.1.3.6.1.4.1.9.9.13.1.2 · 1 row entry · 7 columns
Uses the cisco variant from /opt/observium/mibs/cisco.
Command help
Walk ciscoEnvMonVoltageStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-ENVMON-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-ENVMON-MIB::ciscoEnvMonVoltageStatusTable'
The table of voltage status maintained by the environmental
monitor.
ciscoEnvMonVoltageStatusEntry row .1.3.6.1.4.1.9.9.13.1.2.1
An entry in the voltage status table, representing the status
of the associated testpoint maintained by the environmental
monitor.
Column Syntax OID
Unique index for the testpoint being instrumented.
This index is for SNMP purposes only, and has no
intrinsic meaning.
Integer32
Constraints:
range: 0-2147483647
.1.3.6.1.4.1.9.9.13.1.2.1.1
Textual description of the testpoint being instrumented.
This description is a short textual label, suitable as a
human-sensible identification for the rest of the
information in the entry.
OctetString
Constraints:
range: 0-32
.1.3.6.1.4.1.9.9.13.1.2.1.2
The current measurement of the testpoint being instrumented.
millivoltsCiscoSignedGauge .1.3.6.1.4.1.9.9.13.1.2.1.3
The lowest value that the associated instance of the object
ciscoEnvMonVoltageStatusValue may obtain before an emergency
shutdown of the managed device is initiated.
millivoltsSNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.9.9.13.1.2.1.4
The highest value that the associated instance of the object
ciscoEnvMonVoltageStatusValue may obtain before an emergency
shutdown of the managed device is initiated.
millivoltsSNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.9.9.13.1.2.1.5
The value of the associated instance of the object
ciscoEnvMonVoltageStatusValue at the time an emergency
shutdown of the managed device was last initiated. This
value is stored in non-volatile RAM and hence is able to…
millivoltsSNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.9.9.13.1.2.1.6
The current state of the testpoint being instrumented.
CiscoEnvMonState
Type Values:
1normal
2warning
3critical
4shutdown
5notPresent
6notFunctioning
.1.3.6.1.4.1.9.9.13.1.2.1.7
.1.3.6.1.4.1.9.9.13.1.3 · 1 row entry · 7 columns
Uses the cisco variant from /opt/observium/mibs/cisco.
Command help
Walk ciscoEnvMonTemperatureStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-ENVMON-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-ENVMON-MIB::ciscoEnvMonTemperatureStatusTable'
The table of ambient temperature status maintained by the
environmental monitor.
ciscoEnvMonTemperatureStatusEntry row .1.3.6.1.4.1.9.9.13.1.3.1
An entry in the ambient temperature status table, representing
the status of the associated testpoint maintained by the
environmental monitor.
Column Syntax OID
Unique index for the testpoint being instrumented.
This index is for SNMP purposes only, and has no
intrinsic meaning.
Integer32
Constraints:
range: 0-2147483647
.1.3.6.1.4.1.9.9.13.1.3.1.1
Textual description of the testpoint being instrumented.
This description is a short textual label, suitable as a
human-sensible identification for the rest of the
information in the entry.
OctetString
Constraints:
range: 0-32
.1.3.6.1.4.1.9.9.13.1.3.1.2
The current measurement of the testpoint being instrumented.
The object ciscoEnvMonTemperatureStatusValueRev1 should be
used to read the temperature.
degrees CelsiusSNMPv2-SMIGauge32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.9.9.13.1.3.1.3
The highest value that the associated instance of the
object ciscoEnvMonTemperatureStatusValueRev1 may obtain
before an emergency shutdown of the managed device is
initiated.
degrees CelsiusSNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.9.9.13.1.3.1.4
The value of the associated instance of the object
ciscoEnvMonTemperatureStatusValueRev1 at the time an emergency
shutdown of the managed device was last initiated. This
value is stored in non-volatile RAM and hence is…
degrees CelsiusSNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.9.9.13.1.3.1.5
The current state of the testpoint being instrumented.
CiscoEnvMonState
Type Values:
1normal
2warning
3critical
4shutdown
5notPresent
6notFunctioning
.1.3.6.1.4.1.9.9.13.1.3.1.6
The current measurement of the testpoint being instrumented.It also
accomodates negative temperature values.
degrees CelsiusSNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.9.9.13.1.3.1.7
.1.3.6.1.4.1.9.9.13.1.4 · 1 row entry · 3 columns
Uses the cisco variant from /opt/observium/mibs/cisco.
Command help
Walk ciscoEnvMonFanStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-ENVMON-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-ENVMON-MIB::ciscoEnvMonFanStatusTable'
The table of fan status maintained by the environmental
monitor.
ciscoEnvMonFanStatusEntry row .1.3.6.1.4.1.9.9.13.1.4.1
An entry in the fan status table, representing the status of
the associated fan maintained by the environmental monitor.
Column Syntax OID
Unique index for the fan being instrumented.
This index is for SNMP purposes only, and has no
intrinsic meaning.
Integer32
Constraints:
range: 0-2147483647
.1.3.6.1.4.1.9.9.13.1.4.1.1
Textual description of the fan being instrumented.
This description is a short textual label, suitable as a
human-sensible identification for the rest of the
information in the entry.
OctetString
Constraints:
range: 0-32
.1.3.6.1.4.1.9.9.13.1.4.1.2
The current state of the fan being instrumented.
CiscoEnvMonState
Type Values:
1normal
2warning
3critical
4shutdown
5notPresent
6notFunctioning
.1.3.6.1.4.1.9.9.13.1.4.1.3
.1.3.6.1.4.1.9.9.13.1.5 · 1 row entry · 4 columns
Uses the cisco variant from /opt/observium/mibs/cisco.
Command help
Walk ciscoEnvMonSupplyStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-ENVMON-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-ENVMON-MIB::ciscoEnvMonSupplyStatusTable'
The table of power supply status maintained by the
environmental monitor card.
ciscoEnvMonSupplyStatusEntry row .1.3.6.1.4.1.9.9.13.1.5.1
An entry in the power supply status table, representing the
status of the associated power supply maintained by the
environmental monitor card.
Column Syntax OID
Unique index for the power supply being instrumented.
This index is for SNMP purposes only, and has no
intrinsic meaning.
Integer32
Constraints:
range: 0-2147483647
.1.3.6.1.4.1.9.9.13.1.5.1.1
Textual description of the power supply being instrumented.
This description is a short textual label, suitable as a
human-sensible identification for the rest of the
information in the entry.
OctetString
Constraints:
range: 0-32
.1.3.6.1.4.1.9.9.13.1.5.1.2
The current state of the power supply being instrumented.
CiscoEnvMonState
Type Values:
1normal
2warning
3critical
4shutdown
5notPresent
6notFunctioning
.1.3.6.1.4.1.9.9.13.1.5.1.3
The power supply source.
unknown - Power supply source unknown
ac - AC power supply
dc - DC power supply
externalPowerSupply - External power supply
internalRedundant - Internal redundant power supply
Enumeration
Enumerated Values:
1unknown
2ac
3dc
4externalPowerSupply
5internalRedundant
.1.3.6.1.4.1.9.9.13.1.5.1.4