USHA-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
9
Rows
9
Columns
76

invInputGroupTable

table mandatory
.1.3.6.1.4.1.2468.1.6.1.1.3.3 · 1 row entry · 7 columns
Uses the ingrasys variant from /opt/observium/mibs/ingrasys.
Command help
Walk invInputGroupTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'USHA-MIB' -M '/opt/observium/mibs/ingrasys:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'USHA-MIB::invInputGroupTable'
A list of input table entries.  The number of entries
is given by the value of invInputGroupNumLines.
invInputGroupEntry row .1.3.6.1.4.1.2468.1.6.1.1.3.3.1
An entry containing information applicable to a
particular input line.
Column Syntax OID
The index of InvInputGroupEntry.
UPS-MIBPositiveInteger
Constraints:
range: 0-65535
.1.3.6.1.4.1.2468.1.6.1.1.3.3.1.1
The present input frequency.
UPS-MIBNonNegativeInteger
Type Constraints:
range: 0..2147483647
.1.3.6.1.4.1.2468.1.6.1.1.3.3.1.2
The input utility line voltage in 0.1 volts.
UPS-MIBNonNegativeInteger
Type Constraints:
range: 0..2147483647
.1.3.6.1.4.1.2468.1.6.1.1.3.3.1.3
The magnitude of the present input current in 0.1 A.
UPS-MIBNonNegativeInteger
Type Constraints:
range: 0..2147483647
.1.3.6.1.4.1.2468.1.6.1.1.3.3.1.4
The magnitude of the present input true power.
UPS-MIBNonNegativeInteger
Type Constraints:
range: 0..2147483647
.1.3.6.1.4.1.2468.1.6.1.1.3.3.1.5
The maximum utility line voltage in 0.1 VAC for last 1 minute.
UPS-MIBNonNegativeInteger
Type Constraints:
range: 0..2147483647
.1.3.6.1.4.1.2468.1.6.1.1.3.3.1.6
The minimum utility line voltage in 0.1 VAC for last 1 minute.
UPS-MIBNonNegativeInteger
Type Constraints:
range: 0..2147483647
.1.3.6.1.4.1.2468.1.6.1.1.3.3.1.7

