tmnxPtpClockLocalPriority

TIMETRA-PTP-MIB · .1.3.6.1.4.1.6527.3.1.2.74.2.1.11

Object

scalar r/w TmnxPtpPriority
The value of tmnxPtpClockLocalPriority specifies the local priority
used in the best master clock algorithm for the PTP clock when
tmnxPtpClockProfile is 'g8275dot1-2014 (3)'.
          
This value is not applicable when tmnxPtpClockProfile is configured to
some other value, and cannot be configured.
          
This object corresponds to the defaultDS.localPriority data set member
defined in ITU-T G.8275.1.

Context

MIB
TIMETRA-PTP-MIB
OID
.1.3.6.1.4.1.6527.3.1.2.74.2.1.11
Type
scalar
Access
readwrite
Status
current
Default
128
Parent
tmnxPtpClockConfig
Groups
1

Scalars have one instance, identified by the .0 suffix.

Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'TIMETRA-PTP-MIB' -M '/opt/observium/mibs/nokia:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'TIMETRA-PTP-MIB::tmnxPtpClockLocalPriority.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'TIMETRA-PTP-MIB' -M '/opt/observium/mibs/nokia:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'TIMETRA-PTP-MIB::tmnxPtpClockLocalPriority'

Syntax

Source
TmnxPtpPriority
Base type
Unsigned32
Type Description
The Precision Time Protocol (PTP) priority used both for the value to
advertise in the Announce messages and for the local clock value in
data set comparisons.
          
It is used by the Best Master Clock Algorithm to determine which clock
should provide timing for the network.
          
The priority is rated highest (0) to lowest (255).

Values & Constraints

Object Constraints
range: 1-255
Type Constraints
range: 0..255

Conformance