docsIfUpChannelFrequency
DOCS-IF-MIB ·
.1.3.6.1.2.1.10.127.1.1.2.1.2
Object
column r/w
hertzInteger32
The center of the frequency band associated with this upstream interface. This object returns 0 if the frequency is undefined or unknown. Minimum permitted upstream frequency is 5,000,000 Hz for current technology. See the associated conformance object for write conditions and limitations.
Context
- MIB
- DOCS-IF-MIB
- OID
.1.3.6.1.2.1.10.127.1.1.2.1.2- Type
- column
- Access
- readwrite
- Status
- current
- Units
- hertz
- Parent
- docsIfUpstreamChannelEntry
- Groups
- 2
Net-SNMP examples
How SNMP and these commands workWalk the column to discover its indexed instances, or supply every index to read one instance.
Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'DOCS-IF-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'DOCS-IF-MIB::docsIfUpChannelFrequency'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'DOCS-IF-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'DOCS-IF-MIB::docsIfUpChannelFrequency.<ifIndex>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'DOCS-IF-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'DOCS-IF-MIB::docsIfUpChannelFrequency'
Syntax
hertzInteger32
Values & Constraints
Object Constraints
range: 0-1000000000
Conformance
Member of
Compliance refinements
docsIfBasicCompliance
readonly
Read-write in cable modem termination systems;
read-only in cable modems. The values above are
appropriate for a cable plant using a Sub-Split channel
plan. If DOCSIS is extended to cover other types of
channel plans (and frequency allocations), this object
will be modified accordingly.
read-only in cable modems. The values above are
appropriate for a cable plant using a Sub-Split channel
plan. If DOCSIS is extended to cover other types of
channel plans (and frequency allocations), this object
will be modified accordingly.
docsIfBasicComplianceV2
readonly
Read-create in cable modem termination systems;
read-only in cable modems.
A range of 5MHz to 42MHz is appropriate for a cable
plant using a North American Sub-Split channel plan.
The spectrum range has been expanded to accommodate
an upper edge of 65MHz for some European channel plans.
If DOCSIS is extended to cover other types of channel
plans (and frequency allocations), this object will
be modified accordingly.
read-only in cable modems.
A range of 5MHz to 42MHz is appropriate for a cable
plant using a North American Sub-Split channel plan.
The spectrum range has been expanded to accommodate
an upper edge of 65MHz for some European channel plans.
If DOCSIS is extended to cover other types of channel
plans (and frequency allocations), this object will
be modified accordingly.