invOutputGroupTable

table mandatory
.1.3.6.1.4.1.2468.1.6.1.1.4.4 · 1 row entry · 5 columns
Uses the ingrasys variant from /opt/observium/mibs/ingrasys.
Command help
Walk invOutputGroupTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'USHA-MIB' -M '/opt/observium/mibs/ingrasys:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'USHA-MIB::invOutputGroupTable'
A list of output table entries.  The number of
entries is given by the value of invOutputGroupNumLines.
invOutputGroupEntry row .1.3.6.1.4.1.2468.1.6.1.1.4.4.1
An entry containing information applicable to a
particular output line.
Column Syntax OID
The output line identifier.
UPS-MIBPositiveInteger
Constraints:
range: 0-65535
.1.3.6.1.4.1.2468.1.6.1.1.4.4.1.1
The output voltage of the inverter system in 0.1 volts.
UPS-MIBNonNegativeInteger
Type Constraints:
range: 0..2147483647
.1.3.6.1.4.1.2468.1.6.1.1.4.4.1.2
The output current of the inverter system in 0.1 Amps.
UPS-MIBNonNegativeInteger
Type Constraints:
range: 0..2147483647
.1.3.6.1.4.1.2468.1.6.1.1.4.4.1.3
The present output true power.
UPS-MIBNonNegativeInteger
Type Constraints:
range: 0..2147483647
.1.3.6.1.4.1.2468.1.6.1.1.4.4.1.4
The percentage of the inverter power capacity presently
being used on this output line, i.e., the greater of
the percent load of true power capacity and the
percent load of VA.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2468.1.6.1.1.4.4.1.5
.1.3.6.1.4.1.2468.1.6.1.1.5.4 · 1 row entry · 5 columns
Uses the ingrasys variant from /opt/observium/mibs/ingrasys.
Command help
Walk invControlShutdownParametersTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'USHA-MIB' -M '/opt/observium/mibs/ingrasys:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'USHA-MIB::invControlShutdownParametersTable'
Table which describes the parametes for shutdown process
when shutdown event occurs
invControlShutdownParametersEntry row .1.3.6.1.4.1.2468.1.6.1.1.5.4.1
Indexes
Column Syntax OID
The shutdown event identification
Enumeration
Enumerated Values:
1acFail
2inverterLow
3invOverload
4invOverTempeature
5weeklySchedule
6specialDaySchedule
7emdTemperatureOverThreshold
8emdAlarm1
9emdAlarm2
.1.3.6.1.4.1.2468.1.6.1.1.5.4.1.1
Status of the corresponding shutdown Event.
When set to disable(), shutdown process will not start when
corresponding event occured.
Enumerationr/w
Enumerated Values:
1disable
2warning
3clientShutdown
4invTurnOff
.1.3.6.1.4.1.2468.1.6.1.1.5.4.1.2
The Delay after the occurance of the curresponding shutdown
event that USHA should issue shutdown request to
connected clients. For WeeklyScheduledShutdown and
SpecialScheduledShutdown, this is the time before the
confi…
Integer32r/w
Constraints:
range: 0-10080
.1.3.6.1.4.1.2468.1.6.1.1.5.4.1.3
The delay after the occurance of the curresponding shutdown
event that the USHA will start sending the warning
message to the connected clients. The value is in units of
seconds
Integer32r/w
Constraints:
range: 0-3600
.1.3.6.1.4.1.2468.1.6.1.1.5.4.1.4
The frequency of sending warning messages to the connected
clients when the curresponding shutdown event occurs.
The value is in units of seconds.
Integer32r/w
Constraints:
range: 0-3600
.1.3.6.1.4.1.2468.1.6.1.1.5.4.1.5
.1.3.6.1.4.1.2468.1.6.1.1.5.5 · 1 row entry · 5 columns
Uses the ingrasys variant from /opt/observium/mibs/ingrasys.
Command help
Walk invControlWeeklyScheduleTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'USHA-MIB' -M '/opt/observium/mibs/ingrasys:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'USHA-MIB::invControlWeeklyScheduleTable'
The table to schedule shutting down the inverter by weekly.
invControlWeeklyScheduleEntry row .1.3.6.1.4.1.2468.1.6.1.1.5.5.1
The entries for each day.
Column Syntax OID
The index of scheduled events.
Integer32
Constraints:
range: 0-65535
.1.3.6.1.4.1.2468.1.6.1.1.5.5.1.1
The weekday on which the inverter should shut down.
Enumerationr/w
Enumerated Values:
1sunday
2monday
3tuesday
4wednesday
5thursday
6friday
7saturday
8none
.1.3.6.1.4.1.2468.1.6.1.1.5.5.1.2
The time that the process of shutting down the inverter will be initiated
in hh:mm format.
RFC1213-MIBDisplayStringr/w
Constraints:
range: 5-5
.1.3.6.1.4.1.2468.1.6.1.1.5.5.1.3
The weekday on which the inverter should restart
Enumerationr/w
Enumerated Values:
1sunday
2monday
3tuesday
4wednesday
5thursday
6friday
7saturday
8none
.1.3.6.1.4.1.2468.1.6.1.1.5.5.1.4
The time the inverter will restart in hh:mm format.
RFC1213-MIBDisplayStringr/w
Constraints:
range: 5-5
.1.3.6.1.4.1.2468.1.6.1.1.5.5.1.5
.1.3.6.1.4.1.2468.1.6.1.1.5.6 · 1 row entry · 5 columns
Uses the ingrasys variant from /opt/observium/mibs/ingrasys.
Command help
Walk invControlSpecialScheduleTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'USHA-MIB' -M '/opt/observium/mibs/ingrasys:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'USHA-MIB::invControlSpecialScheduleTable'
The table to schedule shutting down the inverter.
invControlSpecialScheduleEntry row .1.3.6.1.4.1.2468.1.6.1.1.5.6.1
The entries for each day.
Column Syntax OID
The index of scheduled events.
Integer32
Constraints:
range: 0-65535
.1.3.6.1.4.1.2468.1.6.1.1.5.6.1.1
The date on which the inverter should shut down in dd/mm/yyyy
format.
RFC1213-MIBDisplayStringr/w
Constraints:
range: 10-10
.1.3.6.1.4.1.2468.1.6.1.1.5.6.1.2
The time that the process of shutting down the inverter will be initiated
in hh:mm format
RFC1213-MIBDisplayStringr/w
Constraints:
range: 5-5
.1.3.6.1.4.1.2468.1.6.1.1.5.6.1.3
The date on which the inverter should restart in dd/mm/yyyy format
RFC1213-MIBDisplayStringr/w
Constraints:
range: 10-10
.1.3.6.1.4.1.2468.1.6.1.1.5.6.1.4
The time the inverter will restart in hh:mm format.
RFC1213-MIBDisplayStringr/w
Constraints:
range: 5-5
.1.3.6.1.4.1.2468.1.6.1.1.5.6.1.5

