tmnxPtpClockLocalPriority
TIMETRA-PTP-MIB ·
.1.3.6.1.4.1.6527.3.1.2.74.2.1.11
Object
The value of tmnxPtpClockLocalPriority specifies the local priority
used in the best master clock algorithm for the PTP clock when
tmnxPtpClockProfile is 'g8275dot1-2014 (3)'.
This value is not applicable when tmnxPtpClockProfile is configured to
some other value, and cannot be configured.
This object corresponds to the defaultDS.localPriority data set member
defined in ITU-T G.8275.1.
Context
- MIB
- TIMETRA-PTP-MIB
- OID
.1.3.6.1.4.1.6527.3.1.2.74.2.1.11- Type
- scalar
- Access
- readwrite
- Status
- current
- Default
128- Parent
- tmnxPtpClockConfig
- Groups
- 1
Net-SNMP examples
How SNMP and these commands workScalars have one instance, identified by the .0 suffix.
Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'TIMETRA-PTP-MIB' -M '/opt/observium/mibs/nokia:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'TIMETRA-PTP-MIB::tmnxPtpClockLocalPriority.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'TIMETRA-PTP-MIB' -M '/opt/observium/mibs/nokia:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'TIMETRA-PTP-MIB::tmnxPtpClockLocalPriority'
Syntax
- Source
- TmnxPtpPriority
- Base type
Unsigned32
Type Description
The Precision Time Protocol (PTP) priority used both for the value to
advertise in the Announce messages and for the local clock value in
data set comparisons.
It is used by the Best Master Clock Algorithm to determine which clock
should provide timing for the network.
The priority is rated highest (0) to lowest (255).
Values & Constraints
Object Constraints
range: 1-255
Type Constraints
range: 0..255
Conformance
Member of