ERICSSON-ROUTER-OPTICAL-TRANSCEIVER-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
3
Rows
3
Columns
34
.1.3.6.1.4.1.193.218.2.50.1.1 · 1 row entry · 20 columns
Uses the ericsson variant from /opt/observium/mibs/ericsson.
Command help
Walk eriRouterOpticalTransceiverPortTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ERICSSON-ROUTER-OPTICAL-TRANSCEIVER-MIB' -M '/opt/observium/mibs/ericsson:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ERICSSON-ROUTER-OPTICAL-TRANSCEIVER-MIB::eriRouterOpticalTransceiverPortTable'
This table contains the ports with optical transceivers
and corresponding parameters
eriRouterOpticalTransceiverPortEntry row .1.3.6.1.4.1.193.218.2.50.1.1.1
Line Card port optical transceiver parameter
description.
Indexes
Column Syntax OID
The chassis slot number in which the card is
present where the Optical Transceiver plugged in.
ERICSSON-ROUTER-TCEriRouterSlot
Type Constraints:
range: 0..255
Description:
The chassis slot number. This is the physical slot
number as reported in the CLI command 'show hardware'
on SMS and the CLI command 'show port' on SE.
.1.3.6.1.4.1.193.218.2.50.1.1.1.1
The port number where the Optical Transceiver plugged in.
ERICSSON-ROUTER-TCEriRouterPort
Type Constraints:
range: 0..255
Description:
The chassis port number. This is the physical port
number as reported in the CLI command 'show hardware'
on SMS and the CLI command 'show port' on SE.
.1.3.6.1.4.1.193.218.2.50.1.1.1.2
Type and category of Optical Transceiver
OctetString
Constraints:
range: 0-255
.1.3.6.1.4.1.193.218.2.50.1.1.1.3
Optical Transceiver Media Type
OctetString
Constraints:
range: 0-255
.1.3.6.1.4.1.193.218.2.50.1.1.1.4
Is the Optical Transceiver n this port approved
by Ericsson, Yes/No?
SNMPv2-TCTruthValue
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.193.218.2.50.1.1.1.5
Is Optical Transceiver Diag Monitoring On or Off?
SNMPv2-TCTruthValue
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.193.218.2.50.1.1.1.6
Optical Transceiver Common Language Equipment Identifier (CLEI) code.
OctetString
Constraints:
range: 0-255
.1.3.6.1.4.1.193.218.2.50.1.1.1.7
Optical Transceiver serial number
OctetString
Constraints:
range: 0-255
.1.3.6.1.4.1.193.218.2.50.1.1.1.8
Optical Transceiver Frequency
OctetString
Constraints:
range: 0-255
.1.3.6.1.4.1.193.218.2.50.1.1.1.9
Optical Transceiver Wave Length
EriRouterOpticalTransceiverParamWaveLength
Type Constraints:
range: -1000000..1000000
Description:
Wave Length in NM in 1/100th
.1.3.6.1.4.1.193.218.2.50.1.1.1.10
Optical Transceiver Additional Features such as,
Is Optical Transceiver OTN capable?
and/or Is Optical Transceiver Tunable?
OctetString
Constraints:
range: 0-255
.1.3.6.1.4.1.193.218.2.50.1.1.1.11
Frequency Start for tunable optical transceiver.
Not applicable if optical transceiver is not tunable
OctetString
Constraints:
range: 0-255
.1.3.6.1.4.1.193.218.2.50.1.1.1.12
Frequency End for tunable optical transceiver.
Not applicable if optical transceiver is not tunable
OctetString
Constraints:
range: 0-255
.1.3.6.1.4.1.193.218.2.50.1.1.1.13
Frequency Spacing for tunable optical transceiver.
Not applicable if optical transceiver is not tunable
OctetString
Constraints:
range: 0-255
.1.3.6.1.4.1.193.218.2.50.1.1.1.14
Framer of OTN if optical transceiver is OTN capable.
Not applicable if optical transceiver is not OTN
capable
OctetString
Constraints:
range: 0-255
.1.3.6.1.4.1.193.218.2.50.1.1.1.15
FEC of OTN if optical transceiver is OTN capable.
