tmnxPtpTimeInfoOffsetFromMaster
TIMETRA-PTP-MIB ·
.1.3.6.1.4.1.6527.3.1.2.74.3.5.6
Object
scalar TmnxPtpTimeInterval
The value of tmnxPtpTimeInfoOffsetFromMaster indicates the current
offset of the local PTP clock from the parent PTP clock, calculated by
the local clock, as per IEEE Std 1588-2008, section 11.2.
It represents the 'instantaneous' value of calculated time offset
from the parent PTP clock, using timestamp information from the most
recent exchange of sync and delay request/response messages. There is
no filtering applied to the received sync and delay response messages,
and there is no averaging of this calculation over multiple exchanges
of sync and delay request/response messages.
The time that this offset was last calculated is provided in
tmnxPtpTimeInfoLastCalc.
The active CPM calculates this offset each time the local PTP clock and
the parent PTP clock exchange sync, delay request, and delay response
messages. The standby CPM does not calculate this offset, returning a
value of 0 for tmnxPtpTimeInfoOffsetFromMaster.
If PTP sync and delay request packets have not yet been exchanged
between the local clock and the parent clock, both
tmnxPtpTimeInfoOffsetFromMaster and tmnxPtpTimeInfoLastCalc return a
value of 0.
Due to asymmetry in the latencies experienced by PTP sync and delay
request packets, the calculated offset from master may not be a true
indication of the actual offset of the local clock from the
master/parent clock. As well, due to packet delay variation in the PTP
sync and delay request flows, there may be significant variation
between successive calculated values of
tmnxPtpTimeInfoOffsetFromMaster.
The system does not calculate the time offset between the local clock
and the parent PTP clock when tmnxPtpClockProfile is 'g8265dot1-2010
(1)'.
This corresponds to the 'currentDS.offsetFromMaster' data set member
defined in IEEE Std 1588-2008.
This object is now deprecated and replaced with
tmnxPtpTimeInfoOffFromMasterNs
Context
- MIB
- TIMETRA-PTP-MIB
- OID
.1.3.6.1.4.1.6527.3.1.2.74.3.5.6- Type
- scalar
- Access
- readonly
- Status
- current
- Parent
- tmnxPtpTimeInformation
- Groups
- 1
Net-SNMP examples
How SNMP and these commands workScalars have one instance, identified by the .0 suffix.
Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'TIMETRA-PTP-MIB' -M '/opt/observium/mibs/nokia:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'TIMETRA-PTP-MIB::tmnxPtpTimeInfoOffsetFromMaster.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'TIMETRA-PTP-MIB' -M '/opt/observium/mibs/nokia:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'TIMETRA-PTP-MIB::tmnxPtpTimeInfoOffsetFromMaster'
Syntax
- Source
- TmnxPtpTimeInterval
- Base type
OctetString
Type Description
TmnxPtpTimeInterval is an octet string encoding a signed time interval,
in scaled nanoseconds. The signed time interval is encoded as a 64-bit
two's complement integer, in network byte order. The time interval in
nanoseconds may be obtained by dividing the value by 2^16.
This object is used for items of data type 'TimeInterval' in IEEE
1588-2008.
Values & Constraints
Type Constraints
range: 8
Conformance
Member of