tmnxPtpPortLocalPortNumber
TIMETRA-PTP-MIB ·
.1.3.6.1.4.1.6527.3.1.2.74.3.6.1.1
Object
column TmnxPtpPortNumber
The value of tmnxPtpPortLocalPortNumber indicates the PTP port number
assigned by the local clock and used when communicating directly over
the Ethernet physical port corresponding to this table row.
If tmnxPtpClockClockType is either 'ordinarySlave (1)' or
'ordinaryMaster (2)', tmnxPtpPortLocalPortNumber has a value of 1.
The value of this object corresponds to the
portDS.portIdentity.portNumber data set member defined in IEEE Std
1588-2008.
Context
- MIB
- TIMETRA-PTP-MIB
- OID
.1.3.6.1.4.1.6527.3.1.2.74.3.6.1.1- Type
- column
- Access
- readonly
- Status
- current
- Parent
- tmnxPtpPortStatusEntry
- Groups
- 1
Net-SNMP examples
How SNMP and these commands workWalk the column to discover its indexed instances, or supply every index to read one instance.
Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'TIMETRA-PTP-MIB' -M '/opt/observium/mibs/nokia:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'TIMETRA-PTP-MIB::tmnxPtpPortLocalPortNumber'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'TIMETRA-PTP-MIB' -M '/opt/observium/mibs/nokia:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'TIMETRA-PTP-MIB::tmnxPtpPortLocalPortNumber.<index>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'TIMETRA-PTP-MIB' -M '/opt/observium/mibs/nokia:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'TIMETRA-PTP-MIB::tmnxPtpPortLocalPortNumber'
Syntax
- Source
- TmnxPtpPortNumber
- Base type
Unsigned32
Values & Constraints
Type Constraints
range: 0..65534
Conformance
Member of