Not applicable if optical transceiver is not OTN
capable
OctetString
Constraints:
range: 0-255
.1.3.6.1.4.1.193.218.2.50.1.1.1.16
Optical Transceiver Power Level
OctetString
Constraints:
range: 0-255
.1.3.6.1.4.1.193.218.2.50.1.1.1.17
Number of alarms active on the Optical Transceiver
SNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.193.218.2.50.1.1.1.18
This Bit Mask indicates which values are valid for
EriRouterOpticalTransceiverParamType in
eriRouterOpticalTransceiverParamTable:
0x0001 optical transceiver txpower valid
0x0002 optical transceiver rxpower valid…
SNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.193.218.2.50.1.1.1.19
Number of Lanes in optical transceiver
SNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.193.218.2.50.1.1.1.20
.1.3.6.1.4.1.193.218.2.50.1.2 · 1 row entry · 7 columns
Uses the ericsson variant from /opt/observium/mibs/ericsson.
Command help
Walk eriRouterOpticalTransceiverParamTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ERICSSON-ROUTER-OPTICAL-TRANSCEIVER-MIB' -M '/opt/observium/mibs/ericsson:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ERICSSON-ROUTER-OPTICAL-TRANSCEIVER-MIB::eriRouterOpticalTransceiverParamTable'
This table provides objects to monitor optical
transceiver parameters in a network element. It also
provides objects for monitoring high and low warning and
	alarm threshold on these monitored parameters.
eriRouterOpticalTransceiverParamEntry row .1.3.6.1.4.1.193.218.2.50.1.2.1
OpticalTransceiver Parameter Entries in Table
Column Syntax OID
This object specifies the optical parameter type that
is being monitored in this entry.
EriRouterOpticalTransceiverParamType
Type Values:
1txpower
2rxpower
3temperature
4laserBiasCurrent
5soaBiasCurrent
6vcc
7aux1
8aux2
Description:
Enums for optical transceiver parameters

txpower (1) : transmitter power
rxpower (2) : receiver power
temperature (3) : Temperature
laserBiasCurrent (4) : Laser bias current in 100s…
.1.3.6.1.4.1.193.218.2.50.1.2.1.1
This object specifies the optical parameter description including
units that is being monitored in this entry.
OctetString
Constraints:
range: 0-128
.1.3.6.1.4.1.193.218.2.50.1.2.1.2
The current value of tx power, rx power, temperature,
bias current and Vcc
EriRouterOpticalTransceiverParameterValue
Type Constraints:
range: -1000000..1000000
Description:
Tx power value or threshold value - unit milli dbm
Rx power value or threshold value - unit milli dbm
temperature value or threshold value - Represents a temperature,
in degrees Celsius (0..(100.0…
.1.3.6.1.4.1.193.218.2.50.1.2.1.3
The alarm high threshold value of tx power, rx power,
temperature, bias current and Vcc
EriRouterOpticalTransceiverParameterValue
Type Constraints:
range: -1000000..1000000
Description:
Tx power value or threshold value - unit milli dbm
Rx power value or threshold value - unit milli dbm
temperature value or threshold value - Represents a temperature,
in degrees Celsius (0..(100.0…
.1.3.6.1.4.1.193.218.2.50.1.2.1.4
The warning high threshold value of tx power, rx power,
temperature, bias current and Vcc
EriRouterOpticalTransceiverParameterValue
Type Constraints:
range: -1000000..1000000
Description:
Tx power value or threshold value - unit milli dbm
Rx power value or threshold value - unit milli dbm
temperature value or threshold value - Represents a temperature,
in degrees Celsius (0..(100.0…
.1.3.6.1.4.1.193.218.2.50.1.2.1.5
The alarm low threshold value of tx power, rx power,
temperature, bias current and Vcc
EriRouterOpticalTransceiverParameterValue
Type Constraints:
range: -1000000..1000000
Description:
Tx power value or threshold value - unit milli dbm
Rx power value or threshold value - unit milli dbm
temperature value or threshold value - Represents a temperature,
in degrees Celsius (0..(100.0…
.1.3.6.1.4.1.193.218.2.50.1.2.1.6
The warning low threshold value of tx power, rx power,
temperature, bias current and Vcc
EriRouterOpticalTransceiverParameterValue
Type Constraints:
range: -1000000..1000000
Description:
Tx power value or threshold value - unit milli dbm
Rx power value or threshold value - unit milli dbm
temperature value or threshold value - Represents a temperature,
in degrees Celsius (0..(100.0…
.1.3.6.1.4.1.193.218.2.50.1.2.1.7
.1.3.6.1.4.1.193.218.2.50.1.3 · 1 row entry · 7 columns
Uses the ericsson variant from /opt/observium/mibs/ericsson.
