tmnxPtpClockTxWhileSyncUncertain

TIMETRA-PTP-MIB · .1.3.6.1.4.1.6527.3.1.2.74.2.1.13

Object

scalar r/w SNMPv2-TCTruthValue
The value of tmnxPtpClockTxWhileSyncUncertain specifies whether the
PTP clock will transmit packets on PTP ports in the master state, even
if the local clock is uncertain that it is synchronized to a valid
timing source.

Context

MIB
TIMETRA-PTP-MIB
OID
.1.3.6.1.4.1.6527.3.1.2.74.2.1.13
Type
scalar
Access
readwrite
Status
current
Default
true
Parent
tmnxPtpClockConfig
Groups
1

Scalars have one instance, identified by the .0 suffix.

Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'TIMETRA-PTP-MIB' -M '/opt/observium/mibs/nokia:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'TIMETRA-PTP-MIB::tmnxPtpClockTxWhileSyncUncertain.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'TIMETRA-PTP-MIB' -M '/opt/observium/mibs/nokia:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'TIMETRA-PTP-MIB::tmnxPtpClockTxWhileSyncUncertain'

Syntax

Source
SNMPv2-TCTruthValue
Base type
Enumeration
Type Description
Represents a boolean value.

Values & Constraints

Type Values
1true
2false

Conformance