ADTRAN-TA5K-GR909-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
1
Rows
1
Columns
37
.1.3.6.1.4.1.664.5.67.1.19.1 · 1 row entry · 37 columns
Table of GR909  Table info.
adGenGr909Entry entry .1.3.6.1.4.1.664.5.67.1.19.1.1
Indexes
IF-MIBifIndex
Column Syntax OID
adGenGr909HPTResult
This item indicates the result for the HPT test.
Pass(1) = The HPT test Passed.
Fail(2) = The HPT test failed.
N/A(3) = The HPT test result is not ready.
Enumeration
Enumerated Values:
1pass
2fail
3na
.1.3.6.1.4.1.664.5.67.1.19.1.1.1
adGenGr909FEMFResult
This item indicates the result for the FEMF test.
Pass(1) = The FEMF test Passed.
Fail(2) = The FEMF test failed.
N/A(3) = The FEMF test result is not ready.
Enumeration
Enumerated Values:
1pass
2fail
3na
.1.3.6.1.4.1.664.5.67.1.19.1.1.2
adGenGr909RFaultResult
This item indicates the result for the RFault test.
Pass(1) = The RFault test Passed.
Fail(2) = The RFault test failed.
N/A(3) = The RFault test result is not ready.
Enumeration
Enumerated Values:
1pass
2fail
3na
.1.3.6.1.4.1.664.5.67.1.19.1.1.3
adGenGr909RingerResult
This item indicates the result for the Ringer test.
Pass(1) = The Ringer test Passed.
Fail(2) = The Ringer test failed.
N/A(3) = The Ringer test result is not ready.
Enumeration
Enumerated Values:
1pass
2fail
3na
.1.3.6.1.4.1.664.5.67.1.19.1.1.4
adGenGr909ROHResult
This item indicates the result for the ROH test.
Pass(1) = The ROH test Passed.
Fail(2) = The ROH test failed.
N/A(3) = The ROH test result is not ready.
Enumeration
Enumerated Values:
1pass
2fail
3na
.1.3.6.1.4.1.664.5.67.1.19.1.1.5
adGenGr909FVAcTipToGndMeas
The value for the Foreign Voltage AC
Tip to Ground measurement.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.664.5.67.1.19.1.1.6
adGenGr909FVAcRingToGndMeas
The value for the Foreign Voltage AC
Ring to Ground measurement.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.664.5.67.1.19.1.1.7
adGenGr909FVDcTipToGndMeas
The value for the Foreign Voltage DC
Tip to Ground measurement.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.664.5.67.1.19.1.1.8
adGenGr909FVDcRingToGndMeas
The value for the Foreign Voltage DC
Ring to Ground measurement.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.664.5.67.1.19.1.1.9
adGenGr909FVAcTipToGndResult
The result for the Foreign Voltage AC
Tip to Ground test.
Enumeration
Enumerated Values:
1pass
2fail
.1.3.6.1.4.1.664.5.67.1.19.1.1.10
adGenGr909FVAcRingToGndResult
The result for the Foreign Voltage AC
Ring to Ground test.
Enumeration
Enumerated Values:
1pass
2fail
.1.3.6.1.4.1.664.5.67.1.19.1.1.11
adGenGr909FVDcTipToGndResult
The result for the Foreign Voltage DC
Tip to Ground test.
Enumeration
Enumerated Values:
1pass
2fail
.1.3.6.1.4.1.664.5.67.1.19.1.1.12
adGenGr909FVDcRingToGndResult
The result for the Foreign Voltage DC
Ring to Ground test.
Enumeration
Enumerated Values:
1pass
2fail
.1.3.6.1.4.1.664.5.67.1.19.1.1.13
adGenGr909LoopImpTipToRingMeas
The value for the Loop Impedance
Tip to Ring measurement.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.664.5.67.1.19.1.1.14
adGenGr909LoopImpTipToGndMeas
The value for the Loop Impedance
Tip to Ground measurement.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.664.5.67.1.19.1.1.15
adGenGr909LoopImpRingToGndMeas
The value for the Loop Impedance
Ring to Ground measurement.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.664.5.67.1.19.1.1.16
adGenGr909LoopImpTipToRingResult
The result for the Loop Impedance
Tip to Ring test.
