cApsConfigSwitchoverEnableInterval
CISCO-APS-EXT-MIB ·
.1.3.6.1.4.1.9.10.72.1.2.1.5
Object
column
r/w
seconds Integer32
This object specifies the value of the timer to control the minimum interval between switchovers. After a switchover, APS is re-enabled only after this amount of time has elapsed, in order to prevent quick successive switchovers.
Context
- MIB
- CISCO-APS-EXT-MIB
- OID
.1.3.6.1.4.1.9.10.72.1.2.1.5- Type
- column
- Access
- readwrite
- Status
- current
- Units
- seconds
- Parent
- cApsConfigExtEntry
Syntax
seconds Integer32
Values & Constraints
Object Constraints
range: 1-120