invDevicesTable

table mandatory
.1.3.6.1.4.1.2468.1.6.1.1.7.2 · 1 row entry · 6 columns
Uses the ingrasys variant from /opt/observium/mibs/ingrasys.
Command help
Walk invDevicesTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'USHA-MIB' -M '/opt/observium/mibs/ingrasys:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'USHA-MIB::invDevicesTable'
The devices powered by INV and registered to USHA
invDevicesEntry row .1.3.6.1.4.1.2468.1.6.1.1.7.2.1
The devices protected by USHA
Indexes
Column Syntax OID
indexOfDevicemandatory
The index of the device that is plugged into the inverter.
UPS-MIBNonNegativeInteger
Type Constraints:
range: 0..2147483647
.1.3.6.1.4.1.2468.1.6.1.1.7.2.1.1
addrOfDevicemandatory
The ip address of the device.
RFC1155-SMIIpAddress
Type Constraints:
range: 4
.1.3.6.1.4.1.2468.1.6.1.1.7.2.1.2
nameOfDevicemandatory
The name/description of the device plugged into the inverter.
RFC1213-MIBDisplayString
Constraints:
range: 0-31
.1.3.6.1.4.1.2468.1.6.1.1.7.2.1.3
The device registered to USHA
RFC1213-MIBDisplayString .1.3.6.1.4.1.2468.1.6.1.1.7.2.1.4
The device registered time to USHA.
RFC1213-MIBDisplayString .1.3.6.1.4.1.2468.1.6.1.1.7.2.1.5
The device timeout counter. Unit: 10 seconds
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2468.1.6.1.1.7.2.1.6
.1.3.6.1.4.1.2468.1.6.1.1.8.18 · 1 row entry · 6 columns
Uses the ingrasys variant from /opt/observium/mibs/ingrasys.
Command help
Walk agentConfigTrapsReceiversTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'USHA-MIB' -M '/opt/observium/mibs/ingrasys:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'USHA-MIB::agentConfigTrapsReceiversTable'
A list of managers to send traps to.  The number of
entries is given by the value of agentConfigNumTrapReceivers
agentConfigTrapsReceiversEntry row .1.3.6.1.4.1.2468.1.6.1.1.8.18.1
The managers to send traps to.
Indexes
Column Syntax OID
trapsIndexmandatory
The index to a trap receiver entry.
Integer32
Constraints:
range: 0-65535
.1.3.6.1.4.1.2468.1.6.1.1.8.18.1.1
The IP address of the manager to send a trap to.
RFC1155-SMIIpAddressr/w
Type Constraints:
range: 4
.1.3.6.1.4.1.2468.1.6.1.1.8.18.1.2
The community name to use in the trap when
sent to the manager.
RFC1213-MIBDisplayStringr/w
Constraints:
range: 0-19
.1.3.6.1.4.1.2468.1.6.1.1.8.18.1.3
The trap group that NMS desired.
Enumerationr/w
Enumerated Values:
1none
2usha-trap
.1.3.6.1.4.1.2468.1.6.1.1.8.18.1.4
The severity level of traps to be received by this manager.
Enumerationr/w
Enumerated Values:
1informational
2warning
3severe
.1.3.6.1.4.1.2468.1.6.1.1.8.18.1.5
Description of trap receivers
RFC1213-MIBDisplayStringr/w
Constraints:
range: 0-31
.1.3.6.1.4.1.2468.1.6.1.1.8.18.1.6

