dsx3NEAlarmUpCount
CISCO-MGX82XX-DSX3-MIB ·
.1.3.6.1.4.1.351.110.4.4.1.2.1.1.3
Object
column
r/w
Integer32
This parameter specifies the increment to the
Near End alarm integration counters. The local
alarms are LOS and LOF. The Default value is 6
and the integration counter is incremented by
this value every 10 ms while the alarm persists.
The counter is decremented by the value of
dsx3NEAlarmDnCount while there is no alarm
(the counter does not decrement below zero).
When the integration counter exceeds
dsx3NEAlarmThreshold an Alarm of the severity
specified for the particular NE alarm is declared.
LOF detection is not applicable for CESM-T3/E3
Context
- MIB
- CISCO-MGX82XX-DSX3-MIB
- OID
.1.3.6.1.4.1.351.110.4.4.1.2.1.1.3- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- dsx3AlarmConfigEntry
Syntax
Integer32
Values & Constraints
Object Constraints
range: 0-2147483647