eoACPwrAttributesWyePhaseEntry
POWER-ATTRIBUTES-MIB ·
.1.3.6.1.2.1.230.1.3.1
Object
row
This table describes measurements of a phase in a WYE
three-phase power system. Three entries are required for
each supported entPhysicalIndex entry. Voltage
measurements are relative to neutral.
Each entry describes power attributes of one phase of a
WYE three-phase power system.
Context
- MIB
- POWER-ATTRIBUTES-MIB
- OID
.1.3.6.1.2.1.230.1.3.1- Type
- row
- Status
- current
- Parent
- eoACPwrAttributesWyePhaseTable
- Table
- eoACPwrAttributesWyePhaseTable
- Children
- 9
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| eoACPwrAttributesWyePhaseIndex A phase angle typically corresponding to 0, 120, 240. | column | Integer32 | .1.3.6.1.2.1.230.1.3.1.1 |
| eoACPwrAttributesWyePhaseToNeutralVoltage A measured value of phase to neutral voltage. IEC
61850-7-4 attribute 'PNV'. | column | 0.1 Volt AC SNMPv2-SMIInteger32 | .1.3.6.1.2.1.230.1.3.1.2 |
| eoACPwrAttributesWyeCurrent A measured value of phase currents. IEC 61850-7-4
attribute 'A'. | column | 0.1 amperes AC SNMPv2-SMIInteger32 | .1.3.6.1.2.1.230.1.3.1.3 |
| eoACPwrAttributesWyeActivePower A measured value of the actual power delivered to or
consumed by the load with the magnitude indicated
separately in eoPowerUnitMultiplier. IEC 61850-7-4
attribute 'W'. | column | watts SNMPv2-SMIInteger32 | .1.3.6.1.2.1.230.1.3.1.4 |
| eoACPwrAttributesWyeReactivePower A measured value of the reactive portion of the apparent
power with the magnitude of indicated separately in
eoPowerUnitMultiplier. IEC 61850-7-4 attribute 'VAr'. | column | volt-amperes reactive SNMPv2-SMIInteger32 | .1.3.6.1.2.1.230.1.3.1.5 |
| eoACPwrAttributesWyeApparentPower A measured value of the voltage and current determines
the apparent power with the indicated separately in
eoPowerUnitMultiplier. Active plus reactive power equals
the total appa… | column | volt-amperes SNMPv2-SMIInteger32 | .1.3.6.1.2.1.230.1.3.1.6 |
| eoACPwrAttributesWyePowerFactor A measured value ratio of the real power flowing to the
load versus the apparent power for this phase. IEC
61850-7-4 attribute 'PF'. Power Factor can be positive or
negative whe… | column | hundredths Integer32 | .1.3.6.1.2.1.230.1.3.1.7 |
| eoACPwrAttributesWyeThdCurrent A calculated value for the voltage total harmonic
distortion (THD) for phase to phase. Method of
calculation is not specified.
IEC 61850-7-4 attribute 'ThdA'. | column | hundredths of percent Integer32 | .1.3.6.1.2.1.230.1.3.1.8 |
| eoACPwrAttributesWyeThdPhaseToNeutralVoltage A calculated value of the voltage total harmonic
distortion (THD) for phase to neutral. IEC 61850-7-4
attribute 'ThdPhV'. | column | hundredths of percent Integer32 | .1.3.6.1.2.1.230.1.3.1.9 |
Indexes
| Object | Type | Syntax | OID |
|---|---|---|---|
| ENTITY-MIBentPhysicalIndex The index for this entry. | column | PhysicalIndex | .1.3.6.1.2.1.47.1.1.1.1.1 |
| eoACPwrAttributesWyePhaseIndex A phase angle typically corresponding to 0, 120, 240. | column | Integer32 | .1.3.6.1.2.1.230.1.3.1.1 |