xdsl2LConfProfClassMask
VDSL2-LINE-MIB ·
.1.3.6.1.2.1.10.251.1.5.1.3.1.10
Object
In order to reduce the number of configuration possibilities, the limit Power Spectral Density masks (see LIMITMASK) are grouped in PSD mask classes. Each class is designed such that the PSD levels of each limit PSD mask of a specific class are equal in their respective passband above 552 kHz. This parameter is defined per VDSL2 Annex enabled in the xdsl2LConfProfXtuTransSysEna object. It selects a single PSD mask class per Annex that is activated at the VTU-O.
Context
- MIB
- VDSL2-LINE-MIB
- OID
.1.3.6.1.2.1.10.251.1.5.1.3.1.10- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- xdsl2LineConfProfModeSpecEntry
- Table
- xdsl2LineConfProfModeSpecTable
- Siblings
- 12
Syntax
VDSL2-LINE-TC-MIBXdsl2LineClassMask
- Source
- VDSL2-LINE-TC-MIBXdsl2LineClassMask
- Base type
Enumeration
Values & Constraints
Type Values
1 | none |
2 | a998ORb997M1cORc998B |
3 | b997M1xOR998co |
4 | b997M2x |
5 | b998M1x |
6 | b998M2x |
7 | b998AdeM2x |
8 | bHpeM1 |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| xdsl2LConfProfXdslMode The DSL Mode is a way of categorizing the various xDSL
transmission modes into groups, each group (xDSL Mode) shares
the same PSD configuration.
There should be multiple entries i… | column | VDSL2-LINE-TC-MIBXdsl2OperationModes | .1.3.6.1.2.1.10.251.1.5.1.3.1.1 |
| xdsl2LConfProfLimitMask This configuration parameter contains the G.993.2 limit
PSD masks of the selected PSD mask class, enabled by the near-end
xTU on this line for each class of profiles.
This paramet… | column | VDSL2-LINE-TC-MIBXdsl2LineLimitMask | .1.3.6.1.2.1.10.251.1.5.1.3.1.11 |
| xdsl2LConfProfUs0Disable This configuration parameter indicates if the use of the US0 is
disabled for each limit PSD mask enabled in the
xdsl2LConfProfLimitMask parameter.
This parameter is defined per VD… | column | VDSL2-LINE-TC-MIBXdsl2LineUs0Disable | .1.3.6.1.2.1.10.251.1.5.1.3.1.12 |
| xdsl2LConfProfModeSpecRowStatus This object is used to create a new row or to modify or
delete an existing row in this table.
This row is activated by setting this object to 'active'.
… | column | SNMPv2-TCRowStatus | .1.3.6.1.2.1.10.251.1.5.1.3.1.13 |
| xdsl2LConfProfMaxNomPsdDs The maximum nominal transmit PSD in the downstream direction
during initialization and Showtime. It ranges from -600 to -300
units of 0.1 dBm/Hz (physical values are -60 to -30
d… | column | 0.1 dBm/Hz Integer32 | .1.3.6.1.2.1.10.251.1.5.1.3.1.2 |
| xdsl2LConfProfMaxNomPsdUs The maximum nominal transmit PSD in the upstream direction
during initialization and Showtime. It ranges from -600 to
-300 units of 0.1 dBm/Hz (physical values are -60 to -30
dBm… | column | 0.1 dBm/Hz Integer32 | .1.3.6.1.2.1.10.251.1.5.1.3.1.3 |
| xdsl2LConfProfMaxNomAtpDs The maximum nominal aggregate to transmit power in the
downstream direction during initialization and Showtime. It
ranges from 0 to 255 units of 0.1 dBm (physical values are 0
to… | column | 0.1 dBm Unsigned32 | .1.3.6.1.2.1.10.251.1.5.1.3.1.4 |
| xdsl2LConfProfMaxNomAtpUs The maximum nominal aggregate transmit power in the upstream
direction during initialization and Showtime. It ranges from
0 to 255 units of 0.1 dBm (physical values are 0 to 25.5… | column | 0.1 dBm Unsigned32 | .1.3.6.1.2.1.10.251.1.5.1.3.1.5 |
| xdsl2LConfProfMaxAggRxPwrUs The maximum upstream aggregate receive power over the
relevant set of subcarriers. The xTU-C should verify that the
upstream power cutback is such that this maximum aggregate
rec… | column | 0.1 dBm Integer32 | .1.3.6.1.2.1.10.251.1.5.1.3.1.6 |
| xdsl2LConfProfPsdMaskDs The downstream PSD mask applicable at the U-C2 reference
point.
This parameter is used only for G.992.5 and it may impose PSD
restrictions (breakpoints) in addition to the Limit P… | column | VDSL2-LINE-TC-MIBXdsl2PsdMaskDs | .1.3.6.1.2.1.10.251.1.5.1.3.1.7 |
| xdsl2LConfProfPsdMaskUs The upstream PSD mask applicable at the U-R2 reference
point.
This parameter is used only for G.992.5, and it may impose PSD
restrictions (breakpoints) in addition to the Limit PS… | column | VDSL2-LINE-TC-MIBXdsl2PsdMaskUs | .1.3.6.1.2.1.10.251.1.5.1.3.1.8 |
| xdsl2LConfProfPsdMaskSelectUs The selected upstream PSD mask. This parameter is used only
for Annexes J and M of G.992.3 and G.992.5, and the same
selection is used for all relevant enabled bits in
xdsl2LConf… | column | VDSL2-LINE-TC-MIBXdsl2LinePsdMaskSelectUs | .1.3.6.1.2.1.10.251.1.5.1.3.1.9 |