tmnxPtpClockTimeInaccuracy
TIMETRA-PTP-MIB ·
.1.3.6.1.4.1.6527.3.1.2.74.2.1.14
Object
scalar r/w
nanosecondsUnsigned32
The value of tmnxPtpClockTimeInaccuracy overrides the pre-set
time-inaccuracy value of the clock
This configuration can be used to override the system-generated value
for time-inaccuracy to the desired value. This is applicable only to
the c37dot238-2017 profile. The mandatory IEEE_C37_238 TLV in this
profile includes 'total time inaccuracy'. The value configured is
added to the parent clock's 'total time inaccuracy' for TLVs to
downstream clocks.
The value 0 indicates that the system-generated value is used.
Context
- MIB
- TIMETRA-PTP-MIB
- OID
.1.3.6.1.4.1.6527.3.1.2.74.2.1.14- Type
- scalar
- Access
- readwrite
- Status
- current
- Units
- nanoseconds
- Default
0- Parent
- tmnxPtpClockConfig
- Groups
- 1
Net-SNMP examples
How SNMP and these commands workScalars have one instance, identified by the .0 suffix.
Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'TIMETRA-PTP-MIB' -M '/opt/observium/mibs/nokia:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'TIMETRA-PTP-MIB::tmnxPtpClockTimeInaccuracy.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'TIMETRA-PTP-MIB' -M '/opt/observium/mibs/nokia:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'TIMETRA-PTP-MIB::tmnxPtpClockTimeInaccuracy'
Syntax
nanosecondsUnsigned32
Values & Constraints
Object Constraints
range: 0-10000000
Conformance
Member of