | Type | Syntax | OID |
|---|---|---|---|
| atAlmMonActionStackMemberId The index of the stack member of this alarm action. | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.207.8.4.4.3.26.1.1.1 |
| atAlmMonActionIndex The numeric identifier of this alarm action. | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.207.8.4.4.3.26.1.1.2 |