tmnxPtpClockPriority1
TIMETRA-PTP-MIB ·
.1.3.6.1.4.1.6527.3.1.2.74.2.1.6
Object
The value of tmnxPtpClockPriority1 specifies the value of the
defaultDS.priority1 data set member defined in IEEE Std 1588-2008.
If tmnxPtpClockProfile is 'g8275dot1-2014 (3)', tmnxPtpClockPriority1
is set to a value of 128, and cannot be changed.
Context
- MIB
- TIMETRA-PTP-MIB
- OID
.1.3.6.1.4.1.6527.3.1.2.74.2.1.6- Type
- scalar
- Access
- readwrite
- Status
- current
- Default
128- Parent
- tmnxPtpClockConfig
- Groups
- 1
Net-SNMP examples
How SNMP and these commands workScalars have one instance, identified by the .0 suffix.
Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'TIMETRA-PTP-MIB' -M '/opt/observium/mibs/nokia:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'TIMETRA-PTP-MIB::tmnxPtpClockPriority1.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'TIMETRA-PTP-MIB' -M '/opt/observium/mibs/nokia:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'TIMETRA-PTP-MIB::tmnxPtpClockPriority1'
Syntax
- Source
- TmnxPtpPriority
- Base type
Unsigned32
Type Description
The Precision Time Protocol (PTP) priority used both for the value to
advertise in the Announce messages and for the local clock value in
data set comparisons.
It is used by the Best Master Clock Algorithm to determine which clock
should provide timing for the network.
The priority is rated highest (0) to lowest (255).
Values & Constraints
Type Constraints
range: 0..255
Conformance
Member of