Command help
Walk eriRouterLaneInOpticalTransceiverParamTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ERICSSON-ROUTER-OPTICAL-TRANSCEIVER-MIB' -M '/opt/observium/mibs/ericsson:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ERICSSON-ROUTER-OPTICAL-TRANSCEIVER-MIB::eriRouterLaneInOpticalTransceiverParamTable'
This table provides objects to monitor optical
transceiver parameters in a network element. It also
provides objects for monitoring high and low  warning and
alarm threshold on these monitored parameters.
eriRouterLaneInOpticalTransceiverParamEntry row .1.3.6.1.4.1.193.218.2.50.1.3.1
LaneInOpticalTransceiver Parameter Entries in Table
Column Syntax OID
This object specifies the optical tranceiver lane that
is being monitored in this entry.
Integer32
Constraints:
range: 1-16
.1.3.6.1.4.1.193.218.2.50.1.3.1.1
This object specifies the optical parameter type that
is being monitored in this entry.
EriRouterLaneInOpticalTransceiverParamType
Type Values:
1laneTxPower
2laneRxPower
3laneTemperature
4laneLaserBiasCurrent
Description:
Enums for optical transceiver parameters

laneTxPower (1) : transmitter power
laneRxPower (2) : receiver power
laneTemperature (3) : Temperature
laneLaserBiasCurrent (4) : Laser bi…
.1.3.6.1.4.1.193.218.2.50.1.3.1.2
The current value of tx power, rx power, temperature,
bias current and Vcc
EriRouterLaneInOpticalTransceiverParameterValue
Type Constraints:
range: -1000000..1000000
Description:
Tx power range - unit milli dbm
Rx power range - unit milli dbm
temperature range - Represents a temperature,
in degrees Celsius (0..(100.000))
Bias Current Range - unit 100s of microamperes
.1.3.6.1.4.1.193.218.2.50.1.3.1.3
The alarm high threshold value of tx power, rx power,
temperature, bias current and Vcc
EriRouterLaneInOpticalTransceiverParameterValue
Type Constraints:
range: -1000000..1000000
Description:
Tx power range - unit milli dbm
Rx power range - unit milli dbm
temperature range - Represents a temperature,
in degrees Celsius (0..(100.000))
Bias Current Range - unit 100s of microamperes
.1.3.6.1.4.1.193.218.2.50.1.3.1.4
The warning high threshold value of tx power, rx power,
temperature, bias current and Vcc
EriRouterLaneInOpticalTransceiverParameterValue
Type Constraints:
range: -1000000..1000000
Description:
Tx power range - unit milli dbm
Rx power range - unit milli dbm
temperature range - Represents a temperature,
in degrees Celsius (0..(100.000))
Bias Current Range - unit 100s of microamperes
.1.3.6.1.4.1.193.218.2.50.1.3.1.5
The alarm low threshold value of tx power, rx power,
temperature, bias current and Vcc
EriRouterLaneInOpticalTransceiverParameterValue
Type Constraints:
range: -1000000..1000000
Description:
Tx power range - unit milli dbm
Rx power range - unit milli dbm
temperature range - Represents a temperature,
in degrees Celsius (0..(100.000))
Bias Current Range - unit 100s of microamperes
.1.3.6.1.4.1.193.218.2.50.1.3.1.6
The warning low threshold value of tx power, rx power,
temperature, bias current and Vcc
EriRouterLaneInOpticalTransceiverParameterValue
Type Constraints:
range: -1000000..1000000
Description:
Tx power range - unit milli dbm
Rx power range - unit milli dbm
temperature range - Represents a temperature,
in degrees Celsius (0..(100.000))
Bias Current Range - unit 100s of microamperes
.1.3.6.1.4.1.193.218.2.50.1.3.1.7