docsIfUpChannelCloneFrom

DOCS-IF-MIB · .1.3.6.1.2.1.10.127.1.1.2.1.16

Object

This object contains the ifIndex value of the physical
interface row entry whose parameters are to be adjusted.
              
Upon setting this object to the ifIndex value of a
physical interface, the following interface objects values
are copied to this entry:
docsIfUpChannelFrequency,
docsIfUpChannelWidth,
docsIfUpChannelModulationProfile,
docsIfUpChannelSlotSize,
docsIfUpChannelRangingBackoffStart,
docsIfUpChannelRangingBackoffEnd,
docsIfUpChannelTxBackoffStart,
docsIfUpChannelTxBackoffEnd,
docsIfUpChannelScdmaActiveCodes,
docsIfUpChannelScdmaCodesPerSlot,
docsIfUpChannelScdmaFrameSize,
docsIfUpChannelScdmaHoppingSeed,
docsIfUpChannelType, and
docsIfUpChannelPreEqEnable
Setting this object to the value of a non-existent or
a temporary upstream interface returns the error
'wrongValue'.
This object MUST contain a value of zero for physical
interfaces entries.
Setting this object in row entries that correspond to
physical interfaces returns the error 'wrongValue'.

Context

MIB
DOCS-IF-MIB
OID
.1.3.6.1.2.1.10.127.1.1.2.1.16
Type
column
Access
readwrite
Status
current
Parent
docsIfUpstreamChannelEntry
Groups
1

Walk the column to discover its indexed instances, or supply every index to read one instance.

Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'DOCS-IF-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'DOCS-IF-MIB::docsIfUpChannelCloneFrom'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'DOCS-IF-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'DOCS-IF-MIB::docsIfUpChannelCloneFrom.<ifIndex>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'DOCS-IF-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'DOCS-IF-MIB::docsIfUpChannelCloneFrom'

Syntax

Source
IF-MIBInterfaceIndexOrZero
Base type
Integer32
Display format
d
Type Description
This textual convention is an extension of the
InterfaceIndex convention.  The latter defines a greater
than zero value used to identify an interface or interface
sub-layer in the managed system.  This extension permits the
additional value of zero.  the value zero is object-specific
and must therefore be defined as part of the description of
any object which uses this syntax.  Examples of the usage of
zero might include situations where interface was unknown,
or when none or all interfaces need to be referenced.

Values & Constraints

Type Constraints
range: 0..2147483647

Conformance

Member of
Compliance refinements
Read-create in cable modem termination systems;