ciscoEnvMonVoltageThresholdLow

OBS ✓
CISCO-ENVMON-MIB · .1.3.6.1.4.1.9.9.13.1.2.1.4

Object

column millivoltsSNMPv2-SMIInteger32
The lowest value that the associated instance of the object
ciscoEnvMonVoltageStatusValue may obtain before an emergency
shutdown of the managed device is initiated.
Observium directly uses this object
This object is referenced by an Observium discovery or polling workflow.
Used in: Sensors
Explore Observium network monitoring

Context

MIB
CISCO-ENVMON-MIB
OID
.1.3.6.1.4.1.9.9.13.1.2.1.4
Type
column
Access
readonly
Status
current
Units
millivolts
Parent
ciscoEnvMonVoltageStatusEntry
Groups
2

Walk the column to discover its indexed instances, or supply every index to read one instance.

Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-ENVMON-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-ENVMON-MIB::ciscoEnvMonVoltageThresholdLow'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'CISCO-ENVMON-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-ENVMON-MIB::ciscoEnvMonVoltageThresholdLow.<ciscoEnvMonVoltageStatusIndex>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'CISCO-ENVMON-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'CISCO-ENVMON-MIB::ciscoEnvMonVoltageThresholdLow'

Syntax

Source
SNMPv2-SMIInteger32
Base type
Integer32

Values & Constraints

Type Constraints
range: -2147483648..2147483647