hwMplsResourceType
HUAWEI-MPLS-EXTEND-MIB ·
.1.3.6.1.4.1.2011.5.25.121.2.2.11
Object
scalar
Enumeration
The value of this object identifies that the number of MPLS resources has exceeded the threshold or the maximum number. Options: 1.autoBypassTunnelIf(1) -Indicates that the resource is auto bypass tunnel interface. 2.p2mpAutoTunnelIf(2) -Indicates that the resource is P2MP auto tunnel interface. 3.teBfd(3) -Indicates that the resource is dynamic BFD for TE LSP. 4.ldpBfd(4) -Indicates that the resource is dynamic BFD for LDP LSP. 5.mldpTotalTree(5) -Indicates that the resource is the total number of MLDP trees. 6.mldpTotalBranch(6) -Indicates that the resource is the total number of MLDP branches. 7.ldpTotalRemoteAdjacency(7) -Indicates that the resource is LDP total remote adjacency. 8.outSegment(8) -Indicates that the resource is LDP outSegment. 9.autoPrimaryTunnelIf(9) -Indicates that the resource is auto primary tunnel interface. 10.ldpTotalLocalAdjacency(10) -Indicates that the resource is LDP total local adjacency. 11.cspfNode(11) -Indicates that the resource is cspf node. 12.cspfLink(12) -Indicates that the resource is cspf link. 13.cspfNlsa(13) -Indicates that the resource is cspf nlsa. 14.cspfSrlg(14) -Indicates that the resource is cspf srlg. 15.rsvpLsp(15) -Indicates that the resource is rsvp lsp. 16.unknown(100) -Indicates that the resource type is unknown.
Context
- MIB
- HUAWEI-MPLS-EXTEND-MIB
- OID
.1.3.6.1.4.1.2011.5.25.121.2.2.11- Type
- scalar
- Access
- notifyonly
- Status
- current
- Parent
- hwMplsTrapObjects
- Siblings
- 23
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | autoBypassTunnelIf |
2 | p2mpAutoTunnelIf |
3 | teBfd |
4 | ldpBfd |
5 | mldpTotalTree |
6 | mldpTotalBranch |
7 | ldpTotalRemoteAdjacency |
8 | outSegment |
9 | autoPrimaryTunnelIf |
10 | ldpTotalLocalAdjacency |
11 | cspfNode |
12 | cspfLink |
13 | cspfNlsa |
14 | cspfSrlg |
15 | rsvpLsp |
100 | unknown |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| hwMplsTunnelIfName obsolete The Tunnel Interface name. | scalar | SNMP-FRAMEWORK-MIBSnmpAdminString | .1.3.6.1.4.1.2011.5.25.121.2.2.1 |
| hwMplsTunnelDownIfIpAddrType The value of this object identifies the IP address type of the error interface on a tunnel. | scalar | INET-ADDRESS-MIBInetAddressType | .1.3.6.1.4.1.2011.5.25.121.2.2.10 |
| hwMplsResourceCurrentCount The value of this object identifies the number of the resources. | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.5.25.121.2.2.12 |
| hwMplsResourceThreshold The value of this object identifies the threshold for the number of the resources. | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.5.25.121.2.2.13 |
| hwMplsResourceTotalCount The value of this object identifies the maximum number of allowed resources. | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.5.25.121.2.2.14 |
| hwMplsSessionTunnelId The value of this object identifies the Tunnel ID. | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.5.25.121.2.2.15 |
| hwMplsLocalLspId The value of this object identifies the LSP ID. | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.5.25.121.2.2.16 |
| hwMplsIngressLsrId The value of this object identifies the ingress LSR ID. | scalar | MPLS-TC-STD-MIBMplsLsrIdentifier | .1.3.6.1.4.1.2011.5.25.121.2.2.17 |
| hwMplsEgressLsrId The value of this object identifies the egress LSR ID. | scalar | MPLS-TC-STD-MIBMplsLsrIdentifier | .1.3.6.1.4.1.2011.5.25.121.2.2.18 |
| hwMplsLspName This object indicates the name of an bidirectional static CR-LSP. | scalar | SNMP-FRAMEWORK-MIBSnmpAdminString | .1.3.6.1.4.1.2011.5.25.121.2.2.19 |
| hwMplsTunnelFrrConfigOper obsolete The value of this object identifies the operation that an FRR configuration is committed on the tunnel.
Options:
1.unconfig(… | scalar | Enumeration | .1.3.6.1.4.1.2011.5.25.121.2.2.2 |
| hwMplsP2mpId Indicates the P2MP id | scalar | INET-ADDRESS-MIBInetAddress | .1.3.6.1.4.1.2011.5.25.121.2.2.20 |
| hwMplsFeatureName The value of this object identifies the feature name.
Options:
1.ldp(1) -Indicates that the feature name is ldp.
2.t… | scalar | Enumeration | .1.3.6.1.4.1.2011.5.25.121.2.2.21 |
| hwMplsAlgorithmName The value of this object identifies the algorithm name.
Options:
1.md5(1) -Indicates that the algorithm name is md5.… | scalar | Enumeration | .1.3.6.1.4.1.2011.5.25.121.2.2.22 |
| hwMplsSlot Slot ID of an interface board. | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.5.25.121.2.2.23 |
| hwMplsChassis Chassis ID of an interface board. | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.5.25.121.2.2.24 |
| hwMplsTunnelDownReason Indicates the alarm reason as below:
Options:
1.other(1) -indicates that another cause was involved.
2.staticLspDown(2) -indicates that Static LSP down.
3.staticCr… | scalar | Enumeration | .1.3.6.1.4.1.2011.5.25.121.2.2.3 |
| hwMplsLspProtocol The value of this object identifies the protocol of the lsp which exceeds the threshold or total count.
Options:
1.ldp(1) … | scalar | Enumeration | .1.3.6.1.4.1.2011.5.25.121.2.2.4 |
| hwMplsLspThreshold The value of this object identifies the threshold of the lsp. | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.5.25.121.2.2.5 |
| hwMplsLspTotalCount The value of this object identifies the total permit count of lsp. | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.5.25.121.2.2.6 |
| hwMplsLspCurrentCount The value of this object identifies the current count of the lsp. | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.5.25.121.2.2.7 |
| hwMplsTunnelDownLSRID The value of this object identifies the LSR ID of the error node on a tunnel. | scalar | MPLS-TC-STD-MIBMplsLsrIdentifier | .1.3.6.1.4.1.2011.5.25.121.2.2.8 |
| hwMplsTunnelDownIfIpAddr The value of this object identifies the IP address of the error interface on a tunnel. | scalar | INET-ADDRESS-MIBInetAddress | .1.3.6.1.4.1.2011.5.25.121.2.2.9 |