invControlInvSleepTime
USHA-MIB ·
.1.3.6.1.4.1.2468.1.6.1.1.5.2
Object
The time in minutes for the inverter to go to sleep when
instructed. When in sleep mode, the inverter will not provide
output power regardless of the input line state. Once the
specified time has elapsed, output power will be restored.
This is a configuration setting. The inverter will not go to
sleep until told to do so by the manager from a management
station.
Any input value is allowed, however the inverter only recognizes
0 - 9999 minutes in one minute increments.
If the provided value is higher than the highest acceptable
value, the highest acceptable value is used.
Context
- MIB
- USHA-MIB
- OID
.1.3.6.1.4.1.2468.1.6.1.1.5.2- Type
- scalar
- Access
- readwrite
- Status
- mandatory
- Parent
- invControlGroup
Net-SNMP examples
How SNMP and these commands workScalars have one instance, identified by the .0 suffix.
Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'USHA-MIB' -M '/opt/observium/mibs/ingrasys:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'USHA-MIB::invControlInvSleepTime.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'USHA-MIB' -M '/opt/observium/mibs/ingrasys:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'USHA-MIB::invControlInvSleepTime'
Syntax
- Source
- SNMPv2-SMIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647