pwEnetPwIfIndex

PW-ENET-STD-MIB · .1.3.6.1.2.1.180.1.1.1.6

Object

If the PW is modeled as an ifIndex in the ifTable, this
object indicates the value of the ifIndex representing the
Ethernet PW on the PSN side in the Etherlike-MIB.  Note that
this value may be different from the value of pwIfIndex
that represents the ifIndex of the PW for ifType 'pw'.

Context

MIB
PW-ENET-STD-MIB
OID
.1.3.6.1.2.1.180.1.1.1.6
Type
column
Access
readwrite
Status
current
Parent
pwEnetEntry
Groups
1

Walk the column to discover its indexed instances, or supply every index to read one instance.

Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PW-ENET-STD-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PW-ENET-STD-MIB::pwEnetPwIfIndex'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'PW-ENET-STD-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PW-ENET-STD-MIB::pwEnetPwIfIndex.<pwIndex>.<pwEnetPwInstance>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'PW-ENET-STD-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'PW-ENET-STD-MIB::pwEnetPwIfIndex'

Syntax

Source
IF-MIBInterfaceIndexOrZero
Base type
Integer32
Display format
d
Type Description
This textual convention is an extension of the
InterfaceIndex convention.  The latter defines a greater
than zero value used to identify an interface or interface
sub-layer in the managed system.  This extension permits the
additional value of zero.  the value zero is object-specific
and must therefore be defined as part of the description of
any object which uses this syntax.  Examples of the usage of
zero might include situations where interface was unknown,
or when none or all interfaces need to be referenced.

Values & Constraints

Type Constraints
range: 0..2147483647

Conformance

Member of
Compliance refinements
Write access and values other than zero are
required only for implementations that support
modeling the Ethernet PW in the Etherlike-MIB.
Write access is not required. Values other than
zero are required only for implementations that
support modeling the Ethernet PW in the
Etherlike-MIB.