zhoneTacTestId
ZHONE-CARD-DIAGNOSTICS-MIB ·
.1.3.6.1.4.1.5504.3.3.7.1.4
Object
column
r/w
Enumeration
This object is only valid for Tac Cards which
support the new Legerity Suite of tests.
This object identifies which test is to
be run, or can be set to abort the current test.
Test results are sent to the zhoneTacTestResultsTable.
There are 3 Legerity software packages: Basic Test (VCP-BT),
Advanced Test (VCP-AT), and Advanced Test Plus (VCP-ATP).
We currently support Basic Test package.
The following lists which tests are supported in each
software package.
Calibration VCP-ATP
Foreign DC Voltage Test VCP-BT, VCP-AT, VCP-ATP
Foreign AC VoltageTest VCP-BT, VCP-AT, VCP-ATP
DC Loop Resistance Test VCP-BT, VCP-AT, VCP-ATP
Three-Element Insulation Resistance Test VCP-BT, VCP-AT, VCP-ATP
Five-Element Insulation Resistance Test VCP-ATP
Three-Element Capacitance Test VCP-BT, VCP-AT
Receiver Off-Hook Test VCP-BT, VCP-AT, VCP-ATP
Distance to Open Test VCP-BT, VCP-AT
Foreign AC Currents Test VCP-BT, VCP-AT
Ringer Equivalency Number Test VCP-BT, VCP-AT, VCP-ATP
DTMF and Pulse Digit Measurement Test VCP-BT, VCP-AT
Noise Measurement Test VCP-BT, VCP-AT, VCP-ATP
Signal to Noise Ratio Test VCP-ATP
Arbitrary Single Tone Measurement Test VCP-ATP
Tone Generation Test VCP-BT, VCP-AT
Trans-Hybrid Loss Test VCP-BT, VCP-AT, VCP-ATP
Draw and Break Dial Tone Test VCP-BT, VCP-AT
Inward Current Test VCP-ATP
DC Feed Self-Test VCP-BT, VCP-AT, VCP-ATP
On/Off Hook Self-Test VCP-BT, VCP-AT, VCP-ATP
Ringing Self-Test VCP-BT, VCP-AT, VCP-ATP
Ringing Monitor Test VCP-BT, VCP-AT, VCP-ATP
Metering Self-Test VCP-BT, VCP-AT
Transmission Self-Test VCP-BT, VCP-AT, VCP-ATP
Dialing Sef Test VCP-BT, VCP-AT
Howler Test VCP-BT, VCP-AT
Fuse Test VCP-ATP
Read Loop and Battery Conditions VCP-BT, VCP-AT, VCP-ATP
Context
- MIB
- ZHONE-CARD-DIAGNOSTICS-MIB
- OID
.1.3.6.1.4.1.5504.3.3.7.1.4- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- zhoneTacTestEntry
- Table
- zhoneTacTestTable
- Siblings
- 8
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | none |
2 | runAllTests |
3 | abortTest |
4 | calibration |
5 | foreignDCVoltage |
6 | foreignACVoltage |
7 | dcLoopResistance |
8 | threeElementInsulationResistance |
9 | fiveElementInsulationResistance |
10 | threeElementCapacitance |
11 | receiverOffHook |
12 | distanceToOpen |
13 | foreignACCurrents |
14 | ringerEquivalencyNumber |
15 | dtmfAndPulseDigitMeasurement |
16 | noiseMeasurement |
17 | signalToNoiseRatio |
18 | arbitrarySignalToneMeasurement |
19 | toneGeneration |
20 | transHybridLoss |
21 | drawAndBreakDialTone |
22 | inwardCurrent |
23 | dcFeedSelf |
24 | onAndOffHookSelfTest |
25 | ringingSelfTest |
26 | ringingMonitor |
27 | meteringSelfTest |
28 | transmissionSelfTest |
29 | dialingSelfTest |
30 | howlerTest |
31 | fuseTest |
32 | readLoopAndBatteryConditions |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| zhoneTacIndex This field is the index field for the tac test
channel which will be connected on the external
port. This device supports a maximum of two channels,
one or both channels may be su… | column | Integer32 | .1.3.6.1.4.1.5504.3.3.7.1.1 |
| zhoneTacInterfaceIndex This field contains the InterfaceIndex of the physical line to
be tested. If no line is currently being tested this
value is 0.
The ability of a physical line type … | column | IF-MIBInterfaceIndexOrZero | .1.3.6.1.4.1.5504.3.3.7.1.2 |
| zhoneTacTestMode This field is used to set the mtac test mode for a
given line. The options are:
mtacModeBridge - All traffic on the given line is bridged
across the mtac lines
mtac… | column | Enumeration | .1.3.6.1.4.1.5504.3.3.7.1.3 |
| zhoneTacTestParam1 Optional Test Parameter #1 | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.5504.3.3.7.1.5 |
| zhoneTacTestParam2 Optional Test Paramerter #2 | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.5504.3.3.7.1.6 |
| zhoneTacTestParam3 Optional Test Parameter #3 | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.5504.3.3.7.1.7 |
| zhoneTacTestParam4 Optional Test Parameter #4 | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.5504.3.3.7.1.8 |
| zhoneTacTestParam5 Optional Test Parameter #5
Value: