eriRouterOpticalTransceiverMaxAlarmValue

ERICSSON-ROUTER-OPTICAL-TRANSCEIVER-MIB · .1.3.6.1.4.1.193.218.2.50.1.2.1.4

Object

The alarm high threshold value of tx power, rx power,
temperature, bias current and Vcc

Context

MIB
ERICSSON-ROUTER-OPTICAL-TRANSCEIVER-MIB
OID
.1.3.6.1.4.1.193.218.2.50.1.2.1.4
Type
column
Access
readonly
Status
current
Parent
eriRouterOpticalTransceiverParamEntry

Walk the column to discover its indexed instances, or supply every index to read one instance.

Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ERICSSON-ROUTER-OPTICAL-TRANSCEIVER-MIB' -M '/opt/observium/mibs/ericsson:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ERICSSON-ROUTER-OPTICAL-TRANSCEIVER-MIB::eriRouterOpticalTransceiverMaxAlarmValue'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'ERICSSON-ROUTER-OPTICAL-TRANSCEIVER-MIB' -M '/opt/observium/mibs/ericsson:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ERICSSON-ROUTER-OPTICAL-TRANSCEIVER-MIB::eriRouterOpticalTransceiverMaxAlarmValue.<ifIndex>.<eriRouterOpticalTransceiverParamType>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'ERICSSON-ROUTER-OPTICAL-TRANSCEIVER-MIB' -M '/opt/observium/mibs/ericsson:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'ERICSSON-ROUTER-OPTICAL-TRANSCEIVER-MIB::eriRouterOpticalTransceiverMaxAlarmValue'

Syntax

Source
EriRouterOpticalTransceiverParameterValue
Base type
Integer32
Display format
d-3
Type Description
Tx power value or threshold value     - unit milli dbm
Rx power value or threshold value     - unit milli dbm
temperature value or threshold value  - Represents a temperature,
              in degrees Celsius (0..(100.000))
Bias Current value or threshold value - unit 100s of microamperes
Vcc value or threshold value in millivolts
AUX1 if measured will be one of the following
     APD Bias Voltage value or threshold value
     TEC Current value or threshold value
     Laser Temperature value or threshold value
     Laser Wavelength value or threshold value
     Supply voltage options (+5V or +3.3V or + 1.8V or -5.2V)
		value or threshold value
     Supply current options (+5V or +3.3V or + 1.8V or -5.2V)
		value or threshold value
     Reserved
AUX2 if measured will be one of the following
     APD Bias Voltage value or threshold value
     TEC Current value or threshold value
     Laser Temperature value or threshold value
     Laser Wavelength value or threshold value
     Supply voltage options (+5V or +3.3V or + 1.8V or -5.2V)
		value or threshold value
     Supply current options (+5V or +3.3V or + 1.8V or -5.2V)
		value or threshold value
     Reserved

Values & Constraints

Type Constraints
range: -1000000..1000000