adGenGr909LoadCoilsDistance
ADTRAN-TA5K-GR909-MIB ·
.1.3.6.1.4.1.664.5.67.1.19.1.1.32
Object
column
OctetString
Returns a vector of 32-bit unsigned integers (split into octets)
containing the measured distance to each detected load coil
in feet.
If no load coil is detected then the system will return
a NULL. If one load coil is detected, then it will return four bytes
that will contain the distance in feet to that load coil from the node.
Similarly if a second load coil is detected then eight bytes
will be returned with the last four bytes containing the distance
to the second load coil from the node. Since this method allows
detection of up to 5 load coils, possibly 20 bytes containing the
distances to each of the coils from the node could be returned.
For example, a return of 0x00 00 04 1A 00 00 08 7F corresponds
to two load coils at distances of 1050 ft. and 2175 ft. from the node.
Context
- MIB
- ADTRAN-TA5K-GR909-MIB
- OID
.1.3.6.1.4.1.664.5.67.1.19.1.1.32- Type
- column
- Access
- readonly
- Status
- current
- Parent
- adGenGr909Entry
- Table
- adGenGr909Table
- Siblings
- 36
Syntax
OctetString
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| adGenGr909HPTResult This item indicates the result for the HPT test.
Pass(1) = The HPT test Passed.
Fail(2) = The HPT test failed.
N/A(3) = The HPT test result is not ready. | column | Enumeration | .1.3.6.1.4.1.664.5.67.1.19.1.1.1 |
| adGenGr909FVAcTipToGndResult The result for the Foreign Voltage AC
Tip to Ground test. | column | Enumeration | .1.3.6.1.4.1.664.5.67.1.19.1.1.10 |
| adGenGr909FVAcRingToGndResult The result for the Foreign Voltage AC
Ring to Ground test. | column | Enumeration | .1.3.6.1.4.1.664.5.67.1.19.1.1.11 |
| adGenGr909FVDcTipToGndResult The result for the Foreign Voltage DC
Tip to Ground test. | column | Enumeration | .1.3.6.1.4.1.664.5.67.1.19.1.1.12 |
| adGenGr909FVDcRingToGndResult The result for the Foreign Voltage DC
Ring to Ground test. | column | Enumeration | .1.3.6.1.4.1.664.5.67.1.19.1.1.13 |
| adGenGr909LoopImpTipToRingMeas The value for the Loop Impedance
Tip to Ring measurement. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.664.5.67.1.19.1.1.14 |
| adGenGr909LoopImpTipToGndMeas The value for the Loop Impedance
Tip to Ground measurement. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.664.5.67.1.19.1.1.15 |
| adGenGr909LoopImpRingToGndMeas The value for the Loop Impedance
Ring to Ground measurement. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.664.5.67.1.19.1.1.16 |
| adGenGr909LoopImpTipToRingResult The result for the Loop Impedance
Tip to Ring test. | column | Enumeration | .1.3.6.1.4.1.664.5.67.1.19.1.1.17 |
| adGenGr909LoopImpTipToGndResult The result for the Loop Impedance
Tip to Ground test. | column | Enumeration | .1.3.6.1.4.1.664.5.67.1.19.1.1.18 |
| adGenGr909LoopImpRingToGndResult The result for the Loop Impedance
Ring to Ground test. | column | Enumeration | .1.3.6.1.4.1.664.5.67.1.19.1.1.19 |
| adGenGr909FEMFResult This item indicates the result for the FEMF test.
Pass(1) = The FEMF test Passed.
Fail(2) = The FEMF test failed.
N/A(3) = The FEMF test result is not ready. | column | Enumeration | .1.3.6.1.4.1.664.5.67.1.19.1.1.2 |
| adGenGr909RingerMeas The value for the Ringer measurement. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.664.5.67.1.19.1.1.20 |
| adGenGr909LastTestComplete The last test time the GR909 test was completed. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.664.5.67.1.19.1.1.21 |
| adGenGr909LastTestAttempt The last test time the GR909 test was completed. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.664.5.67.1.19.1.1.22 |
| adGenGr909LastTestResult This item indicates the result for the last test.
N/A(1) = The last test result is not valid.
