dsx3NEAlarmDownCount

CISCO-MGX82XX-DSX3-MIB · .1.3.6.1.4.1.351.110.4.4.1.2.1.1.4

Object

column r/w Integer32
This parameter specifies the decrement to the 
Near End alarm integration counters. The local 
alarms are LOS and LOF. The Default value is 1 and 
the integration counter is decremented by this value 
every 10 ms while no alarm persists. The counter is 
incremented by the value of dsx3NEAlarmUpCount
while there is no alarm (the counter does not decrement below
zero). When the integration counter reaches zero any Alarm
previously declared is removed.
              
LOF detection is not applicable for CESM-T3/E3

Context

MIB
CISCO-MGX82XX-DSX3-MIB
OID
.1.3.6.1.4.1.351.110.4.4.1.2.1.1.4
Type
column
Access
readwrite
Status
current
Parent
dsx3AlarmConfigEntry
Table
dsx3AlarmConfigTable
Siblings
38

Syntax

Integer32

Values & Constraints

Object Constraints
range: 0-2147483647

Related Objects

Sibling Objects