tmnxPtpClockDomain
TIMETRA-PTP-MIB ·
.1.3.6.1.4.1.6527.3.1.2.74.2.1.4
Object
The value of tmnxPtpClockDomain specifies the domain in which PTP 1588
runs on the system.
The default value of tmnxPtpClockDomain depends on the value of
tmnxPtpClockProfile. If tmnxPtpClockProfile is 'g8265dot1-2010 (1)',
the default value is 4. If tmnxPtpClockProfile is 'ieee1588-2008 (2)',
the default value is 0. If tmnxPtpClockProfile is
'g8275dot1-2014 (3)', the default value is 24.
If tmnxPtpClockProfile is 'g8275dot1-2014 (3)', tmnxPtpClockDomain may
only be set to a value in the range 24-43.
This object can only be modified if tmnxPtpClockAdminState is set to
'outOfService (3)', otherwise an 'inconsistentValue' error is
returned.
Context
- MIB
- TIMETRA-PTP-MIB
- OID
.1.3.6.1.4.1.6527.3.1.2.74.2.1.4- Type
- scalar
- Access
- readwrite
- Status
- current
- Parent
- tmnxPtpClockConfig
- Groups
- 1
Net-SNMP examples
How SNMP and these commands workScalars have one instance, identified by the .0 suffix.
Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'TIMETRA-PTP-MIB' -M '/opt/observium/mibs/nokia:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'TIMETRA-PTP-MIB::tmnxPtpClockDomain.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'TIMETRA-PTP-MIB' -M '/opt/observium/mibs/nokia:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'TIMETRA-PTP-MIB::tmnxPtpClockDomain'
Syntax
- Source
- TmnxPtpDomain
- Base type
Unsigned32
Values & Constraints
Type Constraints
range: 0..255
Conformance
Member of