Enumeration
Enumerated Values:
1pass
2fail
.1.3.6.1.4.1.664.5.67.1.19.1.1.17
adGenGr909LoopImpTipToGndResult
The result for the Loop Impedance
Tip to Ground test.
Enumeration
Enumerated Values:
1pass
2fail
.1.3.6.1.4.1.664.5.67.1.19.1.1.18
adGenGr909LoopImpRingToGndResult
The result for the Loop Impedance
Ring to Ground test.
Enumeration
Enumerated Values:
1pass
2fail
.1.3.6.1.4.1.664.5.67.1.19.1.1.19
adGenGr909RingerMeas
The value for the Ringer measurement.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.664.5.67.1.19.1.1.20
adGenGr909LastTestComplete
The last test time the GR909 test was completed.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.664.5.67.1.19.1.1.21
adGenGr909LastTestAttempt
The last test time the GR909 test was completed.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.664.5.67.1.19.1.1.22
adGenGr909LastTestResult
This item indicates the result for the last test.
N/A(1) = The last test result is not valid.
Complete(2) = The last test is Complete.
Fault(3) = The last test had a fault.
Running(4) = The test is running.
Enumeration
Enumerated Values:
1na
2complete
3fault
4running
.1.3.6.1.4.1.664.5.67.1.19.1.1.23
adGenGr909FailureCode
The Failure Code for the last GR909 test.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.664.5.67.1.19.1.1.24
adGenGr909BeginTest
Begin running the GR909 test.
Enumerationr/w
Enumerated Values:
1begin
.1.3.6.1.4.1.664.5.67.1.19.1.1.25
adGenGr909LoopCapTipToRingMeas
The value for the Loop Capacitance
Tip to Ring measurement.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.664.5.67.1.19.1.1.26
adGenGr909LoopCapTipToGndMeas
The value for the Loop Capacitance
Tip to Ground measurement.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.664.5.67.1.19.1.1.27
adGenGr909LoopCapRingToGndMeas
The value for the Loop Capacitance
Ring to Ground measurement.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.664.5.67.1.19.1.1.28
adGenGr909IdleNoiseMeasure
Noise on the line.
-0.001 dBmInteger32
Constraints:
range: 0-120000
.1.3.6.1.4.1.664.5.67.1.19.1.1.29
adGenGr909IdleNoiseResult
The result of the noise measurement test on the line.
pass(1) = Idle Channel Noise Measurement passed.
fail(2) = Idle Channel Noise Measurement exceeded threshold.
na(3) = Idle Channel Measurement results are invalid, b…
Enumeration
Enumerated Values:
1pass
2fail
3na
.1.3.6.1.4.1.664.5.67.1.19.1.1.30
adGenGr909NumLoadCoils
Number of load coils on the line.
Integer32
Constraints:
range: 0-10
.1.3.6.1.4.1.664.5.67.1.19.1.1.31
adGenGr909LoadCoilsDistance
Returns a vector of 32-bit unsigned integers (split into octets)
containing the measured distance to each detected load coil
in feet.
If no load coil is detected then the system will return
a NULL. If one load coil is…
OctetString .1.3.6.1.4.1.664.5.67.1.19.1.1.32
adGenGr909LoadCoilsResult
This item indicates the result for the load coils test.
Valid(1) = The load coil test results are valid.
Invalid(2) = The load coil test results are invalid.
Enumeration
Enumerated Values:
1valid
2invalid
.1.3.6.1.4.1.664.5.67.1.19.1.1.33
adGenGr909TestFlag
Use to enable/disable the GR909 line tests.
Enumerationr/w
Enumerated Values:
1enable
2disable
.1.3.6.1.4.1.664.5.67.1.19.1.1.34
adGenGr909TestCapFlag
Use to enable/disable the capacitance test on the line.
Enumerationr/w
Enumerated Values:
1enable
2disable
.1.3.6.1.4.1.664.5.67.1.19.1.1.35
adGenGr909TestNoiseFlag
Use to enable/disable the noise test on the line.
Enumerationr/w
Enumerated Values:
1enable
2disable
.1.3.6.1.4.1.664.5.67.1.19.1.1.36
adGenGr909TestLoadCoilFlag
Use to enable/disable the load coil tests on the line.
Enumerationr/w
Enumerated Values:
1enable
2disable
.1.3.6.1.4.1.664.5.67.1.19.1.1.37