envMonDevStatusTable

table mandatory
.1.3.6.1.4.1.2468.1.6.1.1.9.1 · 1 row entry · 10 columns
Uses the ingrasys variant from /opt/observium/mibs/ingrasys.
Command help
Walk envMonDevStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'USHA-MIB' -M '/opt/observium/mibs/ingrasys:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'USHA-MIB::envMonDevStatusTable'
A list to display status of EMD.
envMonDevStatus row .1.3.6.1.4.1.2468.1.6.1.1.9.1.1
A list to display status of EMD.
Column Syntax OID
The index to EMD status entry.
Integer32
Constraints:
range: 1-8
.1.3.6.1.4.1.2468.1.6.1.1.9.1.1.1
The device state of EMD.
Enumeration
Enumerated Values:
1unknow
2disabled
3emd31
.1.3.6.1.4.1.2468.1.6.1.1.9.1.1.2
The temperature of EMD.
degCEnumeration
Enumerated Values:
32768invalid
.1.3.6.1.4.1.2468.1.6.1.1.9.1.1.3
The humidity of EMD.
0.1%Enumeration
Enumerated Values:
32768invalid
.1.3.6.1.4.1.2468.1.6.1.1.9.1.1.4
The temperature status of EMD.
Enumeration
Enumerated Values:
1normal
2warning
3critical
.1.3.6.1.4.1.2468.1.6.1.1.9.1.1.5
The humidity status of EMD.
Enumeration
Enumerated Values:
1normal
2warning
3critical
.1.3.6.1.4.1.2468.1.6.1.1.9.1.1.6
The alarm-1 status of EMD.
Enumeration
Enumerated Values:
1disabled
2inactive
3active
.1.3.6.1.4.1.2468.1.6.1.1.9.1.1.7
The alarm-2 status of EMD.
Enumeration
Enumerated Values:
1disabled
2inactive
3active
.1.3.6.1.4.1.2468.1.6.1.1.9.1.1.8
The device modbus address of EMD.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2468.1.6.1.1.9.1.1.9
Description of EMD application FW version
RFC1213-MIBDisplayString
Constraints:
range: 0-12
.1.3.6.1.4.1.2468.1.6.1.1.9.1.1.10