Complete(2) = The last test is Complete.
Fault(3) = The last test had a fault.
Runnin… | column | Enumeration | .1.3.6.1.4.1.664.5.67.1.19.1.1.23 |
| adGenGr909FailureCode The Failure Code for the last GR909 test. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.664.5.67.1.19.1.1.24 |
| adGenGr909BeginTest Begin running the GR909 test. | column | Enumeration | .1.3.6.1.4.1.664.5.67.1.19.1.1.25 |
| adGenGr909LoopCapTipToRingMeas The value for the Loop Capacitance
Tip to Ring measurement. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.664.5.67.1.19.1.1.26 |
| adGenGr909LoopCapTipToGndMeas The value for the Loop Capacitance
Tip to Ground measurement. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.664.5.67.1.19.1.1.27 |
| adGenGr909LoopCapRingToGndMeas The value for the Loop Capacitance
Ring to Ground measurement. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.664.5.67.1.19.1.1.28 |
| adGenGr909IdleNoiseMeasure Noise on the line. | column | -0.001 dBm Integer32 | .1.3.6.1.4.1.664.5.67.1.19.1.1.29 |
| adGenGr909RFaultResult This item indicates the result for the RFault test.
Pass(1) = The RFault test Passed.
Fail(2) = The RFault test failed.
N/A(3) = The RFault test result is not ready. | column | Enumeration | .1.3.6.1.4.1.664.5.67.1.19.1.1.3 |
| adGenGr909IdleNoiseResult The result of the noise measurement test on the line.
pass(1) = Idle Channel Noise Measurement passed.
fail(2) = Idle Channel Noise Measurement exceeded threshold.
na(3) = Idle Ch… | column | Enumeration | .1.3.6.1.4.1.664.5.67.1.19.1.1.30 |
| adGenGr909NumLoadCoils Number of load coils on the line. | column | Integer32 | .1.3.6.1.4.1.664.5.67.1.19.1.1.31 |
| adGenGr909LoadCoilsResult This item indicates the result for the load coils test.
Valid(1) = The load coil test results are valid.
Invalid(2) = The load coil test results are invalid. | column | Enumeration | .1.3.6.1.4.1.664.5.67.1.19.1.1.33 |
| adGenGr909TestFlag Use to enable/disable the GR909 line tests. | column | Enumeration | .1.3.6.1.4.1.664.5.67.1.19.1.1.34 |
| adGenGr909TestCapFlag Use to enable/disable the capacitance test on the line. | column | Enumeration | .1.3.6.1.4.1.664.5.67.1.19.1.1.35 |
| adGenGr909TestNoiseFlag Use to enable/disable the noise test on the line. | column | Enumeration | .1.3.6.1.4.1.664.5.67.1.19.1.1.36 |
| adGenGr909TestLoadCoilFlag Use to enable/disable the load coil tests on the line. | column | Enumeration | .1.3.6.1.4.1.664.5.67.1.19.1.1.37 |
| adGenGr909RingerResult This item indicates the result for the Ringer test.
Pass(1) = The Ringer test Passed.
Fail(2) = The Ringer test failed.
N/A(3) = The Ringer test result is not ready. | column | Enumeration | .1.3.6.1.4.1.664.5.67.1.19.1.1.4 |
| adGenGr909ROHResult This item indicates the result for the ROH test.
Pass(1) = The ROH test Passed.
Fail(2) = The ROH test failed.
N/A(3) = The ROH test result is not ready. | column | Enumeration | .1.3.6.1.4.1.664.5.67.1.19.1.1.5 |
| adGenGr909FVAcTipToGndMeas The value for the Foreign Voltage AC
Tip to Ground measurement. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.664.5.67.1.19.1.1.6 |
| adGenGr909FVAcRingToGndMeas The value for the Foreign Voltage AC
Ring to Ground measurement. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.664.5.67.1.19.1.1.7 |
| adGenGr909FVDcTipToGndMeas The value for the Foreign Voltage DC
Tip to Ground measurement. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.664.5.67.1.19.1.1.8 |
| adGenGr909FVDcRingToGndMeas The value for the Foreign Voltage DC
Ring to Ground measurement. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.664.5.67.1.19.1.1.9 |