tmnxPtpClockRecStatsTimeInitial

TIMETRA-PTP-MIB · .1.3.6.1.4.1.6527.3.1.2.74.5.3.14

Object

scalar secondsSNMPv2-SMICounter32
The value of tmnxPtpClockRecStatsTimeInitial indicates the number of
seconds that the time recovery system has been active but has not yet
chosen a parent clock.

Context

MIB
TIMETRA-PTP-MIB
OID
.1.3.6.1.4.1.6527.3.1.2.74.5.3.14
Type
scalar
Access
readonly
Status
current
Units
seconds
Parent
tmnxPtpClockRecoveryStatistics
Groups
1

Scalars have one instance, identified by the .0 suffix.

Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'TIMETRA-PTP-MIB' -M '/opt/observium/mibs/nokia:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'TIMETRA-PTP-MIB::tmnxPtpClockRecStatsTimeInitial.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'TIMETRA-PTP-MIB' -M '/opt/observium/mibs/nokia:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'TIMETRA-PTP-MIB::tmnxPtpClockRecStatsTimeInitial'

Syntax

Source
SNMPv2-SMICounter32
Base type
Unsigned32

Values & Constraints

Type Constraints
range: 0..4294967295

Conformance