envMonDevCfgTable

table mandatory
.1.3.6.1.4.1.2468.1.6.1.1.9.2 · 1 row entry · 27 columns
Uses the ingrasys variant from /opt/observium/mibs/ingrasys.
Command help
Walk envMonDevCfgTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'USHA-MIB' -M '/opt/observium/mibs/ingrasys:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'USHA-MIB::envMonDevCfgTable'
A list to display configure of EMD.
envMonDevCfg row .1.3.6.1.4.1.2468.1.6.1.1.9.2.1
A list to display configure of EMD.
Column Syntax OID
The index to EMD configure entry.
Integer32
Constraints:
range: 0-7
.1.3.6.1.4.1.2468.1.6.1.1.9.2.1.1
The index to EMD LT Close.
Enumerationr/w
Enumerated Values:
1disabled
2enabled
.1.3.6.1.4.1.2468.1.6.1.1.9.2.1.2
Description of EMD temperature sensor
RFC1213-MIBDisplayStringr/w
Constraints:
range: 0-31
.1.3.6.1.4.1.2468.1.6.1.1.9.2.1.3
Description of EMD temperature sensor
RFC1213-MIBDisplayStringr/w
Constraints:
range: 0-31
.1.3.6.1.4.1.2468.1.6.1.1.9.2.1.4
Description of EMD alarm-1 name
RFC1213-MIBDisplayStringr/w
Constraints:
range: 0-31
.1.3.6.1.4.1.2468.1.6.1.1.9.2.1.5
Description of EMD alarm-2 name
RFC1213-MIBDisplayStringr/w
Constraints:
range: 0-31
.1.3.6.1.4.1.2468.1.6.1.1.9.2.1.6
Description of EMD location name
RFC1213-MIBDisplayStringr/w
Constraints:
range: 0-15
.1.3.6.1.4.1.2468.1.6.1.1.9.2.1.7
To enable/disable high warning set point check with EMD temperature.
Enumerationr/w
Enumerated Values:
1disabled
2enabled
.1.3.6.1.4.1.2468.1.6.1.1.9.2.1.8
To enable/disable low warning set point check with EMD temperature.
Enumerationr/w
Enumerated Values:
1disabled
2enabled
.1.3.6.1.4.1.2468.1.6.1.1.9.2.1.9
To enable/disable high critical set point check with EMD temperature.
Enumerationr/w
Enumerated Values:
1disabled
2enabled
.1.3.6.1.4.1.2468.1.6.1.1.9.2.1.10
To enable/disable low critical set point check with EMD temperature.
Enumerationr/w
Enumerated Values:
1disabled
2enabled
.1.3.6.1.4.1.2468.1.6.1.1.9.2.1.11
The high warning threshold of temperature of EMD.
degCInteger32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2468.1.6.1.1.9.2.1.12
The low warning threshold of temperature of EMD.
degCInteger32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2468.1.6.1.1.9.2.1.13
The high critical threshold of temperature of EMD.
degCInteger32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2468.1.6.1.1.9.2.1.14
The low critical threshold of temperature of EMD.
degCInteger32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2468.1.6.1.1.9.2.1.15
The offset index of temperature of EMD.
degCEnumerationr/w
Enumerated Values:
1temperatueUnoffset
2temperatueIncrease0Point5
3temperatueIncrease1Point0
4temperatueIncrease1Point5
5temperatueIncrease2Point0
6temperatueIncrease2Point5
7temperatueIncrease3Point0
8temperatueDecrease0Point5
9temperatueDecrease1Point0
10temperatueDecrease1Point5
11temperatueDecrease2Point0
12temperatueDecrease2Point5
13temperatueDecrease3Point0
.1.3.6.1.4.1.2468.1.6.1.1.9.2.1.16
To enable/disable high warning set point check with EMD humidity.
Enumerationr/w
Enumerated Values:
1disabled
2enabled
.1.3.6.1.4.1.2468.1.6.1.1.9.2.1.17
To enable/disable low warning set point check with EMD humidity.
Enumerationr/w
Enumerated Values:
1disabled
2enabled
.1.3.6.1.4.1.2468.1.6.1.1.9.2.1.18
To enable/disable high critical set point check with EMD humidity.
Enumerationr/w
Enumerated Values:
1disabled
2enabled
.1.3.6.1.4.1.2468.1.6.1.1.9.2.1.19
To enable/disable low critical set point check with EMD humidity.
Enumerationr/w
Enumerated Values:
1disabled
2enabled
.1.3.6.1.4.1.2468.1.6.1.1.9.2.1.20
The high warning threshold of humidity of EMD.
0.1%Integer32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2468.1.6.1.1.9.2.1.21
The low warning threshold of humidity of EMD.
0.1%Integer32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2468.1.6.1.1.9.2.1.22
The high critical threshold of humidity of EMD.
0.1%Integer32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2468.1.6.1.1.9.2.1.23
The low critical threshold of humidity of EMD.
0.1%Integer32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2468.1.6.1.1.9.2.1.24
The offset index of humidity of EMD.
%Enumerationr/w
Enumerated Values:
1humidityUnoffset
2humidityIncrease1Point0
3humidityIncrease2Point0
4humidityIncrease3Point0
5humidityIncrease4Point0
6humidityIncrease5Point0
7humidityIncrease6Point0
8humidityDecrease1Point0
9humidityDecrease2Point0
10humidityDecrease3Point0
11humidityDecrease4Point0
12humidityDecrease5Point0
13humidityDecrease6Point0
.1.3.6.1.4.1.2468.1.6.1.1.9.2.1.25
The alarm-1 setup of EMD.
Enumerationr/w
Enumerated Values:
1disabled
2no
3nc
.1.3.6.1.4.1.2468.1.6.1.1.9.2.1.26
The alarm-2 setup of EMD.
Enumerationr/w
Enumerated Values:
1disabled
2no
3nc
.1.3.6.1.4.1.2468.1.6.1.1.